1 trong số 1

Mitsubishi Electric L60TCTT4BW-CM MELSEC-L Series Temperature Control Module

Mitsubishi Electric L60TCTT4BW-CM MELSEC-L Series Temperature Control Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: L60TCTT4BW-CM

  • Country of origin:Hoa Kỳ

  • Product Type: PLC Temperature Control Modules

  • Payment: T/T, Western Union

  • Weight: 330g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed for precise, high-density thermal loop regulation, the Mitsubishi Electric L60TCTT4BW-CM provides advanced multi-channel temperature control directly integrated into the MELSEC-L Series PLC platform. This module features four independent thermocouple input channels combined with integrated heater burnout detection, allowing for real-time diagnostics and closed-loop PID control without relying on external transmitter hardware or heavy CPU overhead.

Features

  • Four thermocouple input channels supporting multiple sensor types for high flexibility.
  • Integrated heater disconnection detection using external current transformers (CT) to prevent process failures.
  • Internal PID control loop execution to offload thermal processing from the main PLC CPU.
  • Compact, rack-free modular structure designed for space-restricted control cabinets.
  • Direct parameterization and calibration via standard GX Works2 and GX Works3 software environments.

Applications

  • Plastic extrusion lines and injection molding thermal zones.
  • Industrial packaging machinery and heat-sealing bars.
  • Heat treatment furnaces, drying ovens, and industrial kilns.
  • Chamber temperature regulation in semiconductor manufacturing processes.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Code L60TCTT4BW-CM
Module Type Temperature Control Module (Thermocouple Type)
Number of Input Channels 4 Channels
Compatible Sensor Types Thermocouples: K, J, T, B, R, S, E, N, PLII, W5Re/W26Re
Heater Burnout Detection Supported (via external current transformer inputs)
Sampling Cycle 50 ms / channel
Internal Current Consumption (5V DC) 0.33 A
Weight 0.33 kg
Shipping Weight (Calculated) 2.00 kg
Country of Origin Japan

Connections and Interfaces

Terminal Group Functional Assignment
CH1 to CH4 (+ / -) Thermocouple sensor positive and negative differential inputs
CT1 to CT4 Current Transformer inputs for heater disconnection/burnout monitoring
CJC Cold Junction Compensation sensor connection point

Alternative Models & Compatibility

The L60TCTT4BW-CM serves as a direct drop-in replacement for standard L60TCTT4 series modules. The "-CM" suffix denotes localized documentation packaging but retains absolute hardware, electrical, and register-map parity. It mounts seamlessly to all MELSEC-L CPUs, including the L02CPU, L26CPU-BT, and standard fieldbus interface head modules.

Application Pitfalls & Engineering Notes

When deploying the heater disconnection feature, use only compatible current transformers (CTs) with precise turn ratios as specified in the MELSEC-L hardware manual. Unused thermocouple input channels must be explicitly disabled in the system parameter configurations to prevent the module from throwing sensor open-circuit faults and generating invalid diagnostic data.

Commissioning & Wiring Tips

To guarantee measurement integrity, always route thermocouple compensation cables through dedicated, low-voltage wire ways separate from 480V AC motor cables or VFD outputs. Ensure the shield of the compensation cable is grounded at a single, clean grounding terminal block near the PLC enclosure entry to prevent ground loops from corrupting the high-resolution analog-to-digital converters.

Installation Guidelines

CRITICAL WARNING: Disconnect all power sources feeding the PLC rack, sensor loops, and heater supply lines prior to starting the installation or physical wiring. Failure to isolate power can lead to critical component degradation, short circuits, or electrical shock.
1

Snap the module onto the standard 35mm DIN rail and engage the integrated side-locking joint to interface with the neighboring MELSEC-L module.

2

Connect the thermocouple sensor wires to the terminal block, paying strict attention to correct positive (+) and negative (-) polarity mapping.

3

Terminate the current transformer (CT) cables to the burnout detection pins if utilizing active heater health monitoring.

4

Power up the controller rack and transfer the hardware configuration, including sensor-scaling tables, using GX Works software.

What sensor types are supported by the L60TCTT4BW-CM?

The module natively supports standard industrial thermocouples including K, J, T, B, R, S, E, N, PLII, and W5Re/W26Re configurations.

How does the heater burnout detection work?

It utilizes external current transformers (CTs) wired to dedicated CT inputs on the module, allowing real-time monitoring of current flow while control outputs are active.

Does the L60TCTT4BW-CM require a separate power supply?

No, it draws its primary operating power (0.33 A) directly from the 5V DC internal bus of the MELSEC-L system.

Can I use this module without connecting CT sensors?

Yes. If heater disconnection monitoring is not required, you can leave the CT inputs unwired and disable the detection alarm parameters in the configuration software.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...