1 z 1

Schneider ATV312HU40M3 Altivar 312 Variable Frequency Drive

Schneider ATV312HU40M3 Altivar 312 Variable Frequency Drive

Only 8 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATV312HU40M3

  • Country of origin:France

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 2900g

  • Dimensions: 14,20cm x 18,40cm x 15,20cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The ATV312HU40M3 is a compact variable frequency drive from the Schneider Electric Altivar 312 series, designed for general-purpose motor control applications. This drive operates within a 200-240V supply voltage range for 3-phase systems and is capable of managing motor power up to 4 kW with a rated output current of 17.5 A. Engineered to improve process efficiency, it provides precise control over motor speed and torque, helping to reduce energy consumption and mechanical strain in industrial environments.

Features

  • Compatible with 200-240V 3-phase power systems
  • Rated power capacity: 4 kW
  • Rated operational current: 17.5 A
  • Compact design for optimized cabinet space utilization
  • Designed for general-purpose industrial automation

Applications

  • Conveyor systems
  • HVAC units and ventilation systems
  • Manufacturing process machinery
  • Industrial pump and fan control
  • Material handling equipment

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altivar 312
Product Type Variable frequency drive
Rated Power 4 kW
Rated Current 17.5 A
Operating Voltage 200-240 V (3-phase)
Dimensions 14.20 x 18.40 x 15.20 cm
Weight 2.90 kg
Product Status Phase-Out
Commodity Code 85044095

Installation Guidelines

  • Mounting: Install the drive in a vertical position on a stable, non-flammable surface to facilitate proper airflow through the cooling channels.
  • Environment: Ensure the unit is installed in an environment free from conductive dust, corrosive gases, and extreme humidity to prevent component failure.
  • Clearance: Maintain the recommended minimum distances around the unit to ensure adequate heat dissipation and prevent thermal overload.
  • Wiring: Use appropriately rated cables for input and motor output connections, adhering to local electrical safety standards.
  • Grounding: Secure a reliable protective earth connection to the drive chassis to ensure operator safety and EMC performance.

What is the power rating of the ATV312HU40M3?

This drive is rated for a capacity of 4 kW.

What are the input voltage requirements for this VFD?

The drive operates on a 200-240V 3-phase power supply.

What is the rated output current for this model?

The rated operational current for the ATV312HU40M3 is 17.5 A.

What does the phase-out status imply?

The product status is marked as Phase-Out, meaning it may be replaced by newer generations or subject to limited availability; it is recommended to check for current stock or replacement series.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...