Honeywell C200 TK-ODK161 AC Output Module

Honeywell C200 TK-ODK161 AC Output Module

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TK-ODK161

  • Country of origin:Hoa Kỳ

  • Product Type: AC output module

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The TK-ODK161 is a high-density, isolated AC Output Module designed for integration into Honeywell process automation systems. This module features 16 individually isolated output channels engineered to switch alternating current loads across a wide voltage spectrum ranging from 74 to 265 VAC at line frequencies of 47 to 63 Hz. Each output is constructed with dedicated galvanic isolation barriers to prevent cross-channel interference and shield supervisory backplane electronics from field-side electrical transients. Designed for reliable signal delivery to final control elements such as solenoids, motor starters, and indicators, the module incorporates zero-crossing synchronization to suppress electromagnetic interference and thermal stress during load transitions.

Features

  • 16 individually isolated output circuits providing channel-to-channel and user-to-system galvanic separation.
  • Low on-state voltage drop and optimized power dissipation parameters for dense cabinet enclosures.
  • High peak surge current capability to accommodate inductive and capacitive inrush loads.
  • Integrated zero-crossing inhibition mechanisms to prolong field device operational life.
  • Direct compatibility with high-density 36-position connection terminal blocks.

Applications

  • Control of industrial solenoid valves and actuators.
  • Interfacing with fixed-speed AC motor starters and contactors.
  • Execution of pilot light arrays and visual signaling systems.
  • Segregated load switching in chemical, petrochemical, and power generation environments.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model TK-ODK161
Product Type AC Output Module
Number of Outputs 16 (individually isolated)
Output Voltage Range 74-265 VAC, 47-63 Hz
Output Current Rating (Per Point) 2.0 A max @ 30 Celsius & 2.0 A max @ 60 Celsius
Output Current Rating (Per Module) 5.0 A max @ 30 Celsius & 4.0 A max @ 60 Celsius
Surge Current 20 A for 43 ms each, repeatable every 2 sec @ 60 Celsius
On-State Current (Minimum) 10 mA per output
On-State Voltage Drop (Maximum) 1.5 Vrms @ 2.0 A, 6.0 Vrms @ I < 50 mA
Maximum Inhibit Voltage 60 V peak (zero crossing)
Off-State Leakage Current (Maximum) 3 mA per point
Output Signal Delay (Off to On / On to Off) 9.3 ms @ 60 Hz; 11 ms @ 50 Hz
Power Dissipation 9.6 W max
Backplane Current Draw (24 VDC) 0.002 A
Backplane Current Draw (5 VDC) 0.300 A
Isolation Voltage (Channel to Channel) 100% tested at 2546 VDC for 1s
Isolation Voltage (User to System) 100% tested at 2546 VDC for 1s
Connection Terminal Blocks TC-TBCH (36-position terminal block)
Weight 1 kg
Shipping Weight 2 kg

Connections/Interfaces

Connector Pin Function
TC-TBCH Terminal Slot 36-position terminal block interface mapping for 16 isolated channels

Installation Guidelines

Grounding and Shielding

Ensure that the chassis rack and mounting backplane are securely bonded to the plant instrumentation grounding network. Field wiring shields, if deployed for noise mitigation, must be terminated at designated shield grounding bars outside the module assembly to prevent stray currents from entering the control logic plane.

Handling and ESD Protection

Electrostatic discharge can degrade or destroy internal solid-state components. Prior to inserting, removing, or wiring the module, personnel must wear a properly grounded static-dissipative wrist strap. Store and transport the unit exclusively in approved anti-static protective packaging.

Thermal Management and Airflow

Review thermal derating parameters when planning module layouts. Note that the total module current limits scale from 5.0 A at 30 Celsius down to 4.0 A at 60 Celsius. Maintain proper clearance margins between high-power equipment and the chassis to promote unhindered natural convection or forced-air circulation.

Wiring and Terminal Block Assignment

All field connections must be wired through the compatible TC-TBCH 36-position terminal block. Verify that the load requirements meet the minimum on-state threshold of 10 mA per output to guarantee proper switching operations and prevent leakage current false-activation states.

FAQ

What is the electrical isolation rating between channels for this module?

Every channel is fully isolated from adjacent circuits, withstanding testing procedures at 2546 VDC for a duration of 1 second.

What happens if the ambient operational temperature increases from 30 to 60 Celsius?

While individual points remain rated up to 2.0 A, the collective maximum module current capacity decreases from 5.0 A to 4.0 A.

Can this unit switch low-power instrumentation signals below 10 mA?

No, a minimum on-state current threshold of 10 mA per output channel is necessary for the solid-state switching circuitry to operate correctly.

What specific terminal block is required to interface with field wiring?

This module requires the TC-TBCH 36-position terminal block for managing field-side connections.

Does this device feature zero-crossing switching attributes?

Yes, it limits switching based on a maximum zero-crossing inhibit voltage threshold of 60 V peak to minimize inductive surges.

What is the typical output signal delay when operating on a standard 50 Hz line?

The propagation and signal processing delay for both turning on and turning off is approximately 11 ms at 50 Hz.

How much power does the module draw from the 24 VDC backplane supply?

The nominal continuous current consumption from the 24 VDC rail is extremely low, specified at 0.002 A.

What is the maximum transient surge current individual channels can tolerate?

Each output point can endure an inrush surge current of up to 20 A lasting for 43 ms, repeatable every 2 seconds at 60 Celsius.

What level of leakage current should be expected when an output is turned off?

The off-state leakage current can reach a maximum value of 3 mA per individual output point.

What is the net weight of the module excluding shipping materials?

The unboxed module weight is exactly 1 kg.

Key Features:

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...