Beckhoff KL4022 Bus Terminal 2-Channel Analog Output Module

Beckhoff KL4022 Bus Terminal 2-Channel Analog Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL4022

  • Country of origin:Đức

  • Product Type: Analog Output Modules

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed for integration into standard K-bus networks, the Beckhoff KL4022 enables high-precision processing of current loop control signals. This terminal converts 12-bit digital values from the automation controller into isolated analog current outputs within the standard 4 to 20 mA range. Its single-ended topology, compact housing, and low conversion latency make it highly suitable for demanding industrial actuator control, valve positioning, and motor drive setpoint configuration.

Features

  • Dual-channel analog output configuration utilizing single-ended common ground architecture.
  • Robust 12-bit digital-to-analog conversion delivering dependable loop precision.
  • High-integrity electrical isolation of 500 V between the internal K-bus and field signals.
  • Rapid internal conversion sequence with a typical processing time of 1.5 milliseconds.
  • Efficient power distribution leveraging integrated 24 V DC power contacts on the backplane.

Applications

  • Electro-pneumatic and electro-hydraulic proportional valve positioners.
  • Frequency inverter and variable speed drive (VSD) speed references.
  • Distributed SCADA and process control instrumentation interfaces.
  • Industrial boiler and heating element loop controller feedback.

Technical Specifications

Parameter Value / Rating
Manufacturer Beckhoff Automation
Model Number KL4022
Signal Range 4 to 20 mA
Number of Channels 2
Resolution 12-bit
Load Impedance Less than 500 Ohm
Conversion Time approx. 1.5 ms
Output Error Less than +/- 0.1% (relative to full-scale value)
Power Supply 24 V DC via power contacts (or 15 V DC via KL9515 supply terminal)
K-Bus Current Consumption typ. 75 mA
Electrical Isolation 500 V (K-bus / signal voltage)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Country of Origin Germany
Weight approx. 80 g
Shipping Weight (Calculated) 0.25 kg

Connections and Interfaces

Terminal Point Signal Assignment Description
1 OUT 1 Analog Output Channel 1 (+)
5 0V (1) Analog Output Channel 1 ground (-)
2 OUT 2 Analog Output Channel 2 (+)
6 0V (2) Analog Output Channel 2 ground (-)
3 +24 V Power Contact Connection (+24 V DC)
7 0 V Power Contact Connection (0 V DC)
4 Shield Shield contact point (connected to DIN rail)
8 Shield Shield contact point (connected to DIN rail)

Empirical Engineering Insights

Alternative Models & Compatibility

The KL4022 utilizes Beckhoff's legacy K-bus backplane communication system. If transitioning to an EtherCAT infrastructure, the direct equivalent is the EL4022. Note that EL-series terminals utilize the E-bus and cannot reside on standard KL-series couplers (e.g., BK9000, BK3120) without active E-bus/K-bus converter couplers.

Application Pitfalls & Engineering Notes

Since the KL4022 is a single-ended terminal sharing a common internal ground loop, noise injected into the 0 V signal reference on one loop can cause cross-talk or offset drift on the secondary channel. For field installations with significant ground potential differences, isolated signal conditioning barriers must be installed between the KL4022 and the end-actuator to prevent loop degradation.

Commissioning & Wiring Tips

Ensure that shielding is correctly terminated. Terminal points 4 and 8 are connected to the mounting rail. To guarantee sufficient noise rejection, the standard 35 mm DIN rail must be connected to the central control cabinet ground with low-impedance copper braided strap. Ensure K-bus power contacts are adequately populated with 24 V DC; voltage drops below 18 V DC will cause conversion errors or terminal fault signals within TwinCAT.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Isolate and lock out all power supplies to the system before inserting or removing K-bus components. Modifying the physical configuration or terminal assembly while the power is active can induce voltage spikes, resulting in damage to the internal bus driver circuitry or physical terminal contacts.

1

Mount the terminal onto the 35 mm DIN rail (EN 60715) by sliding the terminal's rear slot onto the rail guide until the locking tab audibly clicks.

2

Align the terminal laterally with the adjacent Bus Terminal block to engage the tongue-and-groove joint and establish continuous electrical contact via the side-mounted gold contacts.

3

Insert field connection cables into the cage-clamp connectors using an appropriate industrial screwdriver. Release the mechanism to secure wire connection.

4

Connect the analog loop shielding directly to contacts 4 or 8 to guarantee direct path grounding through the DIN rail structure.

What is the key difference between the KL4022 and EL4022 modules?

The KL4022 operates on the K-bus backplane protocol for classic bus couplers, whereas the EL4022 communicates via E-bus for EtherCAT networks. They cannot be placed on the same terminal strip without a dedicated converter terminal.

Does this terminal require an external loop power supply for the current signal?

The KL4022 extracts its power from the integrated 24 V DC power contacts. If the power Contacts are not energized, or if isolation is required, you must insert a power supply terminal like the KL9100 or KL9200 immediately to its left.

How is the 12-bit resolution represented inside the controller software?

The 12-bit value is loaded into a 16-bit register as a left-aligned integer. The remaining 4 least-significant bits are ignored by the internal digital-to-analog converter.

Are the two output channels of the KL4022 electrically isolated from each other?

No, both channels share a common internal ground reference (0 V) and are single-ended. However, they are both electrically isolated up to 500 V from the K-bus logic circuitry.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...