1 trong số 1

Omron G3PE-545B-3N G3PE Series Three-phase Solid State Contactor

Omron G3PE-545B-3N G3PE Series Three-phase Solid State Contactor

Only 2 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: G3PE-545B-3N

  • Country of origin:Nhật Bản

  • Product Type: Three-phase Solid State Contactors

  • Payment: T/T, Western Union

  • Weight: 0g

  • Dimensions: 150 x 150 x 110 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed for precise closed-loop thermal regulation, the Omron G3PE-545B-3N executes high-frequency switching of three-phase industrial resistive heaters. This solid-state contactor features an integrated heat sink to ensure optimal thermal dissipation under heavy continuous loads. Optimized for DIN rail mounting, the device incorporates a yellow LED operation indicator and a phototriac coupler for high dielectric isolation between the low-voltage control input and high-voltage power output. Built-in zero-cross circuitry reduces electromagnetic interference and inrush currents during initial turn-on cycles, extending heater element life in demanding industrial environments.

Features

  • Integrated Heat Sink: Monolithic design eliminates the need for external thermal calculations or mounting paste, simplifying installation.
  • Zero-Cross Triggering: Minimizes electrical noise generation by initiating conduction only when the AC load voltage passes through zero.
  • Phototriac Coupler Isolation: Delivers robust galvanic isolation between input logic and power circuits.
  • Dual Mounting Form Factor: Supports both standardized 35mm DIN rail tracks and direct panel screw mounting.
  • Status Diagnostics: High-visibility yellow LED provides real-time status of the input command logic.

Applications

  • Plastic injection molding and extrusion barrel heating systems.
  • Semiconductor wafer processing and packaging thermal chambers.
  • Industrial reflow ovens, drying kilns, and environmental test chambers.
  • Packaging heat-sealing machinery and food processing equipment.

Technical Specifications

Parameter Value
Manufacturer Omron
Model Number G3PE-545B-3N
Number of Phases Three-phase
Number of Poles 3-pole
Rated Input Voltage 12 to 24 VDC
Operating Voltage Range 9.6 to 30 VDC
Applicable Load Voltage 200 to 480 VAC (50/60 Hz)
Rated Load Current 45 A (at 40 degC ambient)
Insulation Method Phototriac coupler
Zero Cross Function Yes
Output ON Voltage Drop 1.8 V (RMS) max.
Leakage Current 20 mA max. (at 480 VAC)
Operate / Release Time 1/2 of load power source cycle + 1 ms max.
Dielectric Strength 2,500 VAC, 50/60 Hz for 1 min
Insulation Resistance 100 MOhm min. (at 500 VDC)
Ambient Operating Temperature -30 to 80 degC (no icing or condensation)
Ambient Operating Humidity 45% to 85% RH
Net Weight 2.0 kg
Shipping Weight (Calculated) 3.0 kg
Package Dimensions (Calculated) 150 x 150 x 110 mm

Connections and Interfaces

Terminal Terminal Designation Terminal Description / Function
Input (A1 / +) Positive control input terminal (12 to 24 VDC input)
Input (A2 / -) Negative control input terminal (Ground/Common)
Output (L1 / 1 / L2 / 3 / L3 / 5) Line voltage power source inputs (Three-phase AC supply side)
Output (T1 / 2 / T2 / 4 / T3 / 6) Load connection output terminals (Heater element connection side)

Alternative Models & Compatibility

The "N" suffix in the model code G3PE-545B-3N indicates a factory-fitted built-in heat sink. It is directly interchangeable with the G3PE-545B-3 (which requires an external heat sink or must be mounted to a thermally equivalent chassis). Note that this module uses zero-cross switching; if your application requires phase-angle control or precise proportioning of analog signals, you must transition to the Omron G3PW power controller series, as the G3PE cannot accept continuous analog current (4-20mA) loops without an external PWM converter.

Application Pitfalls & Engineering Notes

Solid-state devices exhibit leakage current even in the "OFF" state. The G3PE-545B-3N has a maximum leakage current of 20 mA at 480 VAC. Auxiliary mechanical contactors or isolation switches should always be placed upstream to completely de-energize the heater circuit during scheduled maintenance. Thermal degradation is the primary failure mode; ensure that panel cooling fans are sized to maintain ambient temperatures below 40 degC to prevent derating of the 45 A load capacity.

Commissioning & Wiring Tips

Always secure the load power terminals (M5 screws) with a precise torque of 2.0 to 2.4 N-m. Loose terminal connections lead to local overheating and terminal block meltdowns. To suppress induction noises in high-current applications, control signal wires (A1/A2) must be routed separately from the power supply lines (L1/T1, L2/T2, L3/T3). If utilizing direct panel mounting rather than a DIN rail, ensure the metal backplate of the heat sink has clean contact with the panel plate to assist thermal dissipation.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all upstream electrical power sources before attempting installation or maintenance. Confirm zero-voltage state on both input and load lines using a verified tester. Do not touch the integrated heat sink during or immediately after operation; temperatures can exceed 80 degC and cause severe burns.

1

Mount the SSR vertically on a standard 35mm DIN rail or directly onto a flat, rigid metal subpanel using M5 screws.

2

Ensure a minimum vertical spacing of 80mm above and below the device to facilitate unimpeded natural convection airflow through the heat sink fins.

3

Wire the control input logic to terminals A1 (+) and A2 (-). Observe polarity carefully to prevent logic drive failure.

4

Terminate the three-phase AC power lines to L1, L2, and L3, then wire T1, T2, and T3 to the heaters using ring terminals rated for 45 A load requirements.

What is the function of the zero-cross feature on this solid state contactor?

The zero-cross function forces the SSR to turn ON only when the load voltage is close to 0V. This significantly reduces inrush current surges, limits high-frequency electromagnetic noise, and prolongs the operational lifespan of the heater elements.

Does this model require a separate thermal compound during installation?

No. The G3PE-545B-3N model features a built-in heat sink. It is completely self-contained and ready to be mounted to a DIN rail without applying external thermal grease.

Can I use this contactor to control three-phase inductive motor loads?

No. The G3PE series is engineered and optimized for resistive heaters. Controlling highly inductive loads like motors can result in excessive back-EMF during turn-off, exceeding the dV/dt capability of the internal triacs and causing component failure.

How do I account for high ambient temperatures inside my control cabinet?

The rated load current is 45A at 40 degrees Celsius. If operating above this temperature, thermal derating curves must be applied. Ensure adequate ventilation or cabinet fan systems maintain air temperatures below the maximum operating limit of 80 degrees Celsius.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Nhật Bản

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...