Basler Electric DECS-200-1L Digital Excitation Control System

Basler Electric DECS-200-1L Digital Excitation Control System

Only 1 item(s) left in stock
  • Manufacturer: Basler Electric

  • Product No.: DECS-200-1L

  • Country of origin:United States

  • Product Type: Digital Excitation Control Systems

  • Payment: T/T, Western Union

  • Weight: 6350g

  • Dimensions: 304 mm x 205 mm x 171 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The Basler Electric DECS-200-1L Digital Excitation Control System provides precision excitation control for synchronous generators by regulating the direct current applied to the generator exciter field. Equipped with a pulse width modulated (PWM) power stage, the system delivers high performance across non-linear load applications and supports output capabilities of 32 Vdc, 63 Vdc, or 125 Vdc at up to 15 Adc. Operating modes include Automatic Voltage Regulation (AVR) with 0.25% accuracy, Field Current Regulation (FCR/Manual mode), Var control, and Power Factor (PF) control.

The controller features true RMS single- or three-phase sensing for generator voltage, bus voltage matching, and generator current. Interface options consist of contact inputs, proportional ±10 Vdc or 4–20 mA inputs, a front-panel RS-232 port (COM0), a side RS-232 port for unit autotracking (COM1), and a side RS-485 port supporting Modbus RTU protocol (COM2). Integrated machine protection capabilities include generator overvoltage/undervoltage, field overvoltage/overcurrent, loss of sensing, loss of field, exciter diode monitoring (EDM), and overexcitation/underexcitation limiting.

Features

  • Microprocessor-based digital excitation control with pulse width modulated power stage
  • Single or three-phase true RMS sensing for generator and bus voltage
  • 0.25% voltage regulation accuracy over the load range
  • Four operating modes: Automatic Voltage Regulation (AVR), Field Current Regulation (FCR), Var control, and Power Factor (PF) control
  • Internal autotracking between modes for bumpless transfers
  • 20 standard preprogrammed stability selections and user customizable PID settings
  • Underfrequency compensation or V/Hz ratio limiter with adjustable corner frequency
  • Soft start voltage buildup with adjustable time rates
  • Reactive droop and reactive differential (cross-current) paralleling compensation
  • Integrated Exciter Diode Monitoring (EDM) for detecting open and shorted diodes
  • Sequence of Events Recording (SER) storing up to 127 event reports
  • Integrated COMTRADE-compliant oscillography logging up to 8 records
  • Front panel HMI with backlit LCD display, programming keys, and diagnostic LEDs
  • Multiple communication ports: RS-232 front (COM0), RS-232 side (COM1), and RS-485 side (COM2) with Modbus protocol

Applications

  • Excitation voltage and current regulation for synchronous generators
  • Utility paralleling power generation systems requiring Var or Power Factor control
  • Brushless generator exciter field control with diode health monitoring
  • Generator protection and overexcitation/underexcitation limiting

Ordering Information

Model Tracking Option Power Supply Option
DECS-200-1L 1 (Internal autotracking) L (24/48 Vdc)

