1 z 3

Bently Nevada 170180-02-00 FieldMonitor External Transducer I/O Module

Bently Nevada 170180-02-00 FieldMonitor External Transducer I/O Module

Only 7 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 170180-02-00

  • Country of origin:United States

  • Product Type: I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 277g

  • Dimensions: 45 mm x 120 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The Bently Nevada 170180-02-00 is an external transducer I/O module designed for use with the FieldMonitor machinery protection system. The 170180-02-00 connects 2-wire velocity transducers to their respective 2-channel monitoring module within the FieldMonitor assembly. Occupying a single slot in a FieldMonitor terminal base, it provides signal routing and interface conditioning for two independent 2-wire velocity transducer inputs. This specific configuration features a dual velocity I/O module setup with Division 2 / Zone 2 hazardous area approval rating.

Features

  • Interfaces two independent 2-wire velocity transducer inputs to FieldMonitor monitoring modules
  • Occupies one slot in a FieldMonitor terminal base
  • Provides signal conditioning and routing for two transducer channels
  • Certified for Division 2 / Zone 2 hazardous areas

Applications

  • Machinery protection and condition monitoring for industrial rotating equipment
  • Vibration and velocity measurement integration for turbines, pumps, compressors, and motors
  • Signal expansion within Bently Nevada FieldMonitor terminal base systems

Ordering Information

Part Number Description
170180-02-00 FieldMonitor External Transducer I/O Module
02 Transducer Type: Dual Velocity I/O Module (Channel A: One 2-wire Velocity Transducer, Channel B: One 2-wire Velocity Transducer)
00 Approvals / Agency Option: Division 2/Zone 2

Technical Specifications

Parameter Category Specification Details
Manufacturer Bently Nevada
Part Number 170180-02-00
Signal Inputs Channel A: One 2-wire Velocity Transducer; Channel B: One 2-wire Velocity Transducer
Input Signal Voltage Range 0 to -Vt
Output Voltage Range 0 to -Vt
Frequency Response -5% at >25 kHz
Input Impedance 9.98 +/- 0.02 kOhm
Current Draw (Without Transducer) 2.0 mA maximum
Operating Temperature -34 degC to +85 degC (-30 degF to +185 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 100% condensing nonsubmerged from +7 degC to +85 degC (+45 degF to +185 degF) when connector is protected
Slot Requirement Occupies 1 slot in FieldMonitor terminal base
Weight 277 g (0.61 lb) typical

Installation Guidelines

  • Slot Placement: Insert the module into a dedicated slot within the FieldMonitor terminal base.
  • Transducer Wiring: Connect 2-wire velocity transducers to Channel A and Channel B terminals according to system wiring diagrams.
  • Environmental Protection: Ensure field connectors are properly mated and sealed to protect against humidity condensation.

Compliance and Certifications

  • Hazardous Area Approvals: Division 2 / Zone 2
Loading product navigation…

What sensor types can be connected to this I/O module?

This module is configured specifically to accept inputs from two 2-wire velocity transducers across Channel A and Channel B.

How many slots does the device occupy in the FieldMonitor system?

The module occupies a single slot in a FieldMonitor terminal base.

What is the operating temperature range for this module?

The operating temperature range is from -34 degC to +85 degC (-30 degF to +185 degF).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizace HMI Bailey INFI 90 Symphony běžících na OpenVMS Alpha

Praktický průvodce výměnou zastaralých operátorských stanic Bailey Symphony běžících na OpenVMS Alpha. Porovnává emulaci Alpha, migraci OpenVMS na x86, přemostění OPC a postupnou modernizaci ABB.

Proč jsou údaje o údržbě nezbytné pro průmyslovou spolehlivost

Údaje o údržbě propojují pracovní příkazy, signály ze senzorů, historii majetku, náklady a znalosti techniků. Správné využití těchto dat zlepšuje plánování, spolehlivost, prediktivní údržbu, kontrolu...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...