1 от 1

BECKHOFF EL3413-0001 EtherCAT Terminal 3-Channel Power Measurement Module

BECKHOFF EL3413-0001 EtherCAT Terminal 3-Channel Power Measurement Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3413-0001

  • Country of origin:Германия

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Designed for precise utility-grade analysis, the EL3413-0001 functions as a highly integrated 3-channel power measurement terminal within the Beckhoff EtherCAT I/O system. This industrial-grade module enables comprehensive evaluation of 3-phase AC power grids by direct connection of voltages up to 690 V AC. It features galvanically isolated current inputs designed for adjustable ranges of 100 mA, 1 A, and 5 A, providing high-accuracy readings even in electrically noisy environments.

The EL3413-0001 power measurement terminal performs mains-synchronous conversion with a 16-bit resolution, calculating essential network parameters such as active, reactive, and apparent power, energy consumption, frequency, power factor (cos phi), and harmonic wave analysis. It is optimized for energy management systems, grid synchronization, and machine-level load monitoring, transferring all calculated values directly to the PLC or DCS via high-speed EtherCAT communication.

Features

  • Direct 3-phase power measurement for alternating voltages up to 690 V AC.
  • Galvanically isolated current inputs with adjustable ranges (100 mA, 1 A, 5 A) for potential-free installation.
  • Comprehensive data calculation including voltage, current, active/reactive/apparent power, energy, frequency, and harmonic waves.
  • High-speed mains-synchronous conversion with 16-bit resolution.
  • High electrical isolation of 4500 V for robust system protection.
  • Compact 12 mm terminal housing with integrated diagnostic LEDs.

Applications

  • Industrial power monitoring and plant-wide energy management systems.
  • Power quality and harmonic analysis in heavy manufacturing environments.
  • Load monitoring and predictive maintenance for large electric motors and drives.
  • Integration with renewable energy systems, wind power, and solar sub-stations.

Technical Specifications

CategoryTechnical ParameterValue
Manufacturer Beckhoff EL3413-0001
Technology 3-phase power measurement for alternating voltages Single-ended
Number of Inputs 4 x current, 3 x voltage Mains-synchronous
Measuring Voltage Max. 690 V AC 3-phase (ULX-N: max. 400 V AC) Adjustable: 100 mA, 1 A (default), 5 A (potential-free)
Resolution 1 microampere, 0.1 mV, 10 mW 16-bit
Measuring Error 0.5% relative to full scale value (U/I), 1% calculated value 4500 V
Current Consumption (E-bus) Typ. 160 mA IP20 / variable
Operating Temperature -25 to +60 degC -40 to +85 degC
Relative Humidity 95%, non-condensing Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm Approx. 100 g

Connections and Interfaces

Connection Type Conductor Specifications
Wiring Technology Spring actuation by screwdriver
Solid Conductor (e) 0.08 to 2.5 mm² (AWG 28 to 14)
Flexible Conductor (f) 0.08 to 2.5 mm² (AWG 28 to 14)
Ferrule Connection (a) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm
Power Contact Current Load Imax: 10 A

Installation Guidelines

  • Mounting: Install directly onto a standard 35 mm DIN rail conforming to EN 60715. Secure using the integrated lock.
  • Side-by-Side Mounting: Align and connect adjacent terminals using the integrated double slot and key connection system.
  • Wiring: Use solid, stranded, or ferruled wires. Fully depress the spring tension clamp using a standard flat-head screwdriver before inserting the wire, then release to clamp. Ensure correct stripping length (8 to 9 mm) to prevent exposed copper.

Compliance and Certifications

  • CE
  • RoHS Compliant

What is the primary function of the Beckhoff EL3413-0001?

The EL3413-0001 is an EtherCAT terminal designed for 3-phase power measurement of alternating voltages, capable of direct connection up to 690 V AC and monitoring current, voltage, active power, reactive power, frequency, and harmonic waves.

What current ranges does this EtherCAT terminal support?

The current measurement inputs are adjustable and support 100 mA, 1 A (default), and 5 A. The current inputs are galvanically isolated (potential-free).

What is the electrical isolation rating of the EL3413-0001?

The EL3413-0001 features an electrical isolation rating of 4500 V, providing robust protection between the power network inputs and the internal E-bus circuitry.

How is the EL3413-0001 wired?

The module uses spring-cage clamp terminal connections. It supports solid conductors from 0.08 to 2.5 mm² (AWG 28-14) and flexible conductors with ferrules from 0.14 to 1.5 mm² (AWG 26-16), requiring a stripping length of 8 to 9 mm.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Наскоро разгледани продукти

Технически знания

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...