Processing analog signals directly in harsh field environments is simplified with the EP3162-0002 EtherCAT Box. This IP67-rated decentralized module features two highly flexible, galvanically isolated analog inputs that are software-parameterizable for either voltage (-10/0 to +10 V) or current (-20/0/4 to +20 mA) signals on a per-channel basis. By executing analog-to-digital conversion directly at the sensor location, this module minimizes signal degradation over long wire runs, enabling clean 16-bit measurement resolution across distributed fieldbus networks.

The device features dual-channel isolation to eliminate ground loop issues, making it highly reliable in electrically noisy industrial applications. Connectivity is facilitated through robust, industry-standard M12 connectors for the sensor lines and M8 connectors for the EtherCAT fieldbus and power supply daisy-chaining. With integrated Distributed Clocks (DC) support, the module guarantees precise, synchronized data acquisition across large-scale industrial machinery.

Features

  • Two single-ended, individually parameterizable analog input channels.
  • Supports standard industrial signal ranges: -10 to +10 V, 0 to 10 V, -20 to +20 mA, 0 to 20 mA, and 4 to 20 mA.
  • Complete galvanic isolation between individual input channels for high signal integrity.
  • Fast analog-to-digital conversion time of approximately 100 microseconds per channel.
  • High-precision 16-bit digital resolution (including sign).
  • Distributed Clocks (DC) support for high-fidelity clock synchronization in time-critical tasks.
  • Rugged IP65/66/67 physical housing for direct mounting outside of control cabinets.

Applications

  • Decentralized process instrumentation and sensor monitoring in heavy industrial plants.
  • Hydraulics and pneumatic system pressure, flow, and temperature tracking.
  • Machine-mount data acquisition systems in automotive assembly and packaging lines.
  • Test bench environments requiring high-speed, synchronized analog measurements.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model EP3162-0002
Product Type EtherCAT Box (Analog Input)
Number of Inputs 2 single-ended (galvanically isolated channels)
Signal Type (Voltage) -10/0...+10 V (parameterizable per channel)
Signal Type (Current) -20/0/4...+20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Measurement Error < ±0.3% (relative to full scale value)
Conversion Time ~ 100 microseconds
Input Filter Limit Frequency 5 kHz
Bus Interface Connection 2 x M8 socket, shielded, screw-type
Input Connection Method M12 x 1, 5-pin, A-coded
Nominal Supply Voltage 24 V DC (-15% / +20%)
Power Connection Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Current Consumption (Us) 120 mA
Sensor Supply Us derived from auxiliary voltage, electrically isolated
Electrical Isolation 500 V (fieldbus to signal), 300 V (signal to signal)
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Weight approx. 165 g
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27

Connections and Interfaces

M12 Pin Connection Signal Assignment
Pin 1 +24 V DC Sensor Supply (Us)
Pin 2 Analog Input + (Voltage / Current)
Pin 3 GND Sensor Supply (Us)
Pin 4 Analog Input -
Pin 5 Shield / Functional Earth

Installation Guidelines

  • Mounting: Screw the module directly onto flat machine surfaces using the integrated mounting holes. Ensure the mounting plane is grounded.
  • Shielding: Use fully shielded M12 sensor cables and shielded M8 EtherCAT cabling to preserve signal integrity and prevent electromagnetic interference (EMI).
  • Power Daisy Chaining: When utilizing the downstream M8 power output, verify that the total current draw of downstream modules does not exceed the maximum power bus capacity.
  • Sealing: Unused M12 and M8 ports must be sealed with appropriate IP67 protection caps to maintain environmental integrity.

Compliance and Certifications

  • CE
  • UL

Can the EP3162-0002 measure both voltage and current on different channels simultaneously?

Yes, each of the two analog input channels on the EP3162-0002 can be independently parameterized via TwinCAT software. One channel can be set for voltage measurements (e.g., -10 to +10 V) while the other handles current loops (e.g., 4 to 20 mA).

What is the level of electrical isolation provided between the two input channels?

The EP3162-0002 features galvanic isolation up to 300 V between the individual input channels, as well as 500 V isolation to the EtherCAT fieldbus, minimizing the risk of ground loops.

Does this module require a control cabinet for installation?

No, with its IP65/66/67-rated enclosure, the EP3162-0002 is designed for direct machine mounting in wet, dusty, or harsh environments without needing an electrical enclosure.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...