1 от 1

Omron D4BL-1CRA D4BL Series Guard Lock Safety-Door Switch

Omron D4BL-1CRA D4BL Series Guard Lock Safety-Door Switch

Only 6 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: D4BL-1CRA

  • Country of origin:Япония

  • Product Type: Guard Lock Safety Switches

  • Payment: T/T, Western Union

  • Weight: 800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Engineered for robust mechanical interlocking of industrial machine guards and safety doors, the Omron D4BL-1CRA provides heavy-duty physical containment of hazards until safe operating conditions are met. This model features a highly secure mechanical lock combined with a 24 VDC solenoid-activated release, ensuring that access panels remain locked even during sudden power loss. With its rugged die-cast aluminum housing and an IP67 environmental protection rating, the device is optimized for reliable operations under demanding factory conditions.

Features

  • Dual-Channel Detection: Equipped with an independent door open/closed detection switch and lock monitor switch contacts for complete safety loop feedback.
  • Four-Position Adjustable Head: Head mounting direction can be rotated in four orientations (ships with right-side mounting) to accommodate diverse machine layouts.
  • Robust Locking Force: High mechanical locking retention force designed to prevent accidental or forced guard entry during hazardous machine cycles.
  • Die-Cast Aluminum Housing: Heavy-duty metallic construction offers excellent resistance to impact, chemical washdowns, and physical wear.
  • Conduit Access: Dual PG13.5 conduit entry points simplify routing and segregation of control and solenoid power wiring.

Applications

  • Robot work cells and automated assembly lines requiring controlled access.
  • Heavy industrial machinery, including stamping presses, CNC enclosures, and packaging equipment.
  • High-inertia machine safety guarding where run-down times require delayed entry.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Number D4BL-1CRA
Product Type Guard Lock Safety-Door Switch
Interlock Classification Type 2 (EN ISO 14119)
Coding Level Low Level coded (EN ISO 14119)
Lock Method Mechanical lock / 24 VDC solenoid release
Built-in Switch Configuration 1NC/1NO (slow-action) + 1NC (slow-action)
Conduit Outlets PG13.5 (2-conduit style)
Head Mounting Options 4 adjustable directions (Right-side mounted at shipping)
Mechanical Durability 1,000,000 operations minimum
Electrical Durability 500,000 operations minimum (10 A resistive load at 250 VAC)
Operating Speed Range 0.05 to 0.5 m/s
Operating Frequency Max. 30 operations per minute
Degree of Protection IP67 (EN60947-5-1)
Net Weight 0.8 kg
Shipping Weight 2.0 kg

Connections and Interfaces

Contact Designation Action Type Functional Circuit Assignment
Door Open/Closed Detection 1NC / 1NO Safety circuit verification and non-safety auxiliary PLC state feedback
Lock Monitor Detection 1NC Direct safety circuit monitoring of the physical locking mechanism state
Solenoid Terminals Coil Drive 24 VDC control input for coil energization to release mechanical lock

Empirical Engineering Insights

Alternative Models & Compatibility

The D4BL series comprises mechanical-lock models (such as this D4BL-1CRA) and solenoid-lock variants. Because the mechanical-lock design relies on internal spring tension to secure the guard and requires electrical power (24 VDC) to release, it is the safest option for systems with prolonged machine run-down times. Ensure that replacement units match this physical profile, as swapping to a solenoid-lock style changes the safety-fault state logic under loss-of-power scenarios.

Application Pitfalls & Engineering Notes

To prevent premature mechanical failure, the actuator key must enter the switch head smoothly without vertical or horizontal binding. Do not use the safety switch as a physical mechanical stop for the door or gate; separate hard stops must be installed to absorb the impact of door closure. Keep the auxiliary release key stored in a secure location accessible only to authorized maintenance personnel, as its use bypasses all safety locking functions.

Commissioning & Wiring Tips

When wiring the PG13.5 conduits, use matching liquid-tight conduit fittings to maintain the IP67 integrity. Check that the terminal screws are torqued to the OEM-specified limits to prevent loose connections under high-vibration conditions. Verify that safety loop evaluation relays or safety PLCs monitor both channels to successfully detect any potential single-channel faults or short circuits.

Installation Guidelines

CRITICAL SAFETY WARNING Disconnect all electrical power supplies to the safety switch, actuator mechanism, and machine control circuits before initiating installation, physical alignment, or internal wiring. Lockout/tagout protocols must be strictly enforced. Residual kinetic hazards must be completely dissipated before testing.
  1. 1
    Mounting the Main Body: Securely bolt the switch body to the rigid, non-movable frame of the machinery using M5 screws. Ensure the mounting surface is flat to prevent mechanical distortion of the enclosure.
  2. 2
    Aligning the Actuator Key: Mount the corresponding actuator key (sold separately) to the moving door or guard. Align the key entry angle within the specified tolerance limits to prevent mechanical wear on the switch head entrance.
  3. 3
    Head Orientation Adjustment: If needed, remove the four head screws, rotate the head to the desired mounting direction (front, back, left, or right), and securely re-fasten the screws.
  4. 4
    Conduit and Wire Termination: Run multi-core safety cabling through the PG13.5 conduit openings. Use insulated crimp terminals on the wire ends, torque all internal connection terminals, and hand-tighten the cover screws to maintain environmental seals.

What is the differences between mechanical lock and solenoid lock on D4BL units?

Mechanical lock units like the D4BL-1CRA use spring force to lock the guard automatically when closed, requiring power to the solenoid to release it. Solenoid lock units require power to the solenoid to lock the guard, meaning they will unlock in a total power failure.

What size conduit openings are provided on the D4BL-1CRA?

This model is equipped with two PG13.5 conduit outlets to facilitate neat physical separation of safety circuit and solenoid power cabling.

Can I adjust the head orientation on this safety switch?

Yes. The switch head can be rotated to allow the actuator to enter from four different directions. It is set to right-side mounting by default from the factory.

Does the D4BL-1CRA have an integrated LED indicator?

No, this model does not feature a built-in operation indicator. All diagnostic feedback is processed via the physical safety contacts.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял
Country of origin
Япония

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...