1 от 1

Omron G9SX-EX041-T-RT G9SX Series Flexible Safety Expansion Unit

Omron G9SX-EX041-T-RT G9SX Series Flexible Safety Expansion Unit

Only 5 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: G9SX-EX041-T-RT

  • Country of origin:Япония

  • Product Type: Safety Relay Expansion Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 15.0 x 12.0 x 6.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Integrating seamlessly into modular safety architectures, the Omron G9SX-EX041-T-RT functions as a dedicated safety expansion unit designed to increase the number of safety outputs within a localized machine safety system. This expansion module operates under a 24 VDC nominal supply and features four OFF-delayed safety outputs alongside one auxiliary output, offering precise time-delay safety control when paired with a compatible G9SX Advanced Unit.

Key Features

  • Output Configuration: Provides four OFF-delayed safety outputs and one non-safety auxiliary output.
  • Modular Scalability: Connects directly to G9SX-series Advanced Units via a dedicated logical connection port.
  • Secure Connections: Equipped with robust screw terminals (RT) to ensure reliable electrical contact in high-vibration environments.
  • Diagnostic Feedback: Integrated LED status indicators simplify troubleshooting and field diagnostics.

Industrial Applications

  • Safety stop sequence delay control for robotic work cells.
  • Controlled deceleration monitoring for heavy rotating machinery and CNC spindles.
  • Multi-zone safety output expansion in packaging and material handling conveyors.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Code G9SX-EX041-T-RT
Module Type Expansion Unit (Safety Output Expansion)
Rated Supply Voltage 24 VDC
Operating Voltage Range -15% to 10% of rated supply voltage
Power Consumption 2 W maximum
Instantaneous Safety Outputs None
OFF-Delayed Safety Outputs 4 outputs
Auxiliary Outputs 1 output
Rated Load 250 VAC, 3A / 30 VDC, 3A (resistive load)
Rated Carry Current 3 A
Terminal Block Style Screw Terminals (RT)
Operating Time (OFF to ON) 30 ms maximum
Response Time (ON to OFF) 10 ms maximum
Vibration Resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Electrical Durability 100,000 cycles minimum (at rated load)
Mechanical Durability 5,000,000 cycles minimum
Net Weight 0.165 kg
Shipping Weight (Calculated) 1.50 kg (including protective over-boxing)
Package Dimensions (Calculated) 15.0 x 12.0 x 6.0 cm

Alternative Models & Compatibility

The G9SX-EX041-T-RT is designed as an expansion companion and cannot function as an independent safety relay. It must be paired with a G9SX-AD (Advanced) safety controller. It connects via a lateral logical expansion plug. Ensure the expansion cable connection is locked securely; a loose logical connector will register a system configuration fault (indicated by flashing error LEDs on the parent Advanced Unit).

Application Pitfalls & Engineering Notes

When installing multiple G9SX units side-by-side inside high-temperature panels, pay close attention to thermal dissipation. If the internal panel temperature exceeds 45 degC, maintain a minimum spacing of 10 mm between adjacent units or derate the rated load current to prevent thermal-induced degradation of the internal mechanical relays. All power distribution schemes must use SELV/PELV power supplies to shield the unit's logical signaling from transient high-voltage noise spikes.

Commissioning & Wiring Tips

Do not hot-plug or disconnect the lateral expansion cable while the system is powered. Doing so will immediately lock the G9SX parent controller into a critical error state, requiring a full power cycle to reset. The OFF-delay time on the expansion module is determined entirely by the setup on the master controller or the specific variant settings—ensure the timing configuration matches the risk assessment calculations for safety-critical stopping times before putting the system into production.

Installation Guidelines

CRITICAL WARNING

Disconnect all primary power sources before initiating installation, removal, or wiring changes. Ensure internal capacitance charges have fully dissipated. Failure to follow industrial safety protocols can result in electrical shock, catastrophic equipment damage, or unintended machine movement.

1
Mount the master G9SX Advanced Unit and the G9SX-EX041-T-RT on a standard 35 mm DIN rail inside an IP54 or higher rated industrial enclosure.
2
Remove the expansion connector cover on the side of the parent unit and connect the integrated ribbon/logical cable securely between the modules before clipping them onto the rail.
3
Wire the screw terminals utilizing appropriate ferruled cabling matching the maximum 3 A carry current rating, taking care to route safety outputs separately from noisy power lines.

Can the G9SX-EX041-T-RT operate as a standalone safety relay?

No. This module is a dedicated expansion unit and must be connected to a compatible G9SX Advanced Unit via the logical expansion connector to function.

What does the RT suffix indicate on this module?

The RT suffix designates that the device features standard screw terminal blocks for field wiring connections.

Are the safety outputs on this unit instantaneous or delayed?

All four safety outputs on this expansion module are OFF-delayed. It does not contain instantaneous safety outputs.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Япония

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...