1 z 1

Mitsubishi Electric FR-A840-00170-2-60 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-00170-2-60 FR-A800 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A840-00170-2-60

  • Country of origin:United States

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 8000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Designed for precision speed and torque control in heavy industrial environments, the Mitsubishi Electric FR-A840-00170-2-60 is a high-performance three-phase variable frequency drive belonging to the premium FR-A800 series. This standard model operates on a 400V class input and is engineered with an SLD (Super Light Duty) rated current rating of 17 A. To ensure long-term reliability in harsh operational environments, the unit features a specialized protective conformal circuit board coating (Class 3C2) without plated conductors, providing superior resistance to corrosive gases and moisture. Its robust cooling system relies on forced air circulation to maintain optimal thermal conditions inside enclosed electrical cabinets.

Features

  • Advanced Real Sensorless Vector Control and Vector Control capabilities for precise speed and torque regulation.
  • Specially coated circuit boards (conforming to IEC 60721-3-3 Class 3C2) for enhanced environmental resistance.
  • Dual-loop PID control and built-in PLC functionality to handle localized automation sequences.
  • Flexible overload capacity modes enabling optimization for various industrial load profiles.
  • Integrated safety stop function complying with EN ISO 13849-1 Category 3 / PLd and IEC 60204-1.
  • Forced air cooling system designed with long-life cooling fans for minimized maintenance overhead.

Applications

  • Conveyor Systems: Precise speed control and torque limits for high-inertia material handling applications.
  • Pumping and Ventilation: Energy-efficient flow control and pressure regulation using integrated PID algorithms.
  • Extruders and Mixers: High starting torque capabilities and excellent speed stability under fluctuating loads.
  • Hoists and Cranes: Smooth mechanical brake sequencing and load-torque matching routines.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number FR-A840-00170-2-60
Series FR-A800
Voltage Class Three-phase 400V class
Rated Input AC Voltage/Frequency Three-phase 380 to 500V AC, 50Hz / 60Hz
Permissible AC Voltage Fluctuation 323 to 550V AC, 50Hz / 60Hz
SLD Rated Inverter Current 17.0 A
Conformal Board Coating Standard 3C2 coating (conforms to IEC 60721-3-3)
Plated Conductor None
Protective Structure IP20 (Enclosed type)
Cooling System Forced air cooling
Unit Net Weight 6.7 kg
Shipping Weight (Calculated) 8.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

This model serves as a modern replacement for the legacy FR-A740 series. While physical footprint changes are minor, the control terminal layout is optimized. Parameter configurations from older FR-A740 units can be seamlessly imported using the FR Configurator2 software utility. Always check terminal strip physical spacing if replacing an older generation drive inside a tight control panel.

Application Pitfalls & Engineering Notes

The -60 suffix specifies a 3C2 conformal board coating. This is highly recommended for wastewater, pulp and paper, or chemical processing sites. However, because this model is designed without plated conductors, it should not be exposed to severe atmospheric concentrations of chlorine or sulfur salts that exceed Class 3C2 specs. If operating under high ambient temperatures, thermal derating curves must be applied to prevent overtemperature faults (E.THT).

Commissioning & Wiring Tips

Always ensure that control signals are isolated from high-power cable runs. Keep control and power cables in separate wire trays or use shielded cables grounded at the drive end only. False ground fault trips (E.GF) can occur if leakage currents from long motor cable runs exceed the threshold; installing an output dV/dt filter or a common-mode choke will mitigate this issue during commissioning.

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK AND EQUIPMENT DAMAGE. Ensure all main AC power sources are completely disconnected, locked out, and tagged out before installing or servicing this drive. Wait at least 10 minutes after disconnecting power to allow the DC bus capacitors to fully discharge. Verify zero voltage across terminals P/+ and N/- before touching any electrical terminals.
1
Enclosure Mounting: Mount the inverter vertically on a flat, non-flammable surface inside an IP20 or higher enclosure. Ensure minimum clearance distances (50 mm above and below, 10 mm on sides) to facilitate unobstructed airflow through the cooling heatsinks.
2
Power Input and Output Wiring: Connect the three-phase AC mains supply to terminals R/L1, S/L2, and T/L3. Connect the motor leads to terminals U, V, and W. Under no circumstances should input mains power be connected to the output terminals U, V, or W, as this will destroy the internal IGBT modules.
3
Grounding Connection: Connect the ground terminal of the drive securely to the system PE (Protective Earth) ground. Ground resistance must be 10 Ohms or less for 400V class installations to satisfy both safety standards and high-frequency noise suppression demands.

What does the -60 suffix mean for this inverter?

The -60 suffix indicates that the control and power circuit boards are treated with a conformal coating conforming to IEC 60721-3-3 Class 3C2, and it does not feature plated conductors.

What is the recommended grounding practice to prevent leakage current trips?

Ensure a dedicated Class D ground wire is connected directly to the inverter grounding terminal. Avoid loop configurations with other equipment to suppress high-frequency common-mode noise.

Can parameters from an older FR-A740 model be imported?

Yes, using FR Configurator2 software, you can convert and import parameter files from older FR-A700 series drives directly into this FR-A800 series unit.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...