1 trong số 3

GE Multilin UR-6TH Universal Relay Series Digital I/O Module

GE Multilin UR-6TH Universal Relay Series Digital I/O Module

Only 2 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-6TH

  • Country of origin:Hoa Kỳ

  • Product Type: Digital I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 660g

  • Dimensions: 16.3cm x 4.2cm x 21cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The UR-6TH (UR6TH) functions as a high-density Digital Input/Output Module engineered for the GE Vernova Multilin Universal Relay (UR) platform series. This hardware expansion block integrates directly into standard modular UR chassis frameworks—such as the F60, L90, G60, and B30 protective relays—to execute rapid interlocking logic and telemetry distribution across electrical substations and heavy industrial energy systems. It features an onboard combination of 8 contact inputs and 4 Form-A outputs specifically optimized to drive high-speed control commands.

The Form-A digital outputs operate without internal contact monitoring, utilizing advanced mechanical design to achieve a response duration of less than 4 ms. This ultra-fast switching profile makes the hardware highly appropriate for deployment inside master circuit breaker trip circuits where immediate arc interruption and protection sequence execution are mandatory. Operating within the host relay's native firmware architecture, the localized input and output paths are managed dynamically over internal backplane links via EnerVista UR Setup Software to automate sequence mapping and minimize physical auxiliary control panel wiring footprints.

Features

  • High-Speed Form-A Outputs: Equipped with 4 non-monitored Form-A contacts achieving an ultra-fast response speed of under 4 ms for direct breaker tripping applications.
  • Dense Contact Acquisition: Features 8 independent contact inputs to capture discrete status changes from auxiliary power equipment.
  • FlexLogic Programming Integration: Fully maps all 8 inputs and 4 outputs into the internal FlexLogic editor for tailored automation, automated overcurrent tripping, and external blocking schemes.
  • Hardwired Reduction Layout: Significantly decreases complex secondary hardwiring infrastructures inside traditional substation panel bays through localized digital point concentration.
  • Flexible Voltage Compatibility: Supports standard industrial DC control voltages spanning from 24V DC up to 250V DC depending on the definitive system configuration.

Applications

  • High-speed circuit breaker direct tripping (Trip) circuits.
  • Automated substation equipment interlocking and signaling networks.
  • Digital input/output point expansions for Multilin UR Series relays (F60, L90, G60, B30).
  • Distributed industrial power management systems requiring custom logic mapping.

Technical Specifications

Parameter Specification & Technical Details
Manufacturer GE Vernova (Grid Solutions / Multilin) 
Model UR-6TH 
Module Type Digital Input/Output Module (Digital I/O Module) 
Product Family Multilin Universal Relay (UR) Series 
Input Channels 8 Contact Inputs 
Output Channels 4 Form-A Outputs (No Monitoring) 
Output Response Speed < 4 ms (Ultra-high-speed response) 
Rated Control Voltage 24V DC to 250V DC (Dependent on ordering code & configuration) 
Configuration Tool EnerVista UR Setup Software 
Net Weight Approx. 2 lbs 9 oz (1.16 kg) 
Dimensions (H x W x L) Approx. 1.5 in x 6 in x 7 in (3.8 x 15.2 x 17.8 cm) 

Installation Guidelines

Hardware Compatibility Verification

When replacing or upgrading modular cards within an active relay system, ensure the new I/O module matching specifications align completely with the host relay's CPU generation and chassis type. Universal Relay I/O cards vary severely in feature layouts, such as the inclusion or omission of contact monitoring. Always compare the full alphanumeric ordering code printed on the primary relay nameplate and verify the targeted physical card slot (typically slots G, H, M, N, P, U, or W) before seating the hardware.

Pre-Installation Power Isolation

  • Completely disconnect the main secondary AC/DC auxiliary power supply feeding the Universal Relay host unit.
  • Isolate or mechanically lock out all external current, voltage, and circuit breaker trip loops terminating at the external field terminal blocks to avoid accidental field breaker deployment during the swap procedure.
  • Securely attach an electrostatic discharge (ESD) wrist strap and connect it to a verified physical earth ground to protect internal microprocessors from static electricity degradation.

Extracting the Defunct Module

  1. Connect a PC to the relay and execute a full parameter backup via the EnerVista UR software, saving the current configuration as a .urs file.
  2. Loosen the physical faceplate retaining fasteners situated at the top and bottom exterior corners of the target I/O slot frame using an appropriate screwdriver.
  3. Grip the integrated black extraction handles firmly and pull the module outward along a straight, uniform path to disengage the board from the rear backplane bus assembly.

Inserting the New UR-6TH Module

  1. Position the vertical side edges of the new UR-6TH circuit card inside the molded plastic guide tracks of the empty chassis slot.
  2. Slide the module into the empty slot cavity smoothly until the outer front faceplate fits flush against the adjacent structural modules.
  3. Apply firm, centered horizontal pressure on the faceplate borders to make sure the multi-pin rear connector seats completely into the backplane plug.
  4. Tighten both the upper and lower panel retention screws to provide mechanical stability and complete the mandatory chassis grounding loop.

Post-Installation Commissioning

  1. Reapply the system auxiliary power distribution to the primary power module of the relay chassis.
  2. Monitor the automated self-test routine via the liquid crystal faceplate screen; confirm that no HARDWARE MISMATCH alerts or critical slot fault flags become active.
  3. Connect via the EnerVista software suite, navigate to Status -> Hardware Configuration, and verify that the system correctly enumerates the new UR-6TH hardware block before restoring live operation to external I/O trip loops.

FAQ

What specific type of switching contacts are provided on the output channels? 

The module contains 4 Form-A outputs which are Single Pole-Single Throw Normally Open (SPST-NO) contacts. These outputs are engineered without internal current or voltage monitoring components to maximize switching speed and minimize response delays under 4 ms, rendering them excellent for raw breaker trip routing.

Can this module be positioned in any slot within the Universal Relay frame? 

No, this module must be positioned specifically in standard designated digital I/O slot spaces. These correspond to slots G, H, M, N, P, U, or W within the standard Universal Relay chassis architecture, depending on how your specific primary configuration code is assigned.

What occurs if the hardware generation of the module does not match the host relay frame?

 If a hardware generation conflict happens between the newly inserted card and the legacy CPU or backplane firmware, the front faceplate of the Universal Relay will trip a critical fault indicator and throw a HARDWARE MISMATCH state, locking out operational software execution until the modules are unified.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...