Bently Nevada 3500/92-03-01-00 136188-01 Ethernet/RS232 Modbus I/O Module

Bently Nevada 3500/92-03-01-00 136188-01 Ethernet/RS232 Modbus I/O Module

Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/92-03-01-00 136188-01

  • Country of origin:Съединени щати

  • Product Type: Ethernet/RS232 ModbusI/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1260g

  • Dimensions: 241 mm x 24.4 mm x 242 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The Bently Nevada 3500/92-03-01-00 is a Communication Gateway Module designed for the 3500 Series Machinery Protection System. Its primary purpose is to provide continuous, high-speed communication capability for all rack-monitored values and statuses, enabling seamless integration with distributed control systems (DCS), programmable logic controllers (PLC), human-machine interfaces (HMI), and other plant automation systems.

The module features comprehensive communication interfaces, utilizing both Ethernet TCP/IP and serial channels (RS232) via the 136188-01 I/O module. It handles internal data collection by pulling current measured values, time stamps, module statuses, and alarm statuses from other monitor modules within the rack via a high-speed internal network. Additionally, the 3500/92 supports direct Ethernet communication with proprietary 3500 Rack Configuration Software and Data Acquisition Software. This specific variant features a Configurable Modbus Register Utility to map system data efficiently into host automation networks.

Features

  • Continuous collection of rack data, including current measured values with time stamps, module statuses, and alarm statuses.
  • Simultaneous communication capability over Ethernet TCP/IP and serial links.
  • Configurable Modbus Register Utility to customize register mapping for host systems.
  • High-speed internal network collection rate that updates all rack modules in less than 1 second.
  • Front panel LED indicators for immediate monitoring of module operational status (OK) and communication activity (TX/RX).
  • Backward compatibility with software features of the original 3500/90 module.

Applications

  • Steam and gas turbine vibration and status monitoring integration.
  • Compressor and pump protection data transmission to plant DCS.
  • Industrial machinery condition monitoring and predictive maintenance networks.
  • Power generation and petrochemical plant automation synchronization.

Ordering Information

  • 3500/92: Communication Gateway
  • 03: Ethernet/RS232 Modbus I/O Module
  • 01: Low Memory
  • 00: None Agency Approval Option
  • 136188-01: Ethernet/RS232 Modbus I/O Module Spare (Includes Firmware Upgrade Kit 126M4118-01)
  • 126M4118-01: Firmware Upgrade Kit

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Country of Origin USA
Power Consumption 5.0 Watts typical with Modbus RS232/RS422 I/O Module
Data Types Current measured values with time stamp, module statuses, current alarm statuses
Update Time Less than 1 second for all modules in the 3500 rack
OK LED Output Indicates when the 3500/92 is operating properly
TX/RX LED Output Indicates when the 3500/92 is communicating with other modules in the 3500 rack
BNC Host Protocol Ethernet TCP/IP connection to 3500 Configuration and Data Acquisition Software
Modbus Protocol Based on AEG Modicon PI-MBUS-300 Reference Manual, Remote Terminal Unit (RTU) transmission mode
Ethernet Link Speed 10 Mbps, conforms to IEEE 802.3
Ethernet Protocol Ethernet TCP/IP frame and Modbus/TCP
Ethernet Connection RJ-45 for 10BASE-T Ethernet cabling
Operating Temperature -30 degC to +65 degC (-22 degF to +149 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95% non-condensing
Main Board Dimensions (H x W x D) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in)
I/O Module Dimensions (H x W x D) 241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Main Board Weight 0.82 kg (1.8 lb.)
I/O Module Weight 0.44 kg (0.96 lb.)
Total Assembly Weight 1.26 kg (2.76 lb.)

Connections/Interfaces

Connector Pin Function
RJ-45 Jack 10BASE-T Ethernet TCP/IP and Modbus/TCP Interface
Serial Port (RS232) Modicon Modbus RTU Serial Communication Interface

Installation Guidelines

  • Firmware Verification: Ensure that older Communication Gateway main modules are upgraded using Firmware Upgrade Kit 126M4118-01 before installing the new 136188-01 I/O module.
  • Rack Insertion: Insert the main board into the designated communication slot of the 3500 rack, ensuring full seating and secure fastening of the chassis screws.
  • I/O Module Alignment: Install the 136188-01 I/O module directly behind the main module from the rear of the 3500 rack.
  • Cabling Constraints: Use standard 10BASE-T Ethernet cabling with RJ-45 connectors for network setups, limiting cable runs according to IEEE 802.3 metrics.
  • Environmental Control: Ensure operating ambient conditions do not exceed 65 degC and that ventilation paths on the 3500 chassis remain unobstructed.

Compliance and Certifications

  • cNRTLus
  • ATEX
  • IECEx

FAQ

What is the function of the 3500/92 module?

It acts as a communication gateway, exporting data from a 3500 machinery protection rack to external automation systems like PLCs and DCS.

Which interfaces are provided on the 136188-01 I/O module?

It provides an RJ-45 Ethernet connection and an RS232 serial interface.

What protocols can run over the Ethernet connection?

It supports Modbus/TCP protocol as well as the proprietary Bently Nevada host protocol for software applications.

How does this module differ from the older 3500/90 module?

It removes the fixed primary value Modbus registers and replaces them with a flexible Configurable Modbus Register Utility.

How long does it take for the module to refresh data from the rack?

The data collection rate varies by configuration but is guaranteed not to exceed 1 second for all modules.

What is the typical power consumption of this specific I/O setup?

The system typically consumes 5.0 Watts when equipped with the Modbus RS232 I/O module configuration.

Can I connect my 3500 Configuration Software through this gateway?

Yes, it allows Ethernet communications with the 3500 Rack Configuration and Data Acquisition Software packages.

What should I check if the TX/RX LED is dark?

Verify that the module is correctly seated and that the internal rack communication bus is active and functioning.

Is a firmware upgrade mandatory when swapping in a new 136188-01 interface?

Older main gateway modules require a firmware upgrade using kit 126M4118-01 to properly recognize the new I/O hardware.

What are the environmental storage limitations for this hardware?

The module must be stored within an environment ambient temperature range of -40 degC to +85 degC.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/92-03-01-00 136188-01 Ethernet/RS232 Modbus I/O Module

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял Сребърен
Country of origin
Съединени щати
Power source
Захранван с променлив ток

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...