Technical Specifications

Parameter Specification
Manufacturer Basler Electric
Model DECS-200-1L
Control Power Input 16-60 Vdc (24/48 Vdc nominal, Style L), Burden = 30 W
AC Operating Power Input (32 Vdc Output) 60 Vac nominal (56-70 Vac +/-10%), 1 or 3 phase, 50-500 Hz, 780 VA burden
AC Operating Power Input (63 Vdc Output) 120 Vac nominal (100-139 Vac +/-10%), 1 or 3 phase, 50-500 Hz, 1570 VA burden
AC Operating Power Input (125 Vdc Output) 240 Vac nominal (190-277 Vac +/-10%), 1 or 3 phase, 50-500 Hz, 3070 VA burden
Rated Continuous Field Voltage Output 32 Vdc, 63 Vdc, or 125 Vdc
Rated Continuous Field Current Output 15 Adc
Rated 10-Second Forcing Voltage Output 50 Vdc (32 Vdc mode), 100 Vdc (63 Vdc mode), 200 Vdc (125 Vdc mode)
Rated 10-Second Forcing Current Output 30 Adc
Minimum Field Resistance 2.13 Ohms (32 Vdc), 4.2 Ohms (63 Vdc), 8.3 Ohms (125 Vdc)
Generator Voltage Sensing Input 1 or 3 phase, ranges: 100V/50Hz (85-127V), 120V/60Hz (94-153V), 200V/50Hz (170-254V), 240V/60Hz (187-305V), 400V/50Hz (340-508V), 480V/60Hz (374-600V), 500V/50Hz (425-625V), 600V/60Hz (510-660V); Burden < 0.1 VA/phase
Bus Voltage Sensing Input 1 phase, ranges: 100V/50Hz (85-127V), 120V/60Hz (94-153V), 200V/50Hz (170-254V), 240V/60Hz (187-305V), 400V/50Hz (340-508V), 480V/60Hz (374-600V), 500V/50Hz (425-625V), 600V/60Hz (510-660V)
Generator Current Sensing Input 1A and 5A AC ranges ( metering/control & cross current compensation); Burden < 1 VA
Contact Inputs 11 dry contact switching inputs supplied with 24 Vdc
Analog Remote Set Point Inputs Selectable +/-10 Vdc or 4-20 mA
Contact Outputs Resistive: 7.0 A at 24 Vdc, 0.7 A at 48 Vdc, 0.2 A at 125 Vdc, 7.0 A at 120/240 Vac
AVR Regulation Accuracy +/-0.25% over load range at rated power factor
Operating Temperature -40 degC to +60 degC (-40 degF to +140 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Salt Fog Per MIL-STD-810E, Method 509.3 (100 hrs salt fog, 100 hrs drying)
Shock 15 Gs in three mutually perpendicular planes
Vibration 5-26Hz: 1.2Gs; 27-52Hz: 0.914mm double amplitude; 53-500Hz: 5.0Gs
Dimensions (H x W x D) 304 mm x 205 mm x 171 mm (12.0 in x 8.08 in x 6.76 in)
Weight 6.35 kg (14 lbs)

Connections/Interfaces

Connector Pin Function
BATT+ (B7) DC Control Power Input (+24/48 Vdc)
BATT- (B8) DC Control Power Input (-24/48 Vdc)
L (B9) AC Control Power Input Line
N (B10) AC Control Power Input Neutral
C (C4), B (C3), A (C2), GND (C1) Input Operating Power Connections and Chassis Ground
E1 (A1), E2 (A2), E3 (A3) Voltage Sensing Inputs
CTB 1AMP (B1), CTB 5AMP (B2), CTB COM (B3) Current Sensing Channel B
CTCC 1AMP (B4), CTCC 5AMP (B5), CTCC COM (B6) Cross Current Compensation Sensing Channel
A5, B3, A4, B1 Bus Voltage Matching Inputs
F+ (C5), F- (C6) Exciter Field Power Output
A6, A7 4-20 mAdc Auxiliary Analog Input
A8, A9, A10 +/-10 Vdc Auxiliary Analog Input (GND, V+, V-)
A11, A12 Stop/Start Relay Contacts
A13, A14 Watchdog Relay Contacts
A15, A16 Programmable Output Relay #1
A17, A18 Programmable Output Relay #2
A19, A20 Programmable Output Relay #3
A21, A22 Start Contact Input and Common
A23, A24 Stop Contact Input and Common
A25, A26 AVR Mode Select Contact Input and Common
A27, A28 FCR Mode Select Contact Input and Common
A29, A30 Raise Contact Input and Common
A31, A32 Lower Contact Input and Common
A33, A34 Pre-position Contact Input and Common
A35, A36 Unit/Parallel Operation Contact Input and Common
A37, A38 Var/PF Control Contact Input and Common
A39, A40 Secondary Unit Enable Contact Input and Common
A41, A42 Alarm Reset Contact Input and Common
A43, A44, A45 RS-485 Communication Output Port COM2 (A, B, C)
COM0 (Front Panel) RS-232 9-pin Sub-D Serial Port for local PC interface
COM1 (Side Panel) RS-232 9-pin Sub-D Serial Port for dual unit autotracking

