  • Manufacturer: Mitsubishi Electric

  • Product No.: FX2N-48MR-DS

  • Country of origin:Hoa Kỳ

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 190 x 110 x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Assembling reliable industrial control architectures requires robust processing cores, and the Mitsubishi Electric FX2N-48MR-DS PLC Base Unit delivers exactly that with its high-density input/output configuration and compact form factor. This controller operates on a 24 VDC power supply, making it an ideal choice for mobile, marine, or battery-backed industrial control systems. It integrates 24 digital inputs and 24 relay outputs within a single chassis, facilitating comprehensive local control without requiring immediate extension modules. Built on the proven MELSEC FX2N architecture, this base unit supports high-speed processing, comprehensive instruction sets, and expandable memory structures to handle mid-range manufacturing and process automation tasks with absolute reliability.

Features

  • 24 VDC Power Input: Tailored for standard industrial DC control loops, eliminating the need for AC mains step-down transformers at the controller level.
  • Flexible Input Configuration: 24 digital inputs designed to accept both sink (NPN) and source (PNP) sensor configurations via adjustable terminal wiring.
  • Robust Relay Outputs: 24 electromagnetically isolated relay output channels capable of driving AC or DC actuator loads up to 2A per point.
  • High-Speed Processing: Features integrated high-speed counters and interrupt inputs to accurately track fast-moving industrial pulses.
  • Modular Expandability: Connects seamlessly with FX2N and FX3U expansion blocks, special function modules, and network interfaces for scaling I/O counts.

Applications

  • Automated packaging and cartoning equipment operating on 24V bus architectures.
  • Conveyor tracking, sorting systems, and specialized material handling machinery.
  • Pumping stations, remote telemetry units (RTUs), and localized water treatment plant controls.
  • Marine control systems and auxiliary engine monitoring units demanding direct DC power compliance.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number FX2N-48MR-DS
Series MELSEC FX2N
Supply Voltage 24 VDC (+20% / -15%)
Power Consumption 30 W
Total Integrated I/O 48 points
Digital Inputs 24 points (24 VDC, Sink/Source selectable)
Digital Outputs 24 points (Relay, 2A/point, 8A/common max)
Output Switching Voltage Max. 250 VAC, Max. 30 VDC
Response Time Approx. 10 ms (relay contact mechanical delay)
Program Capacity 8,000 steps (expandable to 16,000 steps with RAM/EEPROM cassettes)
Programming Interface RS-422 (8-pin Mini-DIN)
Ambient Operating Temperature 0 to 55 degC
Country of Origin Japan
Shipping Weight (Calculated) 0.85 kg
Package Dimensions (Calculated) 190 x 110 x 100 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The FX2N series is a legacy workhorse. For modern retrofit configurations where direct replacement stock is limited, the FX3G or FX5U series are suitable functional upgrades. However, note that physical footprint differences and instruction-set updates require code conversion inside GX Works2 or GX Works3. For direct drop-in replacement without modifying the mounting layout, preserving an exact FX2N-48MR-DS unit is critical to avoiding wiring alterations and ensuring compatibility with existing memory cassettes.

Application Pitfalls & Engineering Notes

When switching inductive loads (such as solenoid valves or contactor coils) with the integrated relay outputs, back-EMF spikes can cause contact erosion and premature failure. Always install external RC snubbers across AC loads and flyback diodes across DC loads to protect the internal relays. Additionally, ensure the cabinet's 24 VDC power supply capacity is sized to account for both the 30W PLC draw and the inrush current of all connected field sensors.

Commissioning & Wiring Tips

To configure the digital inputs, locate the "S/S" terminal. Wiring 24V to "S/S" configures the inputs as Sink (NPN type), while wiring 0V to "S/S" configures them as Source (PNP type). To minimize electromagnetic interference on high-speed inputs (X0 through X5), use shielded twisted-pair cables for signal paths and ground the shield only at the PLC chassis grounding terminal.

Installation Guidelines

CRITICAL WARNING

Disconnect all primary power sources before performing any mounting, wiring, or maintenance procedures on the PLC. Verify complete physical de-energization and confirm no residual capacitive charges remain. Failure to isolate power can result in electrical shock, equipment destruction, or erratic machine startup.

1
Mount the controller horizontally onto a standard 35mm DIN rail or directly to the enclosure backplane using the integrated mounting screw holes. Ensure a minimum 50mm clearance on all sides to allow proper convective cooling.
2
Connect the 24 VDC supply power to the dedicated L+ and M terminals on the power supply terminal block. Verify polarity before energizing to prevent input protection fuse failures.
3
Ensure the PLC grounding terminal (Class D grounding, 100 ohms or less resistance) is bonded directly to the main system earth ground point using a heavy-gauge copper conductor.
4
Wire input and output signal lines through the integrated terminal blocks. Keep high-voltage AC lines completely segregated from low-voltage DC signals and communication lines to prevent signal coupling.

Can the inputs on the FX2N-48MR-DS be configured for PNP sourcing field devices?

Yes. By connecting the S/S terminal to the 0V terminal of the power supply, the input circuits are configured to accept PNP (source) input signals.

What is the maximum switching frequency of the relay outputs?

The mechanical relay outputs are designed for low-frequency switching, typically limited to 10 Hz under resistive load, and should not be used for high-speed PWM tasks.

What happens if the internal battery of the controller fails?

If the battery fails, the program stored in the internal volatile RAM can be lost upon power-down. To prevent this, program backups should be written to an optional EEPROM cassette.

Can I expand this base unit with FX3U extension modules?

Yes, standard FX2N expansion units can be used. Many FX3U extension blocks are also backward-compatible, but you must check specific module-level configuration manuals to verify bus loading limitations.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...