1 trong số 3

Emerson PR6426/010-000 CON021/916-160 Eddy Current Sensor System

Emerson PR6426/010-000 CON021/916-160 Eddy Current Sensor System

Only 3 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: PR6426/010-000 CON021/916-160

  • Country of origin:Hoa Kỳ

  • Product Type: Eddy Current Displacement Sensors

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 920g

  • Dimensions: 23cm x 20cm x 5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The Emerson PR6426/010-000 non-contact sensor combined with the CON021/916-160 signal converter forms an industrial eddy current measurement system optimized for critical turbomachinery applications, including steam, gas, and hydro turbines, compressors, pumps, and fans. The PR6426 eddy current sensor detects radial and axial shaft displacement, position, eccentricity, and motion under harsh operating conditions. The matched CON021/916-160 converter accurately processes these proximity metrics into reliable electrical signals required by machinery protection and TSI monitoring platforms.

Features

  • Non-contact eddy current measurement technique for precise tracking of shaft position and dynamics
  • Robust engineering built to withstand demanding and tough industrial conditions
  • Sensor tip assembly capable of enduring high pressure up to 6,500 hpa
  • Stable signal translation over an extended displacement range up to 16.0mm
  • Unarmored cable layout equipped with a premium self-locking plug connector interface

Applications

  • Radial and axial shaft dynamic displacement monitoring
  • Turbomachinery position, motion, and eccentricity registration
  • Comprehensive mechanical protection loops for high-speed gas/steam turbines and heavy compressors

Ordering Information

Model Number Configuration / Description Measuring Range Linearity Error
PR6426/010-000 32mm Eddy Current Sensor, No Sleeve Thread, Unarmored Cable, Mounting Plate, Without Adaptor Plug +/-4.0 mm (Standard Range) / 16.0mm Extended <= 1.5% max (Sensor)
CON021/916-160 Sensor Signal Converter for PR6426 16.0mm (Extended Range) <= 2.0%

Technical Specifications

CON021/916-160 Signal Converter Specifications

Parameter Specification
Manufacturer Emerson
Frequency Range (-3 dB) 0 to 20000 Hz
Rise Time <15 us
Operating Temperature Range -30 to 100 degC (-22 to 212 Fahrenheit)
Shock and Vibration 5g @ 60 Hz @ 25 degC (77 Fahrenheit)
Protection Class IP20
Supply Voltage Range (-24V config) -23V to -32V (Output Range: -4V to -20V)
Supply Voltage Range (-2V config) -21V to -32V (Output Range: -2V to -18V)
Housing Material LMgSi 0.5 F22
Weight ~120 grams (4.24 oz)
Mounting Hardware 4 Screws M5x20

PR6426 Eddy Current Sensor Specifications

Parameter Specification
Tip Diameter 32mm
Sensitivity 2 V/mm (50.8 mV/mil) <= +/-1.5% max
Air Gap (Center) Approx. 5.5 mm (0.22") Nominal
Long Term Drift <0.3%
Target/Surface Material Ferromagnetic Steel (42 Cr Mo 4 Standard)
Maximum Surface Speed 2,500 m/s (98,425 ips)
Minimum Shaft Diameter 200 mm (7.87")
Operating Temperature Range -35 to 175 degC (-31 to 347 Fahrenheit)
Temperature Excursions (<4 Hours) 200 degC (392 Fahrenheit)
Maximum Cable Temperature 200 degC (392 Fahrenheit)
Pressure Resistance to Sensor Head 6,500 hpa (94 psi)
Shock and Vibration 5g (49.05 m/s2) @ 60Hz @ 25 degC (77 Fahrenheit)
Sleeve Material Stainless Steel
Cable Material PTFE
Weight (Sensor & 1M Cable, no Armor) ~800 grams (28.22 oz)

Connections/Interfaces

Connector Pin / Terminal Function
Transducer Connection Self-Locking Lemo-Plug
Supply/Output Connection Screw Terminal Type (max. 1.5mm2 wire)

Installation Guidelines

  • Ensure the unarmored sensor cable respects a minimum static bending radius of 25 mm during routing.
  • Keep a clear exclusion zone of at least 80 mm diameter centered around the 32mm sensor head to eliminate peripheral metal interference.
  • Adjust the mechanical probe position to find the nominal center air gap of approximately 5.5 mm before locking down.
  • Use appropriate safety barriers and signal isolation paths when routing transducer loops through explosive or certified hazardous zones.

Compliance and Certifications

  • CE: 2014/30/EU (EN 61326-1), 2014/34/EU, 2011/65/EU, DIN EN 50581
  • ATEX: EN 60079-0, EN 60079-11 (II 2 G Ex ia IIC T4 Gb, -20 degC <= Ta <= 80 degC)
  • IEC-Ex: IEC 60079-0, IEC 60079-11, IEC 60079-26 (Ex ia IIC T4 Gb, -20 degC <= Ta <= 80 degC)
  • CSA: CAN/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04 (Class I Division 1, Groups A, B, C, D, T4; Class I Division 2, Groups A, B, C, D Ex nA II T3..T4)
  • Standards: ANSI/UL Standard 913-2004, ANSI/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson PR6426/010-000 CON021/916-160 Eddy Current Sensor System

What measurement span does this specific extended sensor configuration provide?

When mated with the extended range converter, this 32mm eddy current sensor configuration delivers a total linear measurement span of 16.0mm.

What type of cable construction is used on this exact sensor model?

This specific model features an unarmored PTFE cable configuration terminating in a self-locking Lemo plug connector.

What are the ambient temperature classifications under the CSA standard for this device?

The sensor temperature classification is graded as T6 for ambient temperatures up to 64 degC, T4 up to 114 degC, and T3 up to 160 degC.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...