Installation Guidelines

  • Grounding: Connect terminal C1 (GND) securely to the system chassis ground to ensure proper grounding and noise immunity.
  • Control Power Isolation: If dual control power sources are utilized, install an AC Control Power Isolation Transformer (Basler P/N BE31449-001) on the AC power input.
  • Inrush Current Mitigation: When powering from a source already at rated voltage levels, install an Inrush Current Reduction Module (ICRM-15) to limit startup inrush current.
  • Dual Unit Configurations: For redundant DECS-200 arrangements, connect units using interconnection cable P/N 9310300032 and install a DECS Freewheeling Diode Module P/N 9293600101.
  • Communication Wiring: Maintain RS-485 network cables within a maximum distance of 4,000 feet using recommended shielded twisted-pair cabling.
  • Voltage Sensing: Ensure potential transformers are installed if the line voltage exceeding 600 Vac is connected to the sensing terminals.

Compliance and Certifications

  • UL Recognized per Standard 508 (File E97035)
  • CSA Certified per Standard CAN/CSA-C22.2 No. 14 (File LR23131)
  • CE Compliant (EMC and LVD directives)
  • DNV Certified per Standard 2.4
  • GOST-R Certified
  • Byelorussian Certified
  • IEEE C37.90.1-1989 (Surge Withstand Capability and Fast Transient)
  • IEEE 421.3 (High Pot testing)
  • ISO 9001:2000 Registered
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Basler Electric DECS-200-1L Digital Excitation Control System

What is the primary function of the control system?

The control system regulates generator output voltage, vars, or power factor by controlling the DC excitation applied to the generator exciter field.

What power supply voltage ranges are supported by this model variant?

The DECS-200-1L model accepts a DC control power input range of 16 to 60 Vdc, with a 24/48 Vdc nominal rating.

What operating regulation modes are available on the device?

The device features Automatic Voltage Regulation (AVR), Field Current Regulation (FCR/Manual mode), Var control mode, and Power Factor (PF) control mode.

What communication protocols and ports are integrated into the unit?

The unit features a front RS-232 port (COM0) using ASCII commands, a side RS-232 port (COM1) for unit tracking, and a side RS-485 port (COM2) using Modbus RTU protocol.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizace HMI Bailey INFI 90 Symphony běžících na OpenVMS Alpha

Praktický průvodce výměnou zastaralých operátorských stanic Bailey Symphony běžících na OpenVMS Alpha. Porovnává emulaci Alpha, migraci OpenVMS na x86, přemostění OPC a postupnou modernizaci ABB.

Proč jsou údaje o údržbě nezbytné pro průmyslovou spolehlivost

Údaje o údržbě propojují pracovní příkazy, signály ze senzorů, historii majetku, náklady a znalosti techniků. Správné využití těchto dat zlepšuje plánování, spolehlivost, prediktivní údržbu, kontrolu...

Elektrické pohony navržené jako náhrada fluidních energetických systémů: praktický průvodce průmyslovou automatizací

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator společnosti SMC, mění průmyslové řízení pohybu tím, že nahrazují tradiční pneumatické a hydraulické systémy....

Matematické operace pomocí OpenPLC pro aplikace průmyslové automatizace

Tento článek vysvětluje, jak systémy PLC provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování, v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá booleovská logika s programováním PLC pomocí FBD: praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí booleovské logiky používaných při programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se nástroje jako pravdivostní tabulky,...

Booleovská logika v programování PLC: porozumění logickým hradlům FBD

Booleovská logika je základem každého programu PLC. Od jednoduchého řízení strojů až po komplexní systémy průmyslové automatizace logická hradla určují, jak řídicí jednotky reagují na měnící se...