Description

The Omron CJ1W-MAD42 is a high-density analog input/output module developed for the SYSMAC CJ1 programmable logic controller series. This module handles both analog-to-digital and digital-to-analog conversions within a single slot, providing a space-efficient solution for instrumentation tracking and closed-loop process hardware interfaces. It features multiple isolated channels configured to receive and transmit standard industrial current and voltage signals. The unit communicates directly via the CJ-series backplane bus to exchange raw binary data values with the CPU module. It is engineered for industrial processing, temperature modulation, and variable speed drive control across diverse automation infrastructures.

Features

  • Combined analog input and analog output functionality in a single-slot module.
  • Support for independent configuration of voltage and current signal ranges per channel.
  • High-speed A/D and D/A conversion rates synchronized with the backplane processing cycles.
  • Built-in diagnostics including disconnection detection for current input ranges.
  • Detachable terminal block allows simplified maintenance and pre-wiring tasks.
  • Internal data scaling and filtering capabilities manageable directly via CPU memory allocation.

Applications

  • Variable frequency drive speed and torque reference modulation.
  • Temperature regulation loops in extrusion and packaging machinery.
  • Level control and pressure instrumentation reporting in water treatment plants.
  • Proportional valve control and positioning feedback setups.
  • Parameter monitoring in data acquisition and industrial SCADA setups.

Technical Specifications

Input/Output Capacity

Parameter Specification
Number of Analog Inputs 4 channels
Number of Analog Outputs 2 channels
Input Signal Ranges 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA
Output Signal Ranges 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA

Performance and Accuracy

Parameter Specification
Resolution 1/4000 (standard mode), 1/8000 (high-resolution mode)
Conversion Time 1.0 ms / channel max. (standard mode)
Input Overall Accuracy Voltage: $\pm$0.2% of F.S., Current: $\pm$0.4% of F.S. (at 25 Celsius)
Output Overall Accuracy Voltage: $\pm$0.3% of F.S., Current: $\pm$0.5% of F.S. (at 25 Celsius)
Input Impedance Voltage Input: 1 M$\Omega$ min., Current Input: 250 $\Omega$ rated
Output Maximum Load Current Voltage Output: 5 mA
Output Maximum Load Resistance Current Output: 350 $\Omega$

Power Requirements and Physical

Parameter Specification
Internal Current Consumption 5 VDC at 0.58 A max.
External Power Supply Requirements 24 VDC +10% / -15% at 0.1 A max.
Ambient Operating Temperature 0 to 55 Celsius
Ambient Operating Humidity 10% to 90% RH (non-condensing)

Connections / Interfaces

Terminal Pin Function Terminal Pin Function
A1 Input 1 (+) B1 Input 2 (+)
A2 Input 1 (-) B2 Input 2 (-)
A3 AG (Input 1/2 Common) B3 AG (Input 1/2 Common)
A4 Input 3 (+) B4 Input 4 (+)
A5 Input 3 (-) B5 Input 4 (-)
A6 AG (Input 3/4 Common) B6 AG (Input 3/4 Common)
A7 Output 1 (+) B7 Output 2 (+)
A8 Output 1 (-) B8 Output 2 (-)
A9 External 24 VDC (+) B9 External 0 VDC (-)
A10 NC (Not Connected) B10 Frame Ground (FG)

Installation Guidelines

  • Mounting Method: Slide the module connectors directly onto the CJ-series backplane guide rail. Push down the top and bottom locking sliders until they click firmly into place.
  • External Power Connection: Connect a stabilized external 24 VDC power source to terminals A9 and B9 to drive the internal analog conversion circuits.
  • Signal Shielding: Use twisted-pair shielded cables for all analog I/O channel signal lines. Connect the shield braid to the functional or frame ground (B10) on the terminal block.
  • Cable Routing: Maintain a distance of at least 100 mm between analog signal cables and high-voltage power lines or inverter switching cables to eliminate induction noise.
  • Unused Channels: Short-circuit the positive and negative terminals of any unused analog input channels, or disable the channel entirely in the system parameter layout to suppress floating signal errors.

FAQ

  • Does this unit require an external power supply to operate?
  • Yes, it requires an external 24 VDC power supply connected to the designated terminal block pins to power the analog output and conversion circuitry.
  • Can I mix voltage and current configurations on the input channels?
  • Yes, each input channel can be independently selected and configured for voltage or current parameters via the PLC system settings.
  • What happens to the current inputs if a wire break occurs?
  • When set to a 4 to 20 mA range, the unit can detect a disconnection fault and sets a corresponding error flag in the memory area of the CPU.
  • Is it safe to unplug the terminal block while the PLC is processing data?
  • While the terminal block is detachable for simple maintenance, it is highly recommended to isolate the main system rack power before removing the terminal assembly.
  • Can this unit be mounted on any slot of a CJ-series expansion rack?
  • Yes, it can be mounted to any available slot on a standard CJ1-series CPU rack or expansion rack, provided the total power budget of the power supply module is not exceeded.
  • How is the choice between standard and high-resolution modes set?
  • The selection is done via the module parameter configurations using CX-Programmer software before transferring the project to the CPU.
  • What is the maximum load resistance supported on the current outputs?
  • The analog current output circuits support a maximum external loop load resistance of 350 $\Omega$.
  • How are the raw analog inputs mapped to the CPU memory?
  • The module utilizes allocated Special I/O Unit memory areas (CIO and DM words) determined by the unit number switch on the front panel.
  • What is the significance of the AG terminals?
  • The AG pins represent the Analog Ground connections, which serve as the common reference point for the adjacent isolated signal channels.
  • Are the analog input channels isolated from one another?
  • The analog inputs are isolated from the internal PLC digital circuitry, but channels share a common analog ground return layout.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám
Country of origin
Nhật Bản
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...