Description

The ATS01N109FT is a compact Soft Starter from the Altistart 01 range, engineered by Schneider Electric to ensure smooth starting and stopping of three-phase asynchronous motors. Rated for a nominal current of 9 A, this unit is designed to support a wide operational voltage range from 110 V to 480 V, covering motor power requirements from 1.1 kW to 4 kW depending on the application.

By limiting the starting torque and current surges, the ATS01N109FT prevents mechanical shock and voltage drops during motor startup. Its lightweight, low-profile construction makes it an ideal solution for applications where cabinet space is limited, providing a reliable and efficient method to extend the service life of motors and mechanical drive components.

Features

  • Smooth motor acceleration to reduce mechanical wear
  • Nominal current rating of 9 A
  • Supports a wide operational voltage range (110–480 V)
  • Compatible with asynchronous motors (1.1 kW to 4 kW)
  • Space-saving design for installation in tight enclosures
  • High reliability for industrial and commercial motor control

Applications

  • Small industrial conveyor systems
  • Fans and pumps
  • Packaging and bottling machinery
  • Automated gate and door control systems
  • Small-scale material handling equipment

Technical Specifications

Category Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 01
Product Type Soft starters
Current Rating 9 A
Operational Voltage 110 - 480 V
Motor Power Rating 1.1 - 4 kW
Dimensions 15.50 x 17.00 x 5.50 cm
Weight 0.34 kg
Product Phase Active
Commodity Code 84798997

Installation Guidelines

  • Mounting: Install the soft starter in a vertical orientation on a non-flammable surface to facilitate effective airflow and heat dissipation.
  • Clearance: Maintain the recommended clearance distances around the unit to prevent thermal overload.
  • Wiring: Connect the power supply and motor cables securely, ensuring torque settings meet the specifications provided in the manual.
  • Control: Use appropriate shielded cabling for control signals to prevent electromagnetic interference from power lines.
  • Environment: Ensure the operating environment is free from conductive dust, corrosive chemicals, and excessive moisture.

What is the operational voltage range of the ATS01N109FT?

The soft starter supports an operational voltage range from 110 V to 480 V.

What is the motor power capacity for this unit?

This model is compatible with asynchronous motors ranging from 1.1 kW to 4 kW.

What is the current rating for this soft starter?

The nominal current rating is 9 A.

Is this soft starter currently in production?

Yes, the ATS01N109FT is currently in the active phase of its product lifecycle.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...