1 trong số 1

Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670

Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670

Only 8 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA32-0BF0

  • Country of origin:Đức

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 x 35 x 15 cm (Estimated)

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

This is a Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670, an industrial-grade human-machine interface (HMI) designed for machine-level control and visualization tasks. This unit features a 12-inch TFT touch display and is powered by a Pentium III 500 MHz CPU. It is configured with 256 MByte of RAM and a 20 GB hard drive, pre-installed with the Windows 98 operating system. The device operates on a 115-230 V AC power supply and is supplied with a U.S. mains cable.

Features

  • 12-inch TFT color display with integrated touch screen
  • Intel Pentium III processor operating at 500 MHz
  • 256 MByte of installed RAM
  • 20 GB internal hard drive for data and application storage
  • Pre-loaded with Windows 98 (English version)
  • Flexible power supply input of 115-230 V AC

Applications

  • Machine control and operation panels
  • Process visualization and SCADA clients
  • Industrial data acquisition and logging
  • Factory automation control interfaces

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6AV7612-0AA32-0BF0
Series SIMATIC Panel PC 670
Product Type Panel PC
Display 12-inch TFT Touch Display
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 256 MByte
Storage 20 GB Hard Drive (HD)
Operating System Windows 98 (English)
Input Voltage 115-230 V AC (Supplied with U.S. Mains Cable)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 45 x 35 x 15 cm (Estimated)

Installation Guidelines

CRITICAL WARNING: Risk of Electric Shock

Disconnect all power sources before installation, servicing, or removal. All work must be performed by qualified personnel in accordance with local and national electrical codes. Failure to comply can result in severe injury or death.

  1. 1
    Panel Preparation: Ensure the mounting cutout in the control cabinet or panel is clean, deburred, and matches the required dimensions for the PC 670. Verify that all mounting clamps and the sealing gasket are present and undamaged.
  2. 2
    Mounting: Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly in a diagonal sequence to ensure a uniform seal against the panel surface, maintaining the specified IP rating. Do not overtighten.
  3. 3
    Grounding and Power Connection: Connect the protective earth (PE) terminal to the cabinet's main ground point using a low-impedance conductor. Connect the 115-230 V AC mains supply to the power input terminals, observing correct polarity for line and neutral.
  4. 4
    Peripheral and Network Connections: Connect any required peripherals such as keyboards, mice, or external drives to the appropriate ports. Connect network cables to the Ethernet port(s) for communication with PLCs or other network devices.
  5. 5
    Final Checks and Power-Up: Verify all connections are secure and that there is adequate clearance for ventilation around the unit's rear. Close the cabinet door, restore power to the panel, and power on the Panel PC to begin system configuration.

What operating system is installed on the 6AV7612-0AA32-0BF0?

This Panel PC comes pre-installed with the English version of Windows 98.

What are the screen specifications for this SIMATIC Panel PC?

The unit is equipped with a 12-inch TFT color display that features an integrated touch screen for user input.

What is the processor and memory configuration?

It is configured with a 500 MHz Pentium III CPU and 256 MByte of RAM.

Is the 6AV7612-0AA32-0BF0 a current product?

No, this model is classified as an obsolete product, making it suitable as a spare part for existing legacy systems.

What is the required input voltage for this device?

The Panel PC supports a flexible input voltage range of 115-230 V AC and is supplied with a U.S. mains cable.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...