1 от 1

Schneider Electric NSYCU2K ClimaSys CU Enclosure Active Cooling Unit

Schneider Electric NSYCU2K ClimaSys CU Enclosure Active Cooling Unit

Only 5 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: NSYCU2K

  • Country of origin:Франция

  • Product Type: Enclosure Active Cooling Unit

  • Payment: T/T, Western Union

  • Weight: 52000g

  • Dimensions: 999 mm H x 405 mm W x 237 mm D

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Overview

The Schneider Electric NSYCU2K is a heavy-duty, side-mounting electronic enclosure climate controller belonging to the specialized ClimaSys CU product family. Engineered to maintain rigorous thermal stabilization inside sealed electrical cabinets, this compressor-based system delivers a nominal cooling power of 2000 W under standard L35-L35 rating criteria. In volatile process environments such as oil and gas refining, thermal power generation facilities, and automated aggregate processing plants, excessive thermal pockets lead directly to the premature tripping or permanent failure of high-density PLCs, variable frequency drives, and system backplanes. The NSYCU2K mitigates these structural risks by forcefully extracting internal heat loads while maintaining a continuous environmental barrier. The dual-loop circuit layout isolates contaminated factory air from the clean interior loop, driving down heat-induced processing downtime and protecting high-value control assets.

Hardware Infrastructure & Fluid Dynamics

The mechanical architecture of this active cooling system is built upon a rigid, industrial-grade steel chassis finished in standard RAL 7035 grey coating. Designed specifically for indoor screw-mount integration on enclosure doors or side panels, it uses a closed-loop R134a refrigerant system charged with 0.54 kg of gas to achieve an Energy Efficiency Ratio (EER) of 1.9. The unit incorporates high-capacity motorized fans that move air through the internal circuit at 860 m3/h and the external ambient loop at 1050 m3/h. For automated configuration, an onboard digital electronic controller regulates system operation based on selectable parameters, adapting automatically to distinct thermal thresholds across 50 Hz and 60 Hz electrical networks.

Core Technical Parameters Matrix

Parameter Certified Performance Data
Model NSYCU2K
Brand Schneider Electric
Range ClimaSys CU
Mounting Type Side-mount or Door-mount (Indoor)
Rated Power Consumption 1080 W at L35-L35 / 1290 W at L35-L50
Nominal Cooling Power 2000 W at L35-L35 / 1510 W at L35-L50
Input Operating Voltage 230 VAC, 1-phase, 50/60 Hz
Full Load Rated Current 6.5 A
Peak Inrush Current 24 A
Integrated Gas Charge R134a (0.54 kg)
Target Temperature Set Window 20 to 55 deg C (50 Hz) / 20 to 50 deg C (60 Hz)
Internal Loop Protection IP55 conforming to IEC 60529
External Loop Protection IP34 conforming to IEC 60529
Sound Pressure Level 65 dB conforming to EN/ISO 3746
Maximum System Pressure 25 bar
Net Weight 52 kg
Physical Dimensions 999 mm Height x 405 mm Width x 237 mm Depth

Field Diagnostics & Application FAQs

Why does the system list two distinct cooling capacities (2000 W and 1510 W)?

Cooling output depends on thermal gradients. Under L35-L35 parameters (internal cabinet air and external ambient air both at 35 deg C), the unit outputs its full 2000 W capacity. When ambient plant temperatures rise to 50 deg C (L35-L50 conditions), the compressor works against a higher thermal head, reducing net sensible cooling output to 1510 W while power consumption climbs to 1290 W.

What specific protective electrical hardware must be installed upstream of this unit?

Due to the inductive startup profile of the compressor motor, which draws a transient 24 A inrush current, a dedicated thermal protection fuse rated at 10 A (Time-delay / Type T) or a magnetic motor circuit breaker with matching delay characteristics must be installed to prevent nuisance tripping during start-up cycles.

Can this unit operate reliably in high-dust or chemical fiber environments?

Yes, but it requires accessory hardware. While the internal circuit is sealed to IP55, the unsealed external circuit operates at IP34. For areas with high concentrations of airborne particulate matter, non-conductive dust, or fibers, field technicians must install the optional external circuit filter to keep the condenser fins clear and maintain proper heat transfer efficiency.

Field Commissioning & Structural Installation Guide

  • Mechanical Panel Preparation: Utilize the factory cutout blueprint to trace and execute precise intake and exhaust apertures on the side panel or door of the Spacial enclosure. Remove all metal shavings, smooth out raw cut lines, and treat the bare steel borders with zinc-rich anti-corrosion primer before proceeding with mechanical fastening.

  • Gasket Compression and Sealing: Apply the continuous polyurethane sealing strip around the rear chassis mounting perimeter without overlaps or gaps. Lift the 52 kg unit using mechanical hoist assists and secure it via the specified mounting screws through the cabinet wall. Tighten fasteners uniformly to ensure uniform gasket compression, establishing the certified IP55 internal loop barrier.

  • Airstream Path Clearances: To maintain optimal air movement profiles (860 m3/h internal / 1050 m3/h external), ensure internal panel components, wireways, or structural plates sit at least 150 mm away from the internal intake and exhaust vents. Externally, maintain a minimum clear radius of 500 mm to prevent the re-ingestion of hot exhaust air.

  • Condensate Management and Slope: Mount the cooling unit perfectly plumb in both horizontal and vertical planes onto a rigid structure. Misalignments or tilting can disrupt the internal gravity-fed condensation path, leading to localized water accumulation or moisture migration into the low-voltage areas of the industrial enclosure.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял
Country of origin
Франция

Наскоро разгледани продукти

Технически знания

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...