1 trong số 3

Emerson VS3202 KJ2201X1-BA1 DeltaV SIS Logic Solver Module

Emerson VS3202 KJ2201X1-BA1 DeltaV SIS Logic Solver Module

Only 8 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: VS3202 KJ2201X1-BA1

  • Country of origin:Hoa Kỳ

  • Product Type: Logic Solver Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 8.3cm x 12.5cm x 10.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The Emerson VS3202 KJ2201X1-BA1 is a safety-certified safety instrumented system module engineered as part of the DeltaV SIS platform. This logic solver, also designated as the SLS 1508, provides dedicated safety loop execution independent from standard regulatory control layers while remaining integrated within the configuration and diagnostic environment. The module communicates with intelligent field sensors via the HART protocol to diagnose faults before they manifest as process interruptions. It is built to fulfill safety instrumented functions across modern processing facilities, ensuring continuous process availability and asset protection.

Features

  • Decoupled execution system separating emergency safety logic from regulatory process control
  • Integrated safety bus capabilities managing field level instrumentation directly via HART diagnostics
  • Scalable architecture allowing step-by-step sizing adjustments to fit individual application footprints
  • Hot-swappable hardware design permitting the online addition of redundant safety components

Applications

  • Safety Instrumented Systems (SIS) logic solving loops
  • Emergency Shutdown (ESD) architectures
  • Fire and Gas (F&G) management integration
  • High-integrity burner management and protection systems

Ordering Information

Description Model Number
DeltaV SLS 1508 Redundant Logic Solver – includes Terminal Block VS3202 VS3202 / SLS 1508

Technical Specifications

Power Specifications

Parameter Specification
Local Bus Power 24 VDC at 1 A
Field Power 4 A (maximum)

Environmental Specifications

Parameter Specification
Ambient Temperature -40 degC to +70 degC
Shock 10g 1/2 Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz; 0.7g from 13.2 to 150Hz
Airborne Contaminants ISA-S71.04-1985 Airborne Contaminants Class G3
Relative Humidity 5 to 95% Non-Condensing

Installation Guidelines

  • Ensure field power supplied to this device, either at the field terminal or as bussed field power through the carrier, is completely removed before connecting or disconnecting the module.
  • Do not remove or insert the unit with system power energized unless the area is verified to be non-hazardous.
  • Mount the module within environments complying with ISA-S71.04-1985 Class G3 standards to prevent corrosion from airborne contaminants.
  • Verify all redundant wiring and bus configurations are completed prior to initial software commissioning or online extension steps.

Compliance and Certifications

  • ATEX: II 3G Ex ec IIC Gc (FM16ATEX0056U)
  • UKEX: Ex ec IIC Gc (FM21UKEX0017U)
  • FM Approved: CL. I Div. 2 GP. A,B,C,D; CL. I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U, FM17CA0145U)
  • TÜV NORD: IEC 61508:2000 SIL 3 Capability
  • CE: Certified

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson VS3202 KJ2201X1-BA1 DeltaV SIS Logic Solver Module

Can this safety module be removed or inserted while the system is energized?

The module cannot be removed or inserted with system power energized unless the surrounding environment is explicitly verified to be non-hazardous.

What is the certified ambient operating temperature limit for the device?

The device is certified to operate within an ambient temperature range of -40 degC to +70 degC.

What standard must be met regarding airborne contamination at the installation site?

The installation site should satisfy the requirements for an ISA-S71.04-1985 Airborne Contaminants Class G3 environment.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Vàng
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...