1 trong số 1

Beckhoff CX2550-0279 CX2000 Series USB Extender 2.0 Transmitter Module

Beckhoff CX2550-0279 CX2000 Series USB Extender 2.0 Transmitter Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX2550-0279

  • Country of origin:Đức

  • Product Type: USB Extender Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 24 mm x 99 mm x 54.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The Beckhoff CX2550-0279 functions as a direct system-bus expansion module designed for CX20xx Embedded PCs, enabling remote USB 2.0 signal transmission up to 50 meters. This transmitter module mounts directly to the left-hand side of a CX20xx CPU block, converting standard internal USB lines into a serialized differential signal suitable for long-distance runs over standard Ethernet-style physical media. This setup is specifically optimized for connecting control panels such as the CP29xx-0000 series without signal degradation or latency spikes, ensuring seamless peripheral integration in complex industrial environments.

Key Features

  • Dedicated 1 x USB Extended 2.0 interface utilizing a rugged RJ45 connection port.
  • Reliable signal extension up to a maximum distance of 50 meters over standard Cat.5E or higher shielded cabling.
  • Native system bus integration drawing power directly through preceding CX2100-0xxx power supply units.
  • On-board LED diagnostic indicators for real-time status validation (Power, Host, Activity, and Link status).
  • Compact 24 mm form factor designed for high-density DIN-rail mounting configurations.

Applications

  • Connecting decentralized HMI and operator screens (CP29xx-0000 series) in scattered manufacturing cells.
  • Extending USB diagnostic interfaces outside enclosed, high-voltage electrical panels.
  • Facilitating clean wiring routing in modern modular production lines and material handling facilities.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Number CX2550-0279
Interface Type 1 x USB Extended 2.0 (via RJ45 socket)
Maximum Cable Length 50 meters (using Cat.5E cabling)
Power Feed Via system bus (through CX2100-0xxx modules)
LED Diagnostics Power (1x), Host (1x), Activity (1x), Link (1x)
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Weight Approximately 190 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Port Type Connector Pinout / LED Signal Description
RJ45 Output Port Pins 1 to 8 Differential USB transmission pairs over Cat.5E shielded line. Do not connect to Ethernet switches.
LED: PWR On (Green) Internal system power is successfully applied via the system bus.
LED: HOST On (Green) Established connection with the primary CX20xx CPU host interface.
LED: LINK On (Green) Active connection established with the remote CP29xx receiver.

Empirical Engineering Insights

Alternative Models & Compatibility

This module behaves specifically as a Point-to-Point Transmitter (Tx) and must be paired with an appropriate receiver, typically integrated directly into Beckhoff CP29xx-0000 Control Panels or external receiver boxes. It is physically designed to slide and snap into place on the left-side expansion slot of the CX20xx series. Ensure your CPU configuration in TwinCAT recognizes the additional module on the PC-system bus before commissioning.

Application Pitfalls & Engineering Notes

A common error on-site is treating the physical RJ45 interface on the front of this unit as an Ethernet network port. Patching this connection into a standard LAN switch, router, or hub can cause immediate electrical damage to either the network hardware or the internal transceiver circuitry of the controller. Keep the extension path strictly point-to-point.

Commissioning & Wiring Tips

For transmissions reaching near the 50-meter limit, always use high-quality, double-shielded copper cabling (S/FTP Cat.5E or Cat.6). Avoid routing this physical-layer run in close proximity to high-frequency variable frequency drive (VFD) output cables or high-voltage lines, as noise coupling on the differential lines can cause momentary dropouts in panel mouse/keyboard and touch signals.

Installation Guidelines

CRITICAL WARNING: Prior to snapping this expansion unit onto the CX20xx CPU module or altering any interface cables, ensure the entire controller rack and any connected remote displays are completely powered down. Verify that no residual voltages are present in the power supply line. Failure to de-energize can damage sensitive differential transceiver chips on the system bus.
1
Align the male multi-pin system-bus connector of the CX2550-0279 with the left-side female interface of the CX20xx CPU unit. Ensure the DIN-rail locking clips are pulled out.
2
Press the module firmly into place until you hear it click, securing it to the adjacent CPU module. Push the DIN-rail locking clips back in to anchor the module on the DIN rail.
3
Insert your dedicated Cat.5E shielded line into the front RJ45 socket and route directly to the panel receiver module, keeping it separate from high-interference power lines.

Can I connect this transmitter directly to a standard network switch or router?

No. The RJ45 interface uses a specialized proprietary physical layer to transmit differential USB signals. Connecting this port to an Ethernet switch or network device can damage the internal components of both units.

What is the maximum cable length supported by this module?

The module supports point-to-point connections up to a maximum distance of 50 meters. To reach this distance, use high-quality shielded Cat.5E or Cat.6 cabling.

Where does this module receive its operating power?

The device draws its power directly from the system bus connected to the adjacent CPU block, which is powered through standard CX2100-0xxx power supply units.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...