1 от 1

BECKHOFF IP6022-B810 Fieldbus Box Serial Interface Module

BECKHOFF IP6022-B810 Fieldbus Box Serial Interface Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP6022-B810

  • Country of origin:Германия

  • Product Type: Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 210g

  • Dimensions: 30 mm x 175 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Designed for robust serial data transmission in demanding industrial environments, the BECKHOFF IP6022-B810 Fieldbus Box serves as a reliable interface for connecting RS422 or RS485 devices directly to fieldbus networks. This compact, decentralized module enables peer-to-peer serial communication, allowing devices such as barcode scanners, operator terminals, and measuring sensors to integrate seamlessly into high-level control systems.

The module supports configurable data transfer rates ranging from 1200 to 115,200 baud, with a factory preset of 9600 baud. To prevent data loss during high-speed operations, the IP6022-B810 features an internal buffer memory comprising a 128-byte receive buffer and a 16-byte transmit buffer. System configuration and parameterization are quickly handled via the KS2000 software tool, providing flexible process image mapping to fit specific application architectures.

Features

  • Supports standard RS422 and RS485 physical layer interfaces for flexible differential serial communication.
  • Adjustable baud rates up to 115,200 baud with hardware-level transmit and receive buffers.
  • Robust IP67-rated encapsulation prevents ingress of water, dust, and particulate matter.
  • Standard M12 and M8 connector interfaces simplify installation and eliminate the need for protective enclosures.
  • Integrated galvanic isolation up to 500 V protects sensitive control electronics from fieldbus loop interference.
  • Compact, space-saving polyamide housing with dual-point mounting designed for direct machine installation.

Applications

  • Factory automation and assembly line serial device integration.
  • Process control systems utilizing long-distance RS422/RS485 instrumentation.
  • Material handling systems for connecting barcode readers and weight scales.
  • Decentralized test and measurement setups requiring high environmental resistance.

Technical Specifications

CategoryTechnical ParameterValue
Manufacturer BECKHOFF IP6022-B810
Interface Type Serial Interface (RS422 / RS485) 1 (peer-to-peer connection)
Data Transfer Rates 1200 baud to 115,200 baud (9600 baud, 8N1 default) Max. 500 m (twisted pair)
Line Impedance 120 Ohm -7 to +12 V (to ground)
Data Buffer 128 bytes receive buffer, 16 bytes transmit buffer 3 x 8-bit user data, 1 x 8-bit control/status (up to 5 x 8-bit user data supported)
Nominal Voltage 24 V DC (-15% / +20%) 45 mA + connected sensor current (max. 0.5 A)
Electrical Isolation 500 V (RS485 to control voltage) 1 x M12 socket, 5-pin, B-coded
Power Ports Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin PA6 (polyamide)
Operating Temperature 0 to +55 degC -25 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529) EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission EN 61000-6-2 / EN 61000-6-4 30 mm x 175 mm x 26.5 mm
Weight approx. 210 g approx. 1.0 kg

Connections and Interfaces

Connection Point Connector Type Function / Pin Assignment
Bus Interface 1 x M12 socket, 5-pin, B-coded Fieldbus connection and network communication
Serial Connection M12, screw type RS422 / RS485 RxD and TxD data channels
Power Feed 1 x M8 male connector, 4-pin Control voltage feed (24 V DC)
Downstream Power 1 x M8 female connector, 4-pin Control voltage loop-through to adjacent modules

Installation Guidelines

  • Mounting: Mount directly to flat surfaces using the two 3.5 mm diameter fixing holes designed for M3 screws.
  • Grounding: Ensure the module is grounded properly through its mounting screws or dedicated functional earth connection to minimize EMC disturbances.
  • Cabling: Use shielded twisted-pair copper cables (minimum 2 x 0.25 mm²) for long-distance serial runs to maintain signal integrity over the maximum 500 m limit.
  • Tightening Torque: Hand-tighten all M12 and M8 connectors to ensure the IP67 sealing integrity without damaging the plastic threads.

Compliance and Certifications

  • CE
  • UL

What is the default serial configuration for the IP6022-B810?

The module is preset to 9600 baud, 8 data bits, no parity, and 1 stop bit (8N1), but it can be configured from 1200 to 115,200 baud.

What software is required to configure this Fieldbus Box?

Configuration, mapping, and parameterization of the serial interfaces are done using the Beckhoff KS2000 configuration software.

Does the IP6022-B810 require a protective enclosure?

No, thanks to its IP67-rated polyamide housing and sealed M12/M8 connections, it can be mounted directly onto machines in wet, dusty, or dirty environments.

What is the maximum distance supported for serial data transmission?

Using a high-quality shielded twisted-pair cable, the IP6022-B810 supports RS422/RS485 cable lengths up to a maximum of 500 meters.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...