Beckhoff KS3064 Bus Terminal 4-Channel Analog Input Module

Beckhoff KS3064 Bus Terminal 4-Channel Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS3064

  • Country of origin:Đức

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 80g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

To facilitate precise voltage acquisition in dense processing environments, the Beckhoff KS3064 analog input terminal digitizes field-side signals from 0 to 10 V DC with 12-bit resolution. As part of the premium pluggable KSxxxx series, this 4-channel single-ended module integrates highly reliable performance with a hot-swappable terminal block design, enabling quick hardware change-outs without disturbing existing field wiring. It communicates directly with the primary industrial controller via the standard K-bus interface, combining high processing efficiency with minimal space requirements.

Features

  • Four Single-Ended Inputs: Allows simultaneous monitoring of four independent 0 to 10 V analog signals.
  • Pluggable Wiring Interface: Front-facing tension-clamp connector block is easily removable, reducing maintenance downtime and simplifying cabinet retrofits.
  • 12-Bit Analog-to-Digital Conversion: Delivers sharp resolution for highly accurate PLC and DCS monitoring applications.
  • Galvanic Isolation: Provides robust 500 V electrical isolation between the internal K-bus and the process circuitry, defending control hardware from voltage spikes.
  • Compact 12 mm Footprint: Modular housing saves valuable DIN-rail space inside control panels.

Applications

  • Process Sensor Monitoring: Acquires signal inputs from flow meters, pressure transmitters, and distance sensors.
  • HVAC Control Integration: Collects temperature and humidity voltage signals from environmental monitoring units.
  • Machinery Control Platforms: Acts as the analog interface for OEM assembly equipment, handling variable system feedback.

Technical Specifications

Specification Parameter Value / Detail
Manufacturer Beckhoff
Model Number KS3064
Module Type 4-Channel Analog Input (Single-Ended)
Signal Voltage Range 0 to 10 V DC
Internal Resistance > 200 kOhm (typical)
Resolution 12 bit
Conversion Time Approx. 4 ms
Measuring Error < +/- 0.3 % (relative to full scale value)
K-Bus Current Consumption Typ. 85 mA
Electrical Isolation 500 V (K-bus / signal voltage)
Connection Method Pluggable spring-actuated terminal block
Connection Cross-Section Solid/Stranded: 0.08 to 1.5 mm2 (AWG 28 to 16)
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Protection Class IP20
Ex Marking II 3 G Ex nA IIC T4 Gc (ATEX certified)
Country of Origin Germany
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Unit Weight 0.08 kg

Connections & Interfaces

Terminal Pin Number Signal Type Description
1 Input 1 (+) Voltage input channel 1 (0 to 10 V)
5 Input 2 (+) Voltage input channel 2 (0 to 10 V)
2 Input 3 (+) Voltage input channel 3 (0 to 10 V)
6 Input 4 (+) Voltage input channel 4 (0 to 10 V)
3, 7, 4, 8 Common GND Internal common reference ground points (0 V)

Empirical Engineering Insights

Alternative Models & Compatibility

The KS3064 functions identically to the standard KL3064 Bus Terminal. The critical system-level distinction is the physical terminal interface; the KS3064 employs a pluggable terminal system, while the KL3064 utilizes fixed tension clamps. Both share exact software mappings in TwinCAT 2 and TwinCAT 3 systems. If replacing a KL3064, no modifications are required within the PLC configuration.

Application Pitfalls & Engineering Notes

Because this is a single-ended terminal, all 4 input channels share a common internal ground reference linked directly to the system's external ground. If integrating transmitter signals sourced from different, isolated field power supplies, any potential offsets between the power supplies will introduce measurement offset errors. To preserve the 12-bit measurement integrity, ensure that all sensor reference grounds are bonded to a common equipotential earth system.

Commissioning & Wiring Tips

Analog signals in the 0 to 10 V range are highly susceptible to high-frequency electromagnetic interference from surrounding VFDs and power contacts. It is vital to use shielded twisted-pair cabling. Always ground the signal shield only at the central control cabinet ingress plate rather than terminating the shield to the terminal blocks, to avoid creating ground loop currents across the internal K-bus.

Installation Guidelines

CRITICAL WARNING: Completely de-energize the PLC master power and isolate all field connections prior to mounting, dismounting, or pulling the pluggable wiring head from the KS3064 housing. Removing the module or terminal strip under active load can corrupt K-bus communication registers, causing unexpected bus master shutdowns and terminal diagnostic faults.
  1. 1

    Align the KS3064 terminal housing with the 35 mm DIN rail (EN 60715) and push firmly until the locking mechanism clicks audibly.

  2. 2

    Slide the terminal adjacent to the surrounding K-bus modules until the integrated tongue-and-groove side locking tracks slot securely together.

  3. 3

    Insert pre-stripped wire conductors (stripped length: 9 to 10 mm) into the pluggable tension-clamp terminal by depressing the spring actuator latch with a flat-head terminal screwdriver.

  4. 4

    Seat the pluggable terminal connector block firmly into the KS3064 front housing interface until it is fully retained.

What is the primary difference between the Beckhoff KS3064 and KL3064 modules?

The KS3064 features a removable, pluggable terminal connector block on the front housing. The KL3064 uses fixed tension-clamps. Internally, they share the identical electrical, software, and K-bus architecture.

Do the input channels on the KS3064 have independent grounds?

No. The KS3064 utilizes a single-ended architecture, meaning all four analog input channels share a common internal signal ground (0 V reference) inside the bus terminal.

How is the module powered, and does it require external power contacts?

The KS3064 draws its operating current of typically 85 mA directly from the K-bus via the Bus Coupler. It does not possess power contacts and does not require external field-side terminal supply voltage to operate.

Which software platforms support the configuration of this Bus Terminal?

The KS3064 is fully supported across all TwinCAT programming environments (TwinCAT 2 and TwinCAT 3) via the standard Beckhoff System Manager, requiring no specialized hardware description files.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...