1 от 1

Honeywell 51453328-501 UDA Series Additional Analog & Relay Card

Honeywell 51453328-501 UDA Series Additional Analog & Relay Card

Only 6 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51453328-501

  • Country of origin:Съединени щати

  • Product Type: Analyzer Expansion Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Providing extended output capabilities for continuous process monitoring systems, this hardware expansion board, the Honeywell 51453328-501, integrates directly into the host UDA2182 Universal Dual Analyzer chassis. This card increases the control and alarm-handling capabilities of your process analyzer by introducing supplementary auxiliary analog outputs and dedicated physical relay contacts, ensuring seamless signal transmission to distributed control systems (DCS) or auxiliary control loops.

Features

  • Expands host analyzer capabilities to support additional physical control and alarm loops.
  • Provides isolated analog output channels for highly reliable process variable retransmission.
  • Integrated dry relay contacts configurable for high/low alarms, diagnostics, or limit controls.
  • Ruggedized field terminal blocks designed for secure industrial wire terminations.
  • Plug-and-play form factor simplifies field upgrades and minimizes system downtime.

Applications

  • Municipal water treatment facilities using Honeywell UDA2182 multi-parameter analyzers.
  • Industrial boiler feed-water monitoring systems demanding auxiliary signal retransmission.
  • Chemical processing plants requiring automated hardwired shutdown actions via relay interlocks.
  • Wastewater neutralization and effluent monitoring systems.

Technical Specifications

Manufacturer Honeywell
Part Number 51453328-501
Series Compatibility UDA2182 Universal Dual Analyzer
Module Type Additional Analog Output and Relay Card
I/O Functionality Auxiliary Analog Output & Relay Contact Outputs
Installation Slot Internal Dedicated Option Slot
Shipping Weight (Calculated) 1.0 kg

Alternative Models & Compatibility

The 51453328-501 card is specifically engineered for the UDA2182 analyzer series. When replacing older module revisions or retrofitting legacy analytical instrumentation, confirm that the host analyzer's firmware supports the additional analog and relay configuration options in the setup menu. Ensure the host unit's power supply capacity aligns with the overall system card loading before installation.

Application Pitfalls & Engineering Notes

To prevent cross-talk and measurement instability, signal loop cables must be isolated from high-voltage AC lines. Do not run low-voltage analog signal wires inside the same conduit as high-current relay switched lines. Inductive load switching with the on-board relays requires external snubber protection to avoid transient voltage feedback to the card circuitry.

Installation Guidelines

CRITICAL WARNING

Disconnect all electrical power to the host analyzer and verify the absence of voltage before opening the enclosure door. Failure to isolate the power supplies can cause severe shock, card damage, or system-wide communication faults.

1 Power down the UDA2182 host analyzer and secure with lock-out/tag-out procedures.
2 Open the main housing and locate the designated option slot on the internal chassis.
3 Carefully align the edge connector of the 51453328-501 card with the motherboard socket and press firmly until fully seated.
4 Secure the card with mounting screws to prevent vibration-induced dislodgement.
5 Terminate the analog signal and relay loop cables onto the plug-in terminal blocks, ensuring correct polarity.

What is the primary function of the Honeywell 51453328-501 card?

It is an option board designed to expand the input/output capacity of a UDA2182 Universal Dual Analyzer, providing additional physical relays and analog outputs.

Does the UDA2182 require firmware upgrades after installing this card?

The card is designed to be auto-detected by standard UDA2182 firmware, but it is recommended to verify firmware compatibility and menu options if upgrading older analyzers.

Can I hot-swap this card while the analyzer is running?

No. Power down the host instrument completely before inserting or removing the 51453328-501 card to avoid physical damage to the module or host motherboard.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Съединени щати

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...