1 z 3

ABB IMMFP12 Bailey infi 90 Multi-Function Processor Module

ABB IMMFP12 Bailey infi 90 Multi-Function Processor Module

Only 3 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: IMMFP12

  • Country of origin:Switzerland

  • Product Type: DCS Multi-Function Processor Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 600g

  • Dimensions: 35.56 x 177.80 x 298.45 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

IMMFP12 functions as a multi-loop analog, sequential, batch, and function-code controller within the INFI 90 OPEN system. It performs process control, data acquisition, and information processing while supporting peer-to-peer communication between intelligent modules.

The processor exchanges process data with analog and digital I/O modules through the I/O Expander Bus. It can communicate with up to 64 low-power I/O modules in any combination. The internal DMA circuitry transfers communication data directly to or from RAM without continuous microprocessor intervention.

Two general-purpose serial channels support station and external device communication. The module also provides Controlway communication, module bus operation, and a dedicated processor redundancy link.

A primary and backup processor can operate in a redundant configuration. The backup remains in hot standby and receives block output data from the primary processor. Control transfers to the backup processor if the primary processor goes offline.

Features

  • Multiple-loop analog control
  • Sequential and batch control execution
  • Function-code-based control strategy processing
  • Data acquisition and information processing
  • Peer-to-peer communication between intelligent modules
  • Primary and hot standby processor redundancy
  • Bumpless control transfer between redundant processors
  • Execute, configure, and error operating modes
  • DMA-assisted communication data transfer
  • Front-panel status and diagnostic LED indication
  • Combination stop and reset pushbutton
  • Nonvolatile storage of the module configuration

Applications

  • Multiple-loop analog process control
  • Sequential equipment control
  • Batch process control
  • Analog and digital I/O coordination
  • Process data acquisition
  • Control strategy information processing
  • Redundant process control units
  • Operator station communication
  • INFI 90 OPEN control system modernization
  • Compatible Network 90 system configurations

Connections/Interfaces

P1 Card Edge Connector

Connector Pin Function
1 +5 VDC
2 +5 VDC
3 -30 VDC or power supply status
4 Controlway B
5 Common
6 Common
7 +15 VDC
8 -15 VDC
9 Power Fail Interrupt
10 Unused
11 Controlway A or Module Bus
12 Unused

Pin 3 carries -30 VDC in early Network 90 systems. It carries the power supply status signal in newer Network 90 and INFI 90 systems.

P2 Card Edge Connector

Connector Pin Function
1 Data Bit 1
2 Data Bit 0
3 Data Bit 3
4 Data Bit 2
5 Data Bit 5
6 Data Bit 4
7 Data Bit 7
8 Data Bit 6
9 Bus Clock
10 Synchronization
11 Reserved
12 Reserved

All P2 data bits are true low.

P3 Card Edge Connector

Connector Pin Function Connector Pin Function
1 DCS A (-) 16 DCS A (+)
2 DCS B (-) 17 DCS B (+)
3 Redundancy Transmit (-) 18 Redundancy Transmit (+)
4 Redundancy Transmit Clock (-) 19 Redundancy Transmit Clock (+)
5 Redundancy Receive (-) 20 Redundancy Receive (+)
6 Redundancy Receive Clock (-) 21 Redundancy Receive Clock (+)
7 Receive A (-) 22 Receive A (+)
8 Receive B (-) 23 Receive B (+)
9 Clear to Send A (-) 24 Clear to Send A (+)
10 Clear to Send B (-) 25 Clear to Send B (+)
11 Transmit A (-) 26 Transmit A (+)
12 Transmit B (-) 27 Transmit B (+)
13 Request to Send A (-) 28 Request to Send A (+)
14 Request to Send B (-) 29 Request to Send B (+)
15 Digital Output (+) 30 Digital Output (-)

Installation Guidelines

  • Verify module mounting unit compatibility before installation.
  • Check whether the backplane supplies -30 VDC before setting jumper J5.
  • Use a grounded wrist strap when handling the circuit board.
  • Keep the module inside its static shielding bag until installation.
  • Handle the assembly by its edges and avoid touching circuitry.
  • Verify all SW3 and SW4 dipswitch settings before operation.
  • Verify jumpers J1 through J5 before inserting the module.
  • Use identical module addresses for redundant processors.
  • Use matching SW4 settings for redundant processors.
  • Verify matching firmware revisions in primary and backup processors.
  • Disconnect cabinet power before installing backplane dipshunts.
  • Install 24-pin dipshunts between associated I/O Expander Bus slots.
  • Keep Controlway-linked mounting units within the same cabinet.
  • Do not connect more than eight related mounting units in one cabinet.
  • Connect NTMP01, NIMP01, or NIMP02 termination hardware using the specified cables.
  • Confirm all cables connect to the assigned module mounting unit slot.
  • Seat the module firmly in the backplane connectors.
  • Secure the module using both faceplate latching screws.
  • Keep cabinet doors closed during operation.
  • Keep portable communication equipment at least 2 meters from the cabinet.
  • Operate and store the module in a noncorrosive environment.

Compliance and Certifications

  • CSA certified for use as process control equipment in an ordinary nonhazardous location.
  • Factory Mutual approved for use in Class I, Division 2 hazardous locations.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB IMMFP12 Bailey infi 90 Multi-Function Processor Module

What control functions does the module support?

The module supports multiple-loop analog, sequential, batch, and function-code control. It also performs data acquisition and information processing.

How many I/O modules can it communicate with?

The processor can communicate with up to 64 low-power analog and digital I/O modules through the I/O Expander Bus.

How does processor redundancy operate?

A 1 Mbaud redundancy link connects the primary and backup processors. The backup remains in hot standby and takes control if the primary processor fails.

Which serial interfaces are available?

The module supports two RS-232-C ports, or one RS-485 port and one RS-232-C port. Serial communication rates reach 19.2 kbaud.

What is the specified operating temperature range?

The specified ambient operating temperature range is 0 to 70 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Switzerland

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...