GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

Only 6 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: SR745-W3-P511-G51-HI-R-E

  • Country of origin:Hoa Kỳ

  • Product Type: Transformer Protection System

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 8500g

  • Dimensions: 220 mm x 275 mm x 300 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The GE Multilin 745-W3-P511-G51-HI-R-E is a digital, three-winding transformer protection system engineered for the primary protection, management, and control of power transformers. This high-performance device delivers comprehensive multi-winding differential protection, adaptive harmonic restraint, and extensive overcurrent protection elements within a rugged draw-out construction. It features advanced internal logic and precise high-accuracy metering to eliminate the need for extra external components or auxiliary transducers. The unit is configured with 5 A phase current inputs and 5 A ground current inputs across its winding interfaces to match specific system requirements. Outfitted with high-speed processing, comprehensive data logging, and flexible communication ports, the device interfaces seamlessly with distributed control systems (DCS) and SCADA automation architectures to monitor asset health and maintain system integrity.

Features

  • Comprehensive three-winding transformer differential protection with percentage restraint and adaptive harmonic blocking.
  • Draw-out chassis construction allowing quick unit replacement and drastically reduced system maintenance downtime.
  • Integrated high-accuracy metering functions for current, voltage, power, and frequency parameters without auxiliary equipment.
  • Advanced fault diagnostics incorporating precise sequence-of-events reporting, oscillography, and waveform capture.
  • Multiple user-programmable analog and digital inputs/outputs for extensive control and interlocking logic schemes.
  • High-speed communications supporting industrial protocols for integration into SCADA networks.
  • FlexLogic programming capabilities allowing users to customize control sequences and interlocking logic without extra hardware.
  • Front-panel enhanced user interface with an informative LCD screen and tactile keypad for straightforward configuration and diagnostic readout.

Applications

  • Primary protection and control for three-winding power transformers in utility and industrial substations.
  • Main or backup differential and overcurrent protection for auto-transformers and multi-winding generation transformers.
  • Comprehensive asset monitoring, load profiling, and transformer thermal overload tracking in power networks.
  • Advanced power system automation requiring high-speed network reporting and protective relay interlocking.

Ordering Information

Selection Code Technical Specification Description
745 Base model for Transformer Protection System
W3 Three-Winding Transformer Protection
P511 5 A Phase Current Inputs (Winding 1, Winding 2, Winding 3)
G51 5 A Ground Current Inputs (Winding 1, Winding 2)
HI 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz Power Supply
R Red Breaker Closed LED Indicator
E Enhanced Display, Larger LCD, and Improved Keypad

 

Technical Specifications

Parameter Specification
Manufacturer GE Multilin (GE Vernova)
Transformer Windings (W3) 3 Windings
Phase Current Inputs (P511) 5 A for all three windings
Ground Current Inputs (G51) 5 A for Winding 1 and Winding 2
Power Supply Option (HI) 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz
Breaker Status LED (R) Red breaker closed LED indicator
User Interface (E) Enhanced display, larger LCD, and improved keypad layout

Installation Guidelines

  • Chassis Mounting: Securely mount the draw-out chassis into the instrument panel cutout using standard hardware guidelines designated for the unit frame.
  • Grounding Protocols: Connect a dedicated, low-impedance grounding copper wire directly to the chassis ground terminal to mitigate electrical noise and protect sensitive circuitry.
  • Wiring Requirements: Route current transformer (CT) and voltage transformer (VT) connections isolated from low-voltage signal wiring and communication lines to mitigate EMI/RFI issues.
  • CT Circuit Integrity: Ensure all phase and ground current transformer secondary circuits are fully verified and safely terminated to the correct rear blocks prior to operational power-up.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

What is the function of the W3 designation in the relay model code?

The W3 designation specifies that the device is configured to support comprehensive primary differential and overcurrent protection for a three-winding power transformer.

What input current ratings do the P511 and G51 options provide?

The P511 option provides 5 A phase current inputs for all three transformer windings, while the G51 option provides 5 A ground current inputs for Winding 1 and Winding 2.

What source voltage limits are supported by the HI power supply option?

The HI power supply option operates safely over an input range of 88 to 300 VDC and 70 to 265 VAC at a frequency of 48 to 62 Hz.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...