1 trong số 1

Omron G3PE-245B-3N G3PE Series 3-Phase Solid State Relay

Omron G3PE-245B-3N G3PE Series 3-Phase Solid State Relay

Only 8 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: G3PE-245B-3N

  • Country of origin:Nhật Bản

  • Product Type: Solid State Relays

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Providing precise, low-noise thermal regulation in demanding industrial environments, the Omron G3PE-245B-3N acts as a heavy-duty three-phase solid-state contactor engineered for high-frequency heater switching. Designed with a built-in heat sink and integrating advanced phototriac isolation, this device ensures safe galvanic separation between the control logic and high-power load circuits. The integrated zero-cross function suppresses electromagnetic interference by synchronizing load activation with the AC voltage zero points, making it highly compatible with noise-sensitive automation environments.

Features

  • Three-Phase Control: Equipped with 3 switched poles (3-element configuration) for comprehensive load isolation.
  • Zero-Cross Switching: Minimizes electrical noise and surge currents during initial power-up states.
  • Robust Isolation: High-performance phototriac coupler protects PLC/controller outputs from load-side transients.
  • Physical Durability: Solid-state construction eliminates mechanical wear, dramatically extending operational lifetimes compared to traditional electromagnetic contactors.
  • Convenient Terminal Layout: Heavy-duty screw terminals support secure ring and fork crimp connections.

Applications

  • Plastic injection molding and extrusion barrel heating
  • Industrial reflow ovens and industrial drying systems
  • Semiconductor manufacturing thermal chamber controllers
  • Packaging machinery shrink tunnels and sealing bars

Technical Specifications

Manufacturer Omron
Model Number G3PE-245B-3N
Device Type 3-Phase Solid State Relay (Heater Control)
Number of Elements 3-phase, 3-element
Rated Control Voltage 12 to 24 VDC
Operating Voltage Range 9.6 to 30 VDC
Input Current 10 mA max. (at 24 VDC)
Must Operate Voltage 9.6 VDC max.
Must Release Voltage 1 VDC min.
Rated Load Voltage 100 to 240 VAC (50/60 Hz)
Load Voltage Range 75 to 264 VAC (50/60 Hz)
Load Current 45 A (at 40 degC)
Minimum Load Current 0.5 A
Inrush Current Resistivity 440 A (60 Hz, 1 cycle)
Permissible I2t 1260 A2s
Applicable Load Capacity 15.5 kW (at 200 VAC)
Isolation Method Phototriac
Zero Cross Function Equipped
Terminal Structure Screw terminal
Shipping Weight (Calculated) 3.0 kg

Connections and Interfaces

Terminal Designation Terminal Class Description / Function
A1 (+) / A2 (-) Input Terminal DC Control Voltage Input (12 to 24 VDC trigger signal)
L1 / L2 / L3 Load Line Input 3-Phase AC power line input connections (100 to 240 VAC)
T1 / T2 / T3 Load Output 3-Phase AC power connection directly to the heating elements

Empirical Engineering Insights

Alternative Models & Compatibility

The "3N" suffix denotes a 3-phase, 3-element controller which switches all three distinct phases. If replacing older 2-element models (such as the G3PE-245B-3, which only switches two phases while passing the third directly), verify panel wiring diagrams. The 3-element version provides superior isolation and meets stricter safety codes requiring all phase lines to be interrupted during off-cycles.

Application Pitfalls & Engineering Notes

Solid state relays generate approximately 1.5 Watts of heat per Ampere of load current. When installing this 45 A unit in fully enclosed control panels, calculate total thermal load and ensure adequate air circulation or force-cooling. Ambient temperature inside the panel must not exceed 40 degC to maintain the full 45 A rating without derating the device.

Commissioning & Wiring Tips

To prevent localized overheating and terminal failure under high current loads, use crimp-style closed-loop ring terminals for the main load lines (L1/L2/L3 and T1/T2/T3). Ensure all load terminals are tightened to a torque rating between 1.47 and 2.45 N-m. Periodically inspect connection torque during routine plant maintenance cycles.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present on the main circuit terminals. Disconnect and lock out all upstream primary power supplies before executing installation, maintenance, or wiring procedures on this equipment. Verify residual voltage on all terminals using an appropriately rated digital multimeter.
1
Mount the unit vertically on a standard 35mm DIN rail or directly to a metallic back panel using the integrated mounting screw holes. Ensure the integrated heat sink fins are oriented vertically to facilitate optimal natural convective airflow.
2
Wire the 12 to 24 VDC control input line from your PLC, temperature controller, or safety logic solver to the A1 (+) and A2 (-) terminals.
3
Connect the incoming 3-phase power line utility supply wires to the input terminals labeled L1, L2, and L3 using high-temperature rated industrial wire.
4
Route the load output terminals T1, T2, and T3 to the heating element terminals. Double-check that all phase paths are configured correctly relative to delta or star heater wiring configurations.

What does the 3N suffix signify on this model?

The 3N suffix indicates that this G3PE model is a 3-phase, 3-element unit. It controls and switches all three power phases to the load, satisfying applications that require total isolative phase switching.

Does this solid state relay require an external heat sink?

No, the G3PE-245B-3N comes equipped with an integrated heat sink designed to dissipate heat generated during high-current operation up to its rated 45 A load at 40 degC ambient temperature.

What is the purpose of the built-in zero-cross function?

The zero-cross function switches the relay on when the AC load voltage is near zero. This minimizes load inrush current spikes and electromagnetic noise interference on nearby instrumentation wiring.

What is the correct terminal screw tightening torque for the load terminals?

To prevent high-resistance contact points and thermal failure, tighten the screw terminals on the main circuit lines (L1/L2/L3 and T1/T2/T3) to a torque value of 1.47 to 2.45 N-m.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Nhật Bản

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...