1 of 1

Schneider Altistart 22 ATS22C11S6U Soft Starters

Schneider Altistart 22 ATS22C11S6U Soft Starters

Only 8 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS22C11S6U

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 13020g

  • Dimensions: 42cm x 33cm x 25,5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATS22C11S6U is a high-performance soft starter from the Altistart 22 range, designed to provide controlled acceleration and deceleration for three-phase asynchronous motors. Engineered to handle a rated current of 110 A across a wide input voltage range of 208-600 V, this unit supports motor power ratings between 30 HP and 100 HP. By regulating voltage and torque during the start-up phase, the ATS22C11S6U effectively minimizes mechanical stress on couplings and belts while reducing peak current demand on the power grid. It is a robust solution for enhancing the operational life of motor-driven equipment in heavy-duty industrial environments.

Features

  • Optimized for 110 A rated asynchronous motor current.
  • Wide voltage compatibility: 208 V to 600 V.
  • Supports a motor power range of 30 HP to 100 HP.
  • Integrated bypass contactor for reduced heat dissipation and improved efficiency.
  • Advanced protection features for motor and starter thermal management.

Applications

  • Centrifugal pumps and fluid management systems.
  • Industrial fans, blowers, and air handling units.
  • Conveyor belts and material handling machinery.
  • Compressors and agitators requiring smooth torque transitions.

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 22
Product Type Soft starters
Rated Current 110 A
Supply Voltage 208-600 V
Power Rating 30-100 HP
Dimensions 42.0 x 33.0 x 25.5 cm
Weight 13.02 kg
Product Phase Active
Commodity Code 84798997

Installation Guidelines

  • Mounting: The ATS22C11S6U should be mounted vertically to allow for optimal airflow through the internal heatsink.
  • Clearance: Ensure at least 100 mm of space above and below the unit to prevent thermal derating.
  • Wiring: Tighten power terminal connections to the manufacturer-specified torque to avoid overheating at high current loads.
  • Environment: Install in a location protected from moisture and conductive dust; for harsh environments, a NEMA/IP-rated enclosure is required.
  • Grounding: A secure chassis ground connection is essential to maintain electromagnetic compatibility and personnel safety.

What is the rated current of the ATS22C11S6U?

The soft starter is rated for 110 A.

What voltage range does this soft starter support?

It supports a wide input voltage range from 208 V to 600 V.

What is the motor power range for this unit?

This unit is suitable for motor power applications between 30 HP and 100 HP.

Does this model include a bypass contactor?

Yes, the Altistart 22 series features an integrated bypass contactor to optimize efficiency and minimize heat during steady-state operation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...