Product Overview

The CX5120-N031 (CX5120N031) is a high-performance, fanless Embedded PC designed for DIN rail mounting, powered by an efficient Intel Atom® multi-core processor. This specific configuration is equipped with a factory-integrated RS485 interface via a 9-pin D-sub socket, specifically configured for use as an end point. In industrial B2B sectors such as building automation, renewable energy monitoring, and long-distance serial networking, the CX5120-N031 serves as a robust intelligent controller. It excels in bridging high-speed EtherCAT I/O with legacy serial bus systems, providing the computational overhead required for TwinCAT 3 PLC and Motion Control tasks while maintaining a rugged, maintenance-free hardware profile.

Technical Configuration (Deep Dive)

The CX5120-N031 is technically optimized for RS485 bus integrity. Unlike the -0002 variant, this "N031" model is pre-configured as an end point with termination on. This means the internal 120-ohm termination resistor is active, and the module is set to without echo (half-duplex). This configuration is critical for preventing signal reflections in serial RS485 networks, ensuring high-speed data reliability over long cable runs without the need for external resistors.

The unit leverages the advanced Intel Atom® architecture to deliver a superior performance-to-watt ratio. It supports automatic recognition of both E-bus (EtherCAT) and K-bus (Bus Terminals), allowing it to function as a universal head-station for any Beckhoff I/O segment. The fanless design ensures longevity in dusty or vibration-prone environments where active cooling would fail.

Technical Specifications

Attribute Specification Details
Model CX5120-N031
Brand BECKHOFF
Processor Intel Atom® (High-efficiency Multi-core)
Interface Type 1 x RS485
Connection Port 9-pin D-sub socket
RS485 Config End point, without echo, Termination ON
Expansion Bus Automatic E-bus / K-bus recognition
Cooling Fanless (Passive Convection)
Installation 35 mm DIN rail (EN 60715)
Operating Temp -25 to +60 Celsius
Weight Approx. 590 g
Protection Rating IP20
Power Supply 24 VDC (-15 % / +20 %)

Technical FAQs

What does "Termination ON" mean for my network design?

The CX5120-N031 has an internal 120-ohm resistor engaged across the RS485 data lines. This module must be placed at the physical beginning or the physical end of your RS485 daisy-chain to ensure impedance matching and prevent signal distortion.

Can I use this for Modbus RTU communication?

Absolutely. The RS485 interface is fully compatible with the Modbus RTU protocol. In TwinCAT, you can simply map the serial port to the Modbus RTU master or slave library to communicate with drives, meters, or third-party sensors.

Does this model support TwinCAT 3 Platform Level 40?

Yes. The CX5120 series typically operates at the Performance (40) platform level, providing ample power for multi-tasking PLC environments and complex communication handling.


Engineering & Installation Guide

  • Network Topology: Because this unit is configured with internal termination, avoid placing it in the middle of an RS485 bus. Doing so would load the bus incorrectly and likely cause communication errors. Always use shielded, twisted-pair cable for the D-sub connection.

  • Thermal Clearances: For fanless operation up to 60 Celsius, the unit must be mounted horizontally. Ensure a minimum of 30 mm of free space above and below the cooling fins to allow for natural heat dissipation.

  • Bus Integration: The CX5120 detects the connected I/O bus type during the boot phase. When switching from E-bus to K-bus terminals, ensure a complete power cycle of the system to allow the automatic bus recognition logic to reset.

Engineering Advantages

The CX5120-N031 represents a professional-grade solution for "Legacy-to-Industry 4.0" integration. By integrating a hardware-terminated RS485 port directly into a powerful Intel Atom® PC, it reduces the need for external gateways and specialized wiring. Its durability is proven by its compliance with EN 60068-2-6/27 for vibration and shock resistance, ensuring it remains operational in the most demanding industrial settings. The combination of high-speed local I/O expansion and ready-to-use serial networking makes it one of the most flexible Embedded PCs in the Beckhoff portfolio.

 

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Bạc
Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...