1 trong số 1

Mitsubishi Electric Q64TCRT MELSEC Q Series Platinum Resistance Temperature Control Module

Mitsubishi Electric Q64TCRT MELSEC Q Series Platinum Resistance Temperature Control Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: Q64TCRT

  • Country of origin:Hoa Kỳ

  • Product Type: PLC Temperature Control Modules

  • Payment: T/T, Western Union

  • Weight: 1300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Engineered for highly stable closed-loop thermal processes, the Mitsubishi Electric Q64TCRT handles direct interface to platinum resistance thermometers within a MELSEC Q Series PLC backplane. This module operates as an intelligent function block, executing PID control loop calculations independently of the main CPU cycle to guarantee real-time thermal response. By integrating temperature measurement, PID computation, and transistor outputs on a single hardware footprint, the unit minimizes network latency and eliminates external transmitter hardware.

Features

  • Four independent temperature control channels supporting Pt100 and JPt100 platinum resistance thermometer inputs.
  • Built-in PID engine supporting auto-tuning, self-tuning, and manual tuning profiles.
  • Transistor outputs (sink type) optimized for direct switching of Solid State Relays (SSRs).
  • Dedicated heating/cooling control output mode per channel for active thermal regulation.
  • Sensor disconnection detection to prevent thermal runaway in fault scenarios.

Applications

  • Plastic extrusion and injection molding barrel thermal zone management.
  • Semiconductor wafer processing chambers and heating blocks.
  • Food processing and packaging heat-sealing operations.
  • Precision environmental chambers and industrial drying ovens.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number Q64TCRT
Compatible Series MELSEC Q Series
Number of Channels 4 channels
Sensor Input Types Pt100, JPt100 (3-wire resistance temperature detector)
Control Output Type Transistor output (Sink type), 24 VDC, 0.1A per point
Sampling Cycle 0.5 seconds for all 4 channels
I/O Points Occupied 16 points (Intelligent function module)
Internal Current Consumption 550 mA (5 VDC typical)
Country of Origin Japan
Shipping Weight (Calculated) 1.3 kg

Empirical Engineering Insights

Alternative Models & Compatibility

While the Q64TCRT uses platinum RTD inputs (Pt100/JPt100), sister modules like the Q64TCTT utilize thermocouple inputs. Ensure that your field sensing element matches the module interface precisely, as these modules are not interchangeable without rewiring and updating the buffer memory parameters in the GX Works PLC configuration.

Application Pitfalls & Engineering Notes

The integrated transistor outputs are rated for 0.1A at 24 VDC. Under no circumstances should inductive contactors or high-wattage heater loads be connected directly to these outputs. Always route the transistor outputs to intermediate solid-state relays (SSRs) or interposing relays to prevent thermal degradation of the internal optocouplers.

Commissioning & Wiring Tips

Use 3-wire shielded cables for all RTD connections to ensure automatic lead-wire resistance compensation. Keep the sensor input lines isolated from high-voltage AC lines and motor variable frequency drive (VFD) output cables. Ground the cable shields at a single point on the PLC side to mitigate high-frequency electrical noise from corrupting the PID sampling process.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Isolate and lock out all main system power sources before installing, removing, or wiring the module. Ensure any residual field-side voltage on the 24 VDC heater circuit is fully de-energized to prevent circuit card damage or electrical shock during installation.

1
Mount the module firmly onto the MELSEC Q series base unit, ensuring the lower module fixing projection is locked into the slot and the unit is securely fastened with the module fixing screw.
2
Wire the RTD inputs to the 18-point terminal block using crimp-type terminal lugs to ensure a gas-tight, vibration-resistant connection. Ensure no loose wire strands bridge adjacent terminals.
3
Connect the external 24 VDC power supply to the designated terminals to drive the transistor control outputs, verifying correct polarity before restoring power to the backplane.

What sensor types are supported by the Q64TCRT?

The module natively supports 3-wire Pt100 and JPt100 platinum resistance thermometer sensors across all four input channels.

Does this module require an external power supply?

Yes, an external 24 VDC power supply is required to power the integrated transistor control outputs.

What is the response rate of the built-in control loops?

The module features a sampling cycle of 0.5 seconds to process calculations and update control outputs for all four channels.

Can the Q64TCRT execute heating and cooling control simultaneously?

Yes, each channel can be configured for dual-action heating and cooling control, occupying adjacent output points to drive heating elements and cooling valves.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...