  • Manufacturer: BECKHOFF

  • Product No.: KS4012

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 80g

  • Dimensions: 6.8 cm x 1.2 cm x 10.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Process control and automation networks requiring precise analog current loop signals utilize the Beckhoff KS4012 analog output terminal to interface with industrial actuators. This 2-channel analog output module delivers accurate signals in the range of 0 to 20 mA with a high-accuracy conversion resolution of 12 bits. The KS-series configuration features a pluggable wiring level, enabling rapid block installation, simplified maintenance, and field-pre-wiring without disconnecting individual signal lines. The module processes electrical analog current signals dynamically by converting digital values from the K-bus backplane with galvanic isolation, ensuring signal integrity in electrically noisy industrial environments.

Features

  • Two-channel analog outputs configured for standard 0 to 20 mA current loops.
  • High-resolution 12-bit digital-to-analog signal conversion.
  • Pluggable connection level (KS series design) for tool-free terminal replacement.
  • Galvanic isolation of 500 V between the K-bus and the analog process loop.
  • Compact 12 mm DIN rail housing to minimize control cabinet footprint.
  • Automatic data transfer across the K-bus with no address configuration required.

Applications

  • Proportional control valves and pneumatic actuators.
  • Speed references for variable frequency drives (VFD) and motor controllers.
  • Current-loop signal transmission in municipal water and wastewater systems.
  • Process heating loops and environmental chamber control.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model KS4012
Technology Single-ended
Number of Outputs 2
Power Supply 24 V DC via power contacts (alternative 15 V DC with power supply terminal KL9515)
Signal Current Range 0 to 20 mA
Load Resistance Less than 500 Ohm
Output Error Less than +/-0.1 % (relative to full scale end value)
Resolution 12 bit
Conversion Time Approx. 1.5 ms
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption (Power Contacts) Typ. 50 mA + load
Current Consumption (K-bus) Typ. 60 mA
Process Image Bit Width Output: 2 x 16 bit data (2 x 8 bit control/status optional)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, no condensation
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Housing Material Polycarbonate
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Weight 0.08 kg

Connections and Interfaces

Connection Parametric Specification / Range
Connection Technology Pluggable spring actuation by screwdriver
Solid Wire Cross-Section (s) 0.08 to 1.5 mm² (AWG 28 to 16)
Stranded Wire Cross-Section (st) 0.08 to 1.5 mm² (AWG 28 to 16)
Flexible Wire Cross-Section (f) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm
Power Contacts Current Load Imax: 10 A

Installation Guidelines

  • Mount the module onto a standard 35 mm DIN rail conforming to EN 60715. Use the integrated double slot and key lock for alignment with adjacent terminals.
  • Ensure the pluggable wiring level is fully clicked into position before applying field power.
  • Observe standard grounding practices for shielded current loop cabling to minimize high-frequency EMI.
  • Ensure a suitable IP54 minimum enclosure rating when installing within ATEX-certified Zone 2 hazardous areas.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • DNVGL

What is the key advantage of the KS4012 compared to the KL4012?

The KS4012 features a pluggable wiring connection level, allowing the terminal blocks to be quickly removed for maintenance without rewiring, whereas the KL4012 uses standard fixed terminals.

Does the KS4012 require manual address configurations?

No, the KS4012 requires no address or manual DIP switch configurations; it automatically maps its process image parameters via the K-bus backplane.

Can I power the KS4012 with a 15 V DC source?

Yes, while the standard power supply is 24 V DC via the power contacts, the KS4012 can be alternatively supplied with 15 V DC using a KL9515 power supply terminal.

What standard environmental protection rating does the KS4012 have?

The terminal is rated at IP20 and should be installed within a control cabinet or protective enclosure.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizace HMI Bailey INFI 90 Symphony běžících na OpenVMS Alpha

Praktický průvodce výměnou zastaralých operátorských stanic Bailey Symphony běžících na OpenVMS Alpha. Porovnává emulaci Alpha, migraci OpenVMS na x86, přemostění OPC a postupnou modernizaci ABB.

Proč jsou údaje o údržbě nezbytné pro průmyslovou spolehlivost

Údaje o údržbě propojují pracovní příkazy, signály ze senzorů, historii majetku, náklady a znalosti techniků. Správné využití těchto dat zlepšuje plánování, spolehlivost, prediktivní údržbu, kontrolu...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...