  • Manufacturer: General Electric

  • Product No.: UR-67H

  • Country of origin:Канада

  • Product Type: Digital I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1150g

  • Dimensions: 16.3cm x 4.2cm x 21cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The GE Multilin UR-67H is a specialized digital input/output communication interface card developed for the Universal Relays (UR) platform. This high-density contact execution module provides 8 Form-A digital outputs designed to safely interface with heavy-duty switching apparatus, circuit breakers, and auxiliary field systems within medium-to-high voltage electrical substations.

The primary utility of the UR-67H is to transition internal relay protection algorithms into secure physical control outputs. Operating within compatible protection devices like the B30 Bus Differential Relay or T60 Transformer Protection System, it receives high-speed logic commands over internal backplane links to prompt trip or signal controls across external substation environments. The module utilizes non-monitoring, non-latching mechanical contacts to provide precise macro-level power system management without adding systemic auxiliary circuit overhead. Configuration, routing logic, and status mappings for the component are fully managed via EnerVista software suites.

Features

  • Form-A Standard Contacts: Integrated with 8 discrete Form-A (normally open) non-latching and non-monitoring mechanical relay outputs.
  • Universal Relay Synchronization: Fully compatible with a wide assortment of UR series protective relay frames, handling up to 64 contacts per total platform system.
  • EnerVista Software Support: Integrates seamlessly with EnerVista setup applications for contact assignment, testing, and operational lifecycle mapping.
  • Substation Hardened Architecture: Engineered for heavy industrial deployments, providing secure mechanical switching for power plant and utility systems.

Applications

  • Bus Differential Tripping Logic: Installed inside units like the B30 relay to manage high-speed physical breaker isolation commands.
  • Transformer Control Automation: Integrated with UR system configurations to dispatch automated auxiliary control actions for transformer equipment.
  • Industrial Interlocking Systems: Provides physical status interlocks between switchyard machinery, disconnect switches, and central control networks.

Technical Specifications

Parameter Specification
Manufacturer GE Multilin
Model Designation UR-67H
Product Series Universal Relays (UR) Series
Module Type Digital Input/Output Module
Output Contacts 8 Form-A Outputs
Contact Functionality Non-latching, Non-monitoring
Configuration Software EnerVista
Manufacturing Location Markham, Ontario, Canada
Module Net Weight 1.15 kg

Installation Guidelines

  • Complete Isolation: Disconnect all main power links, external operational voltage paths, and logic control sources before initiating card removal or installation procedures.
  • Static Hazard Mitigation: Always wear a properly connected electrostatic discharge (ESD) wrist strap to mitigate high-potential component damage during hardware handling.
  • Relay Compatibility Validation: Cross-reference the specific UR platform configuration breakdown or instruction manual order matrix; options with an "XX" indicate the slot was originally left blank, confirming space for physical field retrofit or module upgrades.
  • Card Slot Verification: Insert the module firmly into its designated horizontal slot guided by the internal chassis rails until the rear edge connector is completely seated. Tighten faceplate mounting hardware securely.
Key Features:

Does the UR-67H card feature circuit continuity monitoring or current detection?

No. The contacts on this specific module variant do not include circuit continuity monitoring, current detection, or mechanical latching functions.

What software application is utilized to configure the contact maps for this digital card?

The module parameters, contact routing rules, and status monitoring are configured utilizing EnerVista software.

Can this specific module be installed into a B30 bus differential relay chassis?

Yes. This option code appears across multiple Universal Relay configurations including the B30, where it delivers trip-rated digital contact outputs.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Черно
Country of origin
Канада

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...