1 z 1

Beckhoff IP2322-B510 Fieldbus Box

Beckhoff IP2322-B510 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2322-B510

  • Country of origin:Germany

  • Product Type: Fieldbus Box

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

To optimize distributed automation topologies, the Beckhoff IP2322-B510 functions as a ruggedized, field-mountable I/O hub that interfaces directly with CANopen industrial networks. By combining four digital inputs and four digital outputs within a single sealed housing, this module eliminates the physical footprint and wiring complexity associated with traditional terminal enclosure cabinets. Operating on 24 V DC, it provides high-capacity signal processing and high-current load actuation directly at the point of application, ensuring minimal signal degradation and rapid response times in demanding processing environments.

Features

  • Decentralized I/O Integration: Features 4 digital inputs and 4 high-capacity digital outputs to minimize control cabinet space.
  • Standardized CANopen Interface: Fully compliant communication interface supporting flexible baud rate selections for deterministic industrial control.
  • Robust M12 Connection System: Industry-standard threaded M12 connectors secure logical, sensor, and actuator connections against heavy vibration.
  • High-Current Actuator Drives: Digital outputs support loads up to 2 A per channel, ideal for driving hydraulic valves, solenoids, and contactors.
  • Fast Input Filtering: Integrated hardware input filter time of 3 ms ensures rapid, noise-immune signal acquisition from field sensors.

Applications

  • Direct machine-mount sensor and actuator arrays.
  • Material handling conveyors and automated sorting systems.
  • Robotic end-of-arm tooling and high-vibration assembly cells.
  • Pneumatic and hydraulic valve manifold control stations.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model Number IP2322-B510
Fieldbus Protocol CANopen
Input Channels 4 x Digital Inputs (24 V DC)
Input Filter Time 3 ms
Output Channels 4 x Digital Outputs (24 V DC)
Max. Output Current 2 A per channel
Nominal Power Supply 24 V DC (-15% / +20%)
Physical Connection M12 (threaded circular connectors)
Ingress Protection IP67 (when all ports are mated or capped)
Shipping Weight (Calculated) 2.00 kg

Connections and Interfaces

Connector Interface Functional Assignment
M12 (5-pin, A-coded) CANopen Bus In / Bus Out network connection
M8 / M12 (Power) Control voltage supply (Us) and auxiliary actuator voltage (Up)
M12 (I/O Channels) Dedicated connections for Digital Inputs (1-4) and Digital Outputs (1-4)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2322-B510 shares a standard mounting footprint with other legacy Beckhoff Fieldbus Box units. Note that if you are migrating from DeviceNet or PROFIBUS variants, the physical network configuration must be adjusted for the CANopen protocol stack. Integrated Node ID and baud rate selection are configured directly on the module via rotary switches located beneath the protective seal.

Application Pitfalls & Engineering Notes

While individual output channels are rated for a high 2 A continuous load, total module current capacity is limited by the power supply feed capabilities of the incoming cabling. Ensure that the source 24 V DC power distribution lines are properly fused to handle simultaneous peak activation of all four 2 A channels, preventing localized voltage dips that could trigger a CANopen communication drop or module reset.

Commissioning & Wiring Tips

To maintain the IP67 ingress protection rating, unused M12 and M8 ports must be sealed with Beckhoff-approved protective caps. Ensure the CANopen bus network is correctly terminated with a 120-Ohm resistor on the physical end-of-line module to mitigate signal reflections in long-distance bus runs.

Installation Guidelines

CRITICAL WARNING

Never connect or disconnect power, network, or field I/O connections while the control circuit is energized. Physical de-energization must be completed and verified before installation or replacement to prevent electrical arcing, module destruction, or field device failure.

1

Position the module on a flat machine structural surface and secure using the integrated structural mounting holes, taking care to avoid high-temperature zones.

2

Set the physical CANopen address and communication speed using the integrated rotary switches underneath the protective access cap.

3

Connect the network M12 cabling, routing shielded cables away from heavy variable frequency drives (VFDs) or electromagnetic noise sources.

4

Attach and secure all sensor and actuator lines to the M12 channels, ensuring all threaded collars are hand-tightened to seal the interfaces.

What is the maximum output current rating for each digital output on the IP2322-B510?

Each of the four digital outputs can support switching currents up to 2 A continuously, making them suitable for heavy-duty actuators.

Does this module support automatic CANopen baud rate detection?

No. The baud rate and the network Node ID are configured manually using the physical rotary switches located under the protective cap.

What connection style is used for the I/O channels?

The module uses standard M12 threaded circular industrial connectors to ensure secure and vibration-resistant wiring.

What is the signal input response filtering delay?

The digital inputs are equipped with a hardware-defined input filter time of 3 milliseconds to prevent false triggering from electrical noise.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...