Designed to deliver precise process thermal control in high-density panel configurations, the Omron E5CN-C2TU is a 1/16 DIN (48 x 48 mm) digital temperature controller engineered for industrial automation environments. This model utilizes a current output as its primary control output, making it highly compatible with modulating control devices such as silicon-controlled rectifiers (SCRs) and analog control valves. Featuring a multi-input architecture, it supports both thermocouples and platinum resistance thermometers (RTD) without requiring hardware reconfiguration. With built-in preventive maintenance functions, including an ON/OFF transition counter for the control outputs, this controller helps track relay degradation and schedule proactive maintenance cycles before field failures occur.

Key Features

  • Universal Input Configuration: Accommodates standard thermocouples and platinum resistance thermometers (Pt100/JPt100) within a single hardware variant.
  • Enhanced Processing Accuracy: Delivers precise PV indication accuracy of +/-0.3% for thermocouple inputs and +/-0.2% for RTD inputs.
  • Dual Auxiliary Outputs: Includes 2 independent auxiliary relay outputs for configuring safety limits, system interlocks, or process alarms.
  • PV/SV Status Display Function: Configurable to automatically alternate between the Process Value (PV) / Setpoint Value (SV) and active controller states such as auto/manual modes, RUN/STOP status, and alarm triggers.
  • Convenient Plug-in Design: The U-type configuration allows rapid controller body replacement from the front of the panel without disrupting terminal socket wiring.

Applications

  • Plastic extrusion and injection molding thermal zone management.
  • Industrial ovens, heat-treating chambers, and packaging seal jaw heaters.
  • Food processing pasteurizers, sterilizers, and tempering systems.
  • Environmental testing chambers and climate simulation systems.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model E5CN-C2TU
Product Class Basic-type Digital Temperature Controller (1/16 DIN)
Supply Voltage 100 to 240 VAC, 50/60 Hz
Dimensions 48 x 48 mm (depth depends on mounting socket)
Primary Control Output Current Output (4 to 20 mA DC / 0 to 20 mA DC)
Auxiliary Outputs 2 SPST-NO relay outputs
Input Formats Thermocouple or Resistance Thermometer (RTD)
Indication Accuracy Thermocouple: +/-0.3% of PV | RTD: +/-0.2% of PV
Base/Terminal Type Plug-in Model (Requires 11-pin socket)
Housing Color Black
Shipping Weight (Calculated) 1.1 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The E5CN-C2TU plug-in design is specifically intended for systems requiring rapid serviceability. It interfaces directly with standard Omron 11-pin sockets (such as P2CF-11 or P3GA-11). When replacing older E5CN generation controllers, confirm if the original unit was a direct screw-terminal type (E5CN-C2T) or a plug-in type (E5CN-C2TU); a standard terminal-block model cannot plug into an 11-pin base without replacing the housing and socket wiring assembly.

Application Pitfalls & Engineering Notes

Because this controller utilizes an analog current output (4-20 mA DC), pay close attention to the allowable load impedance of the receiving control device (e.g., SCR driver or modulating valve positioner). Exceeding the controller's maximum load resistance limit will cause output saturation and non-linear control loops. Additionally, ensure the sensor cabling is completely segregated from power distribution paths to prevent induced high-frequency electrical noise from degrading PV reading accuracy.

Commissioning & Wiring Tips

When using thermocouple inputs, always ensure that the correct cold-junction compensation is active and that only matched thermocouple compensation wires are used for panel routing. For 3-wire RTD configurations, verify that all three lead wires have identical electrical resistance; any imbalance between the A, B, and B' lines will introduce systematic offset errors in the PV reading.

Installation Guidelines

CRITICAL WARNING: SAFETY FIRST

Before installing or removing the controller body from its socket, ensure the mains power supply (100 to 240 VAC) and all auxiliary contact circuit voltages are fully de-energized. Failure to disconnect active electrical power before extraction can result in electrical arcing, damage to the controller internal logic boards, or severe personal injury.

1
Ensure the cutout dimensions in the control panel face are exactly 45.0 mm x 45.0 mm (+0.6/-0 mm tolerance) for standard 1/16 DIN mounting.
2
Secure the matching 11-pin socket (e.g., P3GA-11 for rear-mounting or P2CF-11 for DIN-rail/front-mounting) within your panel enclosure, following the specified terminal block wiring layout for power supply inputs on pins 5 and 6.
3
Align the keyway guide on the rear plug of the E5CN-C2TU controller with the center indexing hole of the wired 11-pin socket. Push the controller firmly inward until it seats flush and the securing side clips click into locked positions.

What is the primary control output of the E5CN-C2TU?

The E5CN-C2TU features an analog current output (typically 4-20 mA DC or 0-20 mA DC), which is designed for modulating actuators, SCR power control boards, or control valves.

Does this controller model have screw terminals directly on its casing?

No. The 'U' suffix in E5CN-C2TU indicates that it is a plug-in model. It requires an external 11-pin base socket (such as P2CF-11 or P3GA-11) for physical wiring connection.

What sensor types can be connected to this temperature controller?

This controller supports universal inputs, meaning it is compatible with standard thermocouples (such as K, J, T, E, L, etc.) and platinum resistance thermometers (RTDs like Pt100 and JPt100) selectable via the system menus.

How do the dual auxiliary outputs function on this controller?

The two auxiliary outputs are independent SPST-NO relay contacts that can be configured for process alarms (high, low, band limits), diagnostic error warnings, or basic interlock sequencing.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Япония

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...