1 trong số 1

EL2042 2-Channel Digital Output Terminal 24 VDC 4A High Current

EL2042 2-Channel Digital Output Terminal 24 VDC 4A High Current

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL2042

  • Country of origin:Đức

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The EL2042 (EL2042) is a high-capacity 2-channel digital output terminal engineered for the EtherCAT I/O system, specifically designed to drive heavy industrial loads. While standard output terminals often peak at 0.5 A, the EL2042 delivers a robust 4.0 A per channel, or up to 8.0 A through parallel connection. In demanding applications such as hydraulic valve control, large DC motor starters, and high-intensity heating elements, this terminal provides the necessary power without the need for intermediate relays. Featuring advanced diagnostics for short-circuit and open-circuit detection, the EL2042 enhances system reliability by providing real-time feedback to the controller, significantly reducing troubleshooting time in 24/7 manufacturing operations.

Technical Configuration

The EL2042 utilizes a 3-wire connection technology, allowing for the direct connection of loads without additional terminal blocks for ground or power distribution. The output stages are fully short-circuit proof and designed to handle ohmic, inductive, and lamp loads with ease. A standout technical feature is its high breaking energy of < 1.7 J per channel, which allows it to safely dissipate the stored energy of large inductive coils during switch-off. The module operates with a fast response time (TON: 40 µs) and provides 500 V electrical isolation between the E-bus logic and the field potential. The high-density design fits within a standard 12 mm housing, maintaining the compact footprint of the EtherCAT terminal block while delivering significant power output.

Technical Specifications

Feature Specification
Model EL2042
Brand BECKHOFF
Number of Outputs 2
Max. Output Current 4.0 A per channel (8.0 A parallel)
Connection Type 3-wire
Nominal Voltage 24 V DC (-15 percent / +20 percent)
Breaking Energy < 1.7 J per channel
Diagnostics Short circuit and Open circuit
E-bus Consumption Typ. 120 mA
Switching Times Typ. TON: 40 µs, TOFF: 200 µs
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Operating Temp -25 to 60 deg C

Technical FAQs

How do I configure the terminal for 8.0 A parallel operation?

To achieve an 8.0 A output, both output channels must be wired in parallel to the same load and switched simultaneously within the TwinCAT PLC program. Because the EL2042 is short-circuit proof and features synchronized switching capability, it can safely share the load current across both internal semiconductor switches.

What is the benefit of the integrated "Open Circuit" diagnostics?

The open-circuit diagnostic feature allows the PLC to detect if a wire has been broken or if a load (like a solenoid coil) has failed, even when the output is in the "OFF" state. This allows for immediate alarming before the machine attempts a cycle, preventing potential mechanical damage or wasted production cycles.

Does this terminal require a separate power feed?

The EL2042 draws its output current from the power contacts of the EtherCAT terminal block. Given its high current capacity (up to 8.0 A), it is critical to ensure that the preceding power feed terminal (like an EL9100 or EK1100) and the total current load on the power contact rail do not exceed the 10 A maximum limit.


Engineering & Installation Guide

  • Thermal Management: When operating both channels at the maximum 4.0 A capacity, the terminal generates internal heat. Ensure the control cabinet has adequate ventilation and that the operating temperature does not exceed 60 deg C. If multiple EL2042 units are used side-by-side at full load, consider using a fan or providing spacing to prevent thermal tripping.

  • Wiring Requirements: Due to the 4.0 A current per channel, ensure the wire gauge used is sufficient to prevent voltage drops. The terminal supports up to 2.5 mm squared (AWG 14) for solid or stranded wire. Using ferrules with a cross-section of 1.5 mm squared is recommended for flexible conductors to ensure a vibration-proof connection.

  • Inductive Load Protection: While the EL2042 has a high breaking energy rating of 1.7 J, very large inductive loads (such as large brake magnets) may still produce significant back-EMF. In such cases, installing an external flyback diode directly at the load can help protect the terminal's internal components and reduce electromagnetic interference (EMI).

 

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám
Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...