1 от 1

Siemens 6ES7716-2BA11-0BB4 SIMATIC Field PG M4 Industrial Programming Device

Siemens 6ES7716-2BA11-0BB4 SIMATIC Field PG M4 Industrial Programming Device

Only 3 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2BA11-0BB4

  • Country of origin:Германия

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

This Siemens 6ES7716-2BA11-0BB4 is a SIMATIC Field PG M4 Premium Plus, a ruggedized industrial programming device designed for commissioning, servicing, and maintaining automation systems. It is equipped with an Intel Core i7-35X0M processor, 8 GB RAM, and a 1 TB HDD for demanding engineering tasks. The unit features a 15.6-inch Full HD display and comes pre-installed with Windows 7 Ultimate SP1 (64-bit). This configuration includes combo licenses for STEP 7 Professional, WinCC Advanced, and STEP 7 Micro/WIN, along with an MPI cable for direct PLC connectivity. This model is supplied without an S5 interface or S5-EPROMMER.

Features

  • Powered by an Intel Core i7-35X0M processor with Turbo Boost technology up to 3.6 GHz.
  • Features a 15.6-inch Full HD (1920x1080) widescreen display for detailed visualization.
  • Equipped with 8 GB of RAM and a 1 TB SATA hard disk drive.
  • Pre-installed with Windows 7 Ultimate SP1 (64-bit) with multi-language support.
  • Includes combo licenses for STEP 7 Professional, WinCC Advanced, and STEP 7 Micro/WIN.
  • Built-in DVD RW optical drive for software installation and data backup.
  • Supplied with a UK power supply cable and an MPI interface cable.

Applications

  • PLC and HMI programming and configuration in industrial environments.
  • On-site commissioning and startup of automation systems.
  • Field-level diagnostics, troubleshooting, and system maintenance.
  • Mobile engineering workstation for control engineers and technicians.

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Field PG M4
Model Number 6ES7716-2BA11-0BB4
Product Type Premium Industrial Programming Device
PLM Status Phase-Out
Processor Intel Core i7-35X0M (4M Cache, 2.9 GHz, up to 3.6 GHz with Turbo Boost)
Graphics HD Graphic 4000
Memory (RAM) 1 x 8 GB
Storage 1 TB HDD SATA
Optical Drive DVD RW
Display Size 15.6 inch
Display Resolution Full HD (1920 x 1080)
Keyboard QWERTY (& German layout)
Operating System Windows 7 Ultimate SP1, 64-bit (EN/DE/FR/SP/IT)
Licensed Software STEP 7 Professional COMBO (V13/2010), WinCC Advanced COMBO (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
Software Version V13.0.1.0
Included Accessories Power supply cable for UK, MPI cable
S5 Interface / EPROMMER Not included
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
ECCN N

Installation Guidelines

CRITICAL WARNING: This is a sensitive electronic device. Always handle with appropriate Electrostatic Discharge (ESD) precautions. Ensure the device is operated in an environment free from excessive moisture, corrosive agents, and conductive dust.
  1. 1 Upon receipt, carefully inspect the Field PG and its accessories for any signs of physical damage incurred during transit. Report any damage immediately.
  2. 2 Connect the provided UK power supply cable to the Field PG and plug it into a stable, properly grounded AC power source. Avoid using ungrounded outlets or extension cords.
  3. 3 Power on the device and allow the Windows 7 operating system to load completely. Complete any initial system setup prompts if this is the first use.
  4. 4 Launch the "Automation License Manager" to verify the status of the pre-installed software licenses (STEP 7, WinCC, etc.). Transfer licenses if required, following Siemens procedures.
  5. 5 For PLC communication, use the included MPI cable to connect the Field PG's serial port to the MPI port of the target SIMATIC controller. Configure the communication interface settings within the TIA Portal or SIMATIC Manager software.
  6. 6 Always operate the Field PG on a clean, level, and stable surface to ensure proper ventilation and prevent accidental drops or impacts common in industrial settings.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Наскоро разгледани продукти

Технически знания

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...