Designed for distributed machine-mount installations, the IP2311-B400 fieldbus box facilitates direct, cabinet-free connection of digital signals in rugged industrial environments. This compact I/O module integrates 4 digital inputs and 4 digital outputs, routing them through standard M8 screw-type connectors for secure wiring to local sensors and actuators. Operating at data transfer rates up to 500 kBaud, the unit handles communications over distances up to 400 meters between modules using specialized LiYCY cabling. The fieldbus interface is established via robust 9-pin M23 connectors, allowing reliable integration into decentralized control architectures. System configuration and diagnostics can be performed seamlessly using the KS2000 software interface.

Features

  • Cabinet-free, decentralized mounting with IP67-rated environmental protection.
  • Four digital inputs (24 V DC) featuring a built-in 0.2 ms hardware input filter.
  • Four short-circuit-proof digital outputs rated up to 0.5 A per channel.
  • Tough, glass-fiber reinforced polyamide (PA6) housing material for industrial durability.
  • Direct integration with fieldbus systems via dual 9-pin M23 connections (male and female).
  • Flexible parameter assignment and diagnostic capabilities supported by the KS2000 configuration tool.

Applications

  • Automotive assembly and conveyor lines.
  • Material handling and sorting automation.
  • Food processing and high-moisture packaging zones.
  • Heavy machinery and decentralized process control.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model IP2311-B400
Module Type Fieldbus Box (Digital Input/Output)
Number of Channels 4 inputs + 4 outputs
Fieldbus Interface 1 x M23 female 9-pin, 1 x M23 male 9-pin
Data Transfer Rate 500 kBaud
Data Transfer Medium LiYCY 3 x 2 x 0.22 mm² (max. 400 m length)
Input Filter Time 0.2 ms
"0" Signal Voltage Range -3 to 5 V DC
"1" Signal Voltage Range 11 to 30 V DC (6 mA input current, EN 61131-2, type 2)
Sensor Power Supply From control voltage, max. 0.5 A total (short-circuit proof)
Rated Load Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (individually short-circuit proof)
Control Voltage Power Supply 24 V DC (20 to 29 V DC)
Box Supply Current 85 mA + sensor current (max. 0.5 A)
Power Connections Feed: 1 x M8 male 4-pin; Downstream: 1 x M8 female 4-pin
I/O Connections M8, screw type
Housing Material PA6 (polyamide)
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight approx. 350 g

Connections and Interfaces

Interface Type Connector Style Function
Fieldbus Input M23 9-pin Male Upstream fieldbus network connection
Fieldbus Output M23 9-pin Female Downstream fieldbus network connection
I/O Channels M8 Screw Type Direct connection for 4 sensors (inputs) and 4 actuators (outputs)
Power Feed M8 4-pin Male Incoming 24 V DC control and load power
Power Downstream M8 4-pin Female Loop-through power supply to adjacent modules

Installation Guidelines

  • Mount the module directly on flat machinery surfaces using the 2 pre-molded fixing holes (3.5 mm diameter, suitable for M3 screws).
  • Ensure all unused M8 and M23 connections are securely fitted with appropriate IP67 protection caps to prevent moisture ingress.
  • Maintain clear pathways for the fieldbus cabling to prevent tight bend radii and mechanical stress on the M23 connectors.
  • Verify that the total current draw of the sensors connected to the M8 ports does not exceed the maximum supply limit of 0.5 A.

Compliance and Certifications

  • CE Compliance
  • EMC Immunity: Conforms to EN 61000-6-2
  • EMC Emission: Conforms to EN 61000-6-4
  • Vibration Resistance: Conforms to EN 60068-2-6
  • Shock Resistance: Conforms to EN 60068-2-27

What is the primary function of the Beckhoff IP2311-B400?

The IP2311-B400 is a decentralized fieldbus box that interfaces 4 digital inputs and 4 digital outputs with a fieldbus network, enabling cabinet-free installation directly on machinery.

What is the maximum output current supported per channel?

Each of the 4 digital outputs supports a maximum current of 0.5 A, and all outputs are individually protected against short circuits.

Which software is used to configure this module?

Configuration, parameter assignment, and diagnostics for the IP2311-B400 can be executed using the Beckhoff KS2000 software interface.

What environmental protection ratings does this module have?

The module conforms to the EN 60529 standard with IP65, IP66, and IP67 protection ratings, making it highly dust-tight and resistant to water jets and temporary immersion.

What are the physical dimensions and weight of the module?

The module measures 30 mm x 210 mm x 26.5 mm (W x H x D) and weighs approximately 350 grams.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...