1 trong số 1

Mitsubishi Electric FR-E840-0380-4-60 FR-E800 Series Variable Frequency Drive

Mitsubishi Electric FR-E840-0380-4-60 FR-E800 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-E840-0380-4-60

  • Country of origin:Hoa Kỳ

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 11000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Integrating the Mitsubishi Electric FR-E840-0380-4-60 within an industrial motor control network delivers precise speed regulation and reliable torque management for demanding three-phase systems. This 400V class variable frequency drive from the FR-E800 Series features a Normal Duty (ND) rated current of 38A, specifically engineered with safety-stop capabilities and a robust circuit board coating to survive harsh industrial environments.

Features

  • Voltage Class: High-performance 400 V class design optimized for global standard three-phase power supplies.
  • Conformal Coating: Circuit boards feature a protective coating (-60 specification) to defend against dust, humidity, and corrosive gases.
  • Flexible Control Logic: Configured for source logic control input and a source-logic fixed safety stop signal.
  • Monitoring and Output: Built-in AM terminal provides precise voltage-based analog monitoring.
  • Advanced Thermal Design: Designed without plated conductors, prioritizing material durability and consistent heat dissipation.

Applications

  • Conveyor and material handling systems requiring strict torque control.
  • Industrial fans, exhaust blowers, and centrifugal pumping systems.
  • Packaging, wrapping, and labeling machinery.
  • Textile, paper processing, and manufacturing machinery.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number FR-E840-0380-4-60
Series FR-E800
Input Voltage Class 400 V Class (Three-Phase Input)
Normal Duty (ND) Rated Current 38.0 A
Rated Frequency 50 Hz (Initial setting)
Input Signal Logic Source logic (Initial status)
Safety Stop Signal Source logic (Fixed)
Monitoring Protocol Spec Voltage (Terminal AM)
Circuit Board Protection With coating (-60 spec)
Plated Conductor Without plated conductors
Net Weight 11.0 kg
Shipping Weight (Calculated) 14.0 kg

Connections and Interfaces

Terminal / Port Function / Circuit Assignment
AM Analog voltage output monitoring terminal.
S1, S2, SC Safety stop input circuit terminals (Source logic configuration).
R/L1, S/L2, T/L3 Three-phase AC power input terminals.
U, V, W Three-phase AC output connections to the motor.

Alternative Models & Compatibility

The FR-E840-0380-4-60 belongs to the modern FR-E800 generation, succeeding many legacy FR-E700 series models. When migrating, note that the physical dimensions and terminal positions may vary. Suffixes like "-60" are critical for installations in aggressive, high-humidity, or chemical-heavy production plants; using standard non-coated variants in these settings will drastically reduce the Mean Time Between Failures (MTBF).

Application Pitfalls & Engineering Notes

When designing sealed control enclosures, do not rely purely on the integrated cooling fan. A 38A drive dissipates significant thermal energy under high-load cycles. Ensure local cabinet venting is calculated to prevent internal temperatures from exceeding 50 degC. Ensure that the source logic safety inputs are configured only with safe, isolated external power supplies to prevent common-mode noise issues.

Commissioning & Wiring Tips

Always run motor power cables and control/signal lines in separate, isolated metal conduits. Keep the distance between the drive output terminals (U, V, W) and the motor as short as possible; if motor cables exceed 30 meters, installing an output AC reactor is highly recommended to suppress parasitic capacitive currents and protect the motor insulation from high dV/dt voltage spikes.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages remain present in the internal DC bus capacitors even after the mains power supply is isolated. Disconnect all primary power and wait at least 10 minutes. Confirm that the charge lamp is fully extinguished and verify the voltage across the main circuit terminals is near 0 V before attempting to wire or inspect the unit.
1

Mount the inverter vertically on a flat, non-flammable surface. Ensure clear air-flow zones of at least 50 mm above and below the drive framework.

2

Connect the physical earth ground wire directly to the drive's dedicated grounding terminal before wiring power input paths.

3

Terminate the three-phase AC power supply wires to R/L1, S/L2, and T/L3. Connect the output lines U, V, and W to the motor terminals.

4

Double-check safety stop wiring jumpers and logic selection settings before energizing the device for initial test rotation.

What is the key difference indicated by the -60 suffix in this model?

The -60 suffix specifies that the internal circuit boards are treated with a specialized protective conformal coating. This provides resistance against moisture, industrial dust, and chemical residues, and indicates that the unit is built without plated conductors.

Can this variable frequency drive be configured for sink logic control?

No, this specific model (FR-E840-0380-4-60) is factory-configured for source logic control, and the integrated safety stop signal logic is fixed to source logic.

How long must I wait after powering down before opening the wiring terminal covers?

You must wait at least 10 minutes to allow the high-voltage DC bus capacitors inside the drive to discharge fully. Verify the internal charge LED is fully off before proceeding.

What function does the terminal AM provide on this VFD?

Terminal AM is an analog voltage output monitoring terminal, allowing real-time monitoring of key drive variables such as output frequency, motor current, or voltage using external meters.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...