1 trong số 1

Omron NX-DA3205 NX Series Analog Output Unit

Omron NX-DA3205 NX Series Analog Output Unit

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NX-DA3205

  • Country of origin:Nhật Bản

  • Product Type: Analog I/O Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 12 mm x 100 mm x 71 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Engineered for high-density distributed control environments, the Omron NX-DA3205 Analog Output Unit provides four high-precision analog output channels within a compact 12 mm slice form factor. Operating on the high-speed NX I/O Bus, this module enables precise current-loop control with a 15-bit resolution and synchronous I/O refreshing, making it highly suited for precise positioning, proportional valve modulation, and variable speed drive integration in Sysmac Studio architectures.

Key Features

  • Four high-precision analog outputs supporting standard 4 to 20 mA current loops.
  • 15-bit digital-to-analog conversion resolution ensures exceptional control granularity.
  • Synchronous I/O refreshing synchronizes output timing with the primary EtherCAT master cycle.
  • Ultra-fast conversion time of 0.04 ms per unit for dynamic, real-time application responses.
  • Tool-free Push-In Plus wiring technology reduces panel assembly time and prevents loose connections caused by vibration.

Industrial Applications

  • Proportional Valve Control: Smooth, repeatable modulation of hydraulic and pneumatic flow rates.
  • Motor Speed Regulation: Accurate frequency commands sent directly to variable speed drives (VFDs).
  • Process Control Loops: Setpoint transmission to remote regulatory controllers and actuators.
  • Heating Element Modulation: Interfacing with analog power regulators for precise temperature profiling.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number NX-DA3205
Series NX Series I/O System
Module Type Analog Output Unit
Number of Outputs 4 channels
Output Range 4 to 20 mA
Resolution 15-bit (1/30,000 full scale)
Conversion Time 0.04 ms per unit
Signal Processing Mode Synchronous I/O refreshing
I/O Connection Type Push-In Plus terminal block (8 terminals)
Degree of Protection IP20
Dimensions (W x H x D) 12 mm x 100 mm x 71 mm
Net Weight 0.07 kg (70 grams)
Shipping Weight (Calculated) 0.25 kg (including standard protective packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

If system specifications allow for fewer outputs, the NX-DA2205 serves as a direct 2-channel alternative. Note that standard 4 to 20 mA signals require correct programming of the upper and lower limit scaling within the Sysmac Studio configuration environment. Ensure that your NX Coupler Unit (e.g., NX-ECC201 or NX-ECC202) has firmware version 1.0 or later to ensure seamless communication with this analog slice.

Application Pitfalls & Engineering Notes

To maintain the integrity of the 15-bit D/A conversion, always route analog output lines away from high-voltage AC cables and motor feeder cables. Shielded twisted-pair (STP) cabling is strongly recommended to protect current signals from high-frequency electrical noise emitted by adjacent motor drives.

Commissioning & Wiring Tips

The Push-In Plus terminal block accepts solid wire or stranded wire terminated with ferrules. Avoid using bare stranded wire to ensure long-term physical stability in heavy vibration zones. Terminal block release keys can be depressed with a standard 2.5 mm flathead screwdriver to remove wires if necessary.

Installation Guidelines

CRITICAL WARNING: De-energize all primary system power supplies, including field power supplied to the NX bus, before inserting or removing the terminal block or changing the module configuration. Hot-swapping modules or working on active current-loop wiring can cause permanent hardware damage to the analog circuitry or field equipment.
  1. 1 Mount the NX-DA3205 unit directly onto a standard 35 mm DIN rail by clicking the unit’s locking hook securely onto the rail track.
  2. 2 Slide adjacent NX Series modules together until the internal side-connector interface pins are completely engaged.
  3. 3 Insert 4 to 20 mA loop wires directly into the designated Push-In Plus terminal points. Keep wire stripping length between 8 mm and 10 mm.
  4. 4 Connect the cable shield to a functional ground terminal point on the machine panel for optimal electromagnetic compatibility.

What is the output range of the NX-DA3205 analog unit?

The module outputs a standard linear current signal range of 4 to 20 mA across its 4 independent output channels.

Does this analog module support hot-swapping under power?

No. The Omron NX system does not support hot-swapping of individual slice modules while the bus power or field power supply is active.

What resolution does the NX-DA3205 use for D/A conversion?

It provides a 15-bit digital-to-analog conversion resolution, which translates to a precise scaling of 1/30,000 across the active output range.

What type of terminals are used for wiring on this unit?

It features an integrated Push-In Plus terminal block, allowing direct insert-termination of solid wires or ferruled stranded wires.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Nhật Bản

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...