Description

To facilitate distributed decentralized I/O acquisition in harsh industrial environments, the Beckhoff IP2300-B510 integrates discrete inputs and outputs directly at the machine level via a high-performance CANopen fieldbus interface. This compact Fieldbus Box module features 4 digital inputs with a 3 ms input filter alongside 4 digital outputs rated for 0.5 A, housing them within an IP67-rated enclosure designed to bypass the need for protective control cabinets. Connection is established using space-saving M8 connector sockets, minimizing cabling overhead and reducing transmission latency in decentralized automation topologies.

Features

  • Direct integration into CANopen industrial networks via standard D-sub or M12 connection interfaces.
  • Robust IP67 housing design, rendering the unit fully resistant to dust, moisture, and high-pressure washdown environments.
  • Four integrated 24 V DC digital inputs featuring an integrated 3 ms hardware input filter to suppress signal contact bounce.
  • Four short-circuit proof 24 V DC digital outputs capable of delivering up to 0.5 A continuous current per channel.
  • Diagnostic LEDs mapping network activity, device operational status, and localized channel diagnostics.
  • Simple rotary address switches for rapid node address configuration during commissioning.

Applications

  • Automotive assembly lines and robotic tool-end I/O processing.
  • Conveyor networks and packaging machinery requiring decentralized, machine-mount sensor consolidation.
  • Material handling plants utilizing distributed CANopen topologies.
  • Machine tool control lines subject to high coolant, oil, or particulate exposure.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Identifier IP2300-B510
Fieldbus System CANopen
Digital Inputs 4 channels (24 V DC)
Input Filter Time 3.0 ms
Digital Outputs 4 channels (24 V DC, short-circuit proof)
Max. Output Current 0.5 A per channel (total current limits apply)
I/O Connection Type M8 (diameter 8 mm circular connectors)
Operating Voltage 24 V DC (control and load voltage feeds)
Ingress Protection Rating IP67 (when all slots are mated or capped)
Operating Temperature Range 0 to 55 degC
Storage Temperature Range -25 to 85 degC
Shipping Weight (Calculated) 2.0 kg
Package Dimensions (Calculated) 220 mm x 110 mm x 60 mm

Connections and Interfaces

M8 Connector Pin Input Port Assignment Output Port Assignment
Pin 1 +24 V DC Sensor Supply Not Connected
Pin 2 Not Connected Auxiliary Ground Reference
Pin 3 GND Sensor Supply GND Load Supply
Pin 4 Digital Input Signal (DI1 to DI4) Digital Output Signal (DO1 to DO4)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2300-B510 utilizes standard CANopen communication profiles. While mechanically identical to the IP2300-B310 (PROFIBUS DP) and IP2300-B900 (Ethernet), it requires a dedicated CANopen master or coupler to map PDOs/SDOs. If migrating from older legacy Beckhoff Fieldbus Box units, verify your network master's ESD (electronic data sheet) configuration files to ensure parameter mappings match the device profile.

Application Pitfalls & Engineering Notes

When deploying in wet or high-humidity environments, any unused M8 ports must be covered using IP67-rated protective caps. Leaving even a single port exposed compromises the environmental seal of the entire assembly, leading to moisture ingress and localized internal short circuits between the 24 V DC sensor supply line and ground.

Commissioning & Wiring Tips

Ensure that the CANopen network is terminated with a 120-Ohm resistor at both ends of the physical bus. If the IP2300-B510 is configured as the physical end-of-line node, a dedicated terminating M12 plug must be inserted. Always set the node ID via the address dial switches under the protective screw cap prior to powering on the control logic feed.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources (logic and field power loops) before mounting, cabling, or adjusting the address switches. Ground loops can induce network dropouts and permanently degrade the integrated output transistors.

1
Mount the IP2300-B510 module directly onto a flat, vibration-resistant machine frame using M4 mounting screws. Connect the chassis ground contact to the machine frame.
2
Set the designated CANopen node address and communication baud rate using the rotary switches under the front protective cover. Reseal the cover tightly.
3
Attach the M8 sensor and actuator cables, ensuring a secure thread lock is achieved on each connector to protect against moisture intrusion.
4
Connect the incoming CANopen network cable and power lines. Turn on the 24 V DC system logic and perform testing sequences via your PLC's network master.

What fieldbus protocol does the IP2300-B510 module utilize?

The IP2300-B510 operates using the CANopen communication protocol, allowing integration into standard CAN networks with flexible baud rate configurations.

What is the ingress protection rating of the IP2300-B510 box?

It is rated IP67, making it completely dust-tight and resistant to water immersion, provided all unused M8 and M12 connection ports are properly sealed with protective caps.

Can I output more than 0.5 A from the digital output channels?

No, the digital outputs are rated for a maximum of 0.5 A per channel. Drawing more current will trigger the integrated short-circuit protection mechanism.

How are the device nodes and communication speed set?

The CANopen node ID and baud rate parameters are manually configured using rotary switches located underneath the protective front screw cap.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...