1 от 1

B&R X20SC2212 X20 System Safe Digital Mixed I/O Module

B&R X20SC2212 X20 System Safe Digital Mixed I/O Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20SC2212

  • Country of origin:Съединени щати

  • Product Type: Digital Mixed Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

The B&R X20SC2212, part number X20SC2212, is a safety-oriented digital mixed I/O module designed for integration within the X20 system backplane communication architecture to execute fail-safe control logic. The electronic module incorporates 6 safe type A digital inputs paired with 6 dedicated pulse outputs for cross-fault detection monitoring, alongside 2 safe type B1 digital outputs rated at 24 VDC and 0.5 A. Actuation and switching behavior for the safety outputs utilize an Output Signal Switching Device (OSSD) design with a diagnostic test pulse width of less than 500 µs to guarantee rapid response times during safety demands. Power distribution across the internal circuitry runs on a nominal 24 VDC bus with integrated reverse polarity protection to prevent component damage from improper electrical installation.

Hardware Specifications

  • Module Type: Safety-related digital mixed I/O module
  • Input Configuration: 6 safe type A digital inputs
  • Output Configuration: 2 safe type B1 digital outputs, 6 pulse outputs
  • Nominal Voltage: 24 VDC
  • Permissible Voltage Range: 20.4 to 28.8 VDC (24 VDC -15% / +20%)
  • Digital Output Current Rating: 0.5 A per channel
  • OSSD Pulse Width: <500 µs
  • Integrated Protection: Reverse polarity protection
  • Operating Humidity Range: 5 to 95%, non-condensing
  • Storage Humidity Range: 5 to 95%, non-condensing
  • Transport Humidity Range: 5 to 95%, non-condensing
  • Shipping Weight: 2 kg

Engineering Notes

  • Cyclic data exchange across the X20 backplane handles the safety I/O image transmission via the openSAFETY protocol to ensure deterministic communication timings.
  • The 6 pulse outputs emit specific test patterns that feed back into the 6 safe type A digital inputs to continuously verify physical line integrity and diagnose short circuits across channels or to external potential lines.
  • Safe type B1 digital outputs execute internal dual-channel monitoring sequences to detect component failures, ensuring the module transitions to a defined safe state if an unrecoverable fault occurs.
  • The operational power window is strictly limited to 20.4 to 28.8 VDC; any fluctuation outside these parameters causes an undervoltage or overvoltage diagnostic fault register entry, disabling the safety outputs.

Field Guidelines

  • Backplane Communication Shielding: Ensure the X20 bus base components are securely snapped together on the DIN rail to maintain low-impedance grounding across the local backplane communication segments.
  • Cable Routing and Separation: Route safety sensor and actuator wiring cables in separate wire ducts from high-current AC or variable speed drive conductors to minimize electromagnetic interference on the OSSD pulse lines.
  • Shield Grounding: Ground all shielded cables used for remote safety sensors directly at the entry point of the control panel enclosure using a low-impedance grounding rail.
  • Connector Insulation and Termination: Ensure all field wiring connections utilize correct cross-section conductors and crimped wire ferrules to secure consistent contact force within the terminal block layout.

Technical & Procurement FAQ

Question: Is the X20SC2212 safety module hot-swappable within an active X20 I/O chassis segment?

Answer: Yes, the three-part modular design of the X20 system allows the electronic module to be hot-swappable without disconnecting the terminal block wiring or breaking the backplane communication loop of adjacent modules.

Question: What firmware matching requirements apply when replacing a legacy hardware revision of this module?

Answer: Firmware compatibility is managed through the automation software platform, which cross-references the safety configuration checksum to ensure complete functional matching before allowing cyclic data exchange to resume.

Question: What physical contents are included out-of-the-box with the specific part number X20SC2212?

Answer: The package contains the brand new original stock electronic module itself; the matching X20 bus base and X20 front terminal block must be ordered as separate accessories to complete the mechanical installation.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Жълто
Country of origin
Съединени щати
Power source
Постоянен ток

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...