1 от 3

Allen-Bradley 1794-IB16 FLEX I/O Digital Sinking Input Module

Allen-Bradley 1794-IB16 FLEX I/O Digital Sinking Input Module

Only 4 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-IB16

  • Country of origin:Съединени щати

  • Product Type: Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 90g

  • Dimensions: 46 mm x 94 mm x 53 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The 1794-IB16 is a high-density discrete input hardware component designed for the FLEX I/O distributed network terminal system. This module functions as a 24V DC binary status processor, translating raw electrical voltage conditions from physical sensors into logical data bits utilized by a master logic controller. Operating within a sinking current configuration, the internal circuits route electricity from sourcing field-side elements to a centralized return node, managing reliable state classification across automated plant networks.

Equipped with sixteen non-isolated input channels, the device scales installation densities inside small control cabinet spaces while driving down overall hardware footprints. The 1794-IB16 handles signal data routing over wide networks by linking back to main processors via appropriate FLEX I/O network adapters over EtherNet/IP, ControlNet, or DeviceNet system buses. The module mounts directly into pre-wired terminal base assemblies, allowing for immediate bus linking and quick deployment in packaging systems, high-speed sorting facilities, pump station automation, and assembly machinery loops.

Features

  • Sixteen discrete sinking input channels enabling dense field sensor aggregation.
  • Nominal 24V DC operational envelope matching industrial proximity switches and limit devices.
  • Support for Removal and Insertion Under Power (RIUP) enabling hot-swapping during live bus states.
  • Individual front-panel light-emitting diode indicators displaying real-time logic states per point.
  • Configurable digital filter timing constraints to filter external inductive contact bounce.

Applications

  • Proximity sensor matrix tracking and pneumatic cylinder positioning loops.
  • Factory operator panel pushbutton stations and selector switch array inputs.
  • Conveyor track jam detection, alignment switches, and counting sensors.
  • Safety enclosure door interlocks and physical mechanical limit switch logging.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation / Allen-Bradley
Brand FLEX I/O
Part Number 1794-IB16
Module Type Digital Sinking Input Module
Number of Inputs 16 Channels, Non-Isolated
Nominal Input Voltage 24V DC
On-State Voltage Range 10V DC to 31.2V DC
On-State Current Range 2.0 mA minimum to 12.0 mA maximum
Nominal On-State Current 8.0 mA at 24V DC
Off-State Voltage Maximum 5.0V DC
Off-State Current Maximum 1.5 mA
Nominal Input Impedance 4.6 kilohms
FlexBus Current Draw 30 mA at 5V DC
Continuous Isolation Voltage 50V (Basic Insulation Type)
Input Filter Time (On to Off) Programmable (0.25 ms nominal to 8.0 ms maximum)
Operating Temperature 0 to 55 degC
Storage Temperature -40 to 85 degC
Relative Humidity 5% to 95% non-condensing
Country of Origin USA
Weight 0.09 kg
Dimensions 46 mm x 94 mm x 53 mm

Connections/Interfaces

Terminal Connection Block Node Function / Signal Path Allocation
Terminal 0 to Terminal 15 Discrete Sinking Input Channels 0 through 15
+V (External Supply Node) 24V DC Sourcing Sensor Operational Power Distribution Path
COM (External Supply Return) Common Direct Current System Ground Reference Rail

Installation Guidelines

DIN Rail Installation

Engage the upper retention hooks of the rear module housing onto the top track flange of standard 35 mm DIN rail lines. Push down and pivot the bottom portion of the enclosure inward until the embedded steel latch assembly locks around the lower tracking rail lip.

Terminal Base Seating

Align the integrated physical guide tracks located on the bottom face of the operational module with the receiving key slots on the pre-installed terminal base unit. Slide the hardware firmly into the interface socket matrix until the dual side latches click outwards to lock it in place.

Sinking Configuration Wiring

Wire external sourcing components directly to input points 0 through 15. Run the primary positive 24V DC distribution leg through the matching power tier of the terminal base block to keep standard potential profiles common across all connected sensor nodes.

Cabinet Cable Shielding

Keep low-voltage sensory signal lines separated from alternating current motor leads, active control power relays, and inductive drive fields within shared electrical conduit tracking to eliminate airborne electromagnetic signal distortion.

FAQ

What does the sinking circuit configuration imply for field sensors?

The sinking input configuration requires that all connected devices operate as current sourcing components, feeding voltage into the input points.

Are individual input channels on this unit isolated from each other?

No, the sixteen distinct input points are non-isolated and reference a shared common signal return line inside the electronic module.

Can an automation engineer safely swap this device while power is applied?

Yes, the hardware includes removal and insertion under power capabilities, which allows for live replacement without disabling the wider bus adapter array.

Which terminal base variations accommodate this specific input block?

The module is paired with multi-tier terminal base blocks such as the 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, or 1794-TBN models.

How can an operator stabilize high-frequency chatter from mechanical switch loops?

The digital input filter response constants can be modified inside the engineering programming software to clear up messy input signals.

What parameters register as a reliable off-state condition?

A channel reads as an off-state when the voltage drops below 5.0V DC or the incoming loop current values fall under 1.5 mA.

Does this device require independent external power to process inputs?

Yes, a nominal 24V DC external electrical loop must be wired straight into the terminal base infrastructure to power the field-side sensing electronics.

What function do the yellow indicators on the top faceplate perform?

Each LED illuminates when its matching input point senses an active on-state voltage parameter.

Can this specific model accept alternating current voltage inputs?

No, this module processes low-voltage direct current parameters exclusively across a 10V DC to 31.2V DC range.

How does this hardware pass discrete data blocks to a central PLC?

The unit transmits channel data bits across the local FlexBus backplane to a network adapter, which maps the data into network registers.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял
Country of origin
Съединени щати
Power source
Постоянен ток

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...