Allen-Bradley 1761-NET-AIC AIC+ Advanced Interface Converter

Allen-Bradley 1761-NET-AIC AIC+ Advanced Interface Converter

Nur noch 5 Artikel auf Lager verfügbar
  • Hersteller: Allen-Bradley

  • Produkt-Nr.: 1761-NET-AIC

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Communication Converters

  • Strichcode: 8537101190

  • Zahlung: T/T, Western Union

  • Gewicht: 200g

  • Abmessungen: 5cm x 7cm x 12.5cm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Anzahl
Vollständige Details anzeigen

The Allen-Bradley 1761-NET-AIC is a high-performance AIC+ advanced interface converter engineered to provide a reliable, isolated electronic communication link between various networked automation components. Operating as an intelligent protocol and physical layer adapter, the module features built-in electrical isolation to establish point-to-point or multidrop routing across diverse serial networks without risking ground loop faults. By utilizing dual RS-232 pathways combined with a dedicated RS-485 port interface, this device smoothly links controllers, personal computer configurations, operator terminals, and modems across demanding shop floor networks.

Features

  • Triple Port Interface: Integrated architecture offering one RS-485 Phoenix plug connection, an 8-pin mini-DIN RS-232 port, and a conventional 9-pin DB-9 DTE RS-232 communication port.
  • Comprehensive Electrical Isolation: Delivers 500V DC internal electrical isolation boundary limits between all communication ports and the active power supply terminals.
  • Flexible Operational Clocking: Built-in communication-rate selector switch supports distinct transmission steps including 1200, 2400, 4800, 9600, 14400, and 19200 bps, alongside an automated AUTO position mode.
  • Adaptable Power Sourcing: Built-in DC power-source selector switch allows the module to extract active power directly from a connected MicroLogix controller or use external 24V DC auxiliary block terminals.
  • Industrial Networking Range: Extends a standard DH-485, DF1, or user network multidrop segment up to 1219 m (4000 ft) with a total allowance of up to 32 nodes per network link.

Applications

  • Multidrop DH-485 or DF1 industrial network extensions connecting modular SLC 500 and compact MicroLogix controller nodes.
  • Isolation interfaces between local supervisory computer workstations (PC serial COM ports) and high-voltage factory networks.
  • Distributed multi-node configurations linking remote PanelView operator graphic terminals to distributed control backplanes.

Technical Specifications

Attribute Value / Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number 1761-NET-AIC
Module Type AIC+ Advanced Interface Converter
24V DC Power Source Requirement 20.4 to 28.8V DC
Current Draw 0 to 120 mA
Inrush Current (Max.) 200 mA
Internal Isolation 500V DC between all ports and power supply terminals
Supported Network Protocols DH-485, DF1, or User Network ASCII
Max. Nodes per Multidrop Link 32 nodes
Max. Network Length 1219 m (4000 ft) per multidrop network
Max. Ganged Multidrop Networks 2
Communication Rates 1200, 2400, 4800, 9600, 14400, 19200 bps and AUTO
Operating Ambient Temperature 0 to 60 degC (32 to 140 degF)
Storage Temperature -40 to 85 degC (-40 to 175 degF)
Country of Origin U.S.A.

Connections and Interfaces

Interface Port Description / Assignment
RS-485 Port (Phoenix Plug) Terminal 1: Chassis Ground | Terminal 2: Shield | Terminal 3: Common | Terminal 4: B | Terminal 5: A | Terminal 6: Termination
RS-232 Port (8-pin mini-DIN) Primary communication connection designed to interface with MicroLogix controllers; capable of drawing internal operational power.
RS-232 Port (DB-9, DTE) Standard 9-pin serial layout matching personal computer COM channels, PanelView graphic units, modems, or alternative DTE lines.
External Power Terminals Screw block connection points for dedicated auxiliary external 24V DC supply lines and structural ground wire runs.

Installation Guidelines

ATTENTION: EXPLOSION HAZARD. Substitution of components may impair suitability for Class I, Division 2 environments. Do not replace components or disconnect equipment unless power has been switched off or the installation area is known to be nonhazardous. Do not operate switches or mating cables while the circuit is live.
1

Enclosure Selection: Install the interface converter inside a protective industrial enclosure. All interconnecting data cables must remain housed within the enclosure or be shielded using rigid electrical conduit.

2

DIN Rail Assembly: Snap the converter housing directly onto a standardized top-hat style DIN rail channel, or mount it securely to a backpanel plane using the integrated mounting feet holes.

3

Power Switch Selection: Position the DC power-source selector switch before activating the lines. Set the switch to EXTERNAL when using independent 24V DC terminal feeds, or set it to CABLE if deriving internal power directly from a MicroLogix 8-pin mini-DIN cable.

4

RS-485 Cable Termination: For end-of-line nodes on a daisy-chained RS-485 trunk line using Belden #3106A or #9842 cable, connect a short wire jumper between Terminal 1 (Chassis Ground) and Terminal 2 (Shield) on one end to provide a single, secure earth path.

5

Baud Rate Optimization: Keep the communication-rate selector switch set to the AUTO position for standard installations. In environments with severe electromagnetic noise or interference, switch it to manual and set it to match the exact fixed baud rate of the network.

Compliance and Certifications

  • UL 1604 Standard
  • C-UL C22.2 No. 213
  • Class I, Division 2, Groups A, B, C, D Hazardous Locations
  • CE Compliant (Council Directive 89/336/EEC EMC / Council Directive 73/23/EEC Low Voltage)
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1761-NET-AIC AIC+ Advanced Interface Converter

Loading PDF, please wait…

When is an external 24V DC power supply required for this converter?

An external power supply is mandatory in Class I, Division 2 hazardous locations, or in configurations where the 8-pin mini-DIN port is not connected directly to a power-providing MicroLogix controller.

Can the 1761-HHP-B30 Hand-Held Programmer be used with this module?

No. The 1761-HHP-B30 Hand-Held Programmer cannot be connected to or used through the advanced interface converter.

What is the purpose of the internal 500V DC isolation boundary?

The 500V DC isolation safe zone protects connected components from electrical noise, voltage transients, and dangerous ground loops across conflicting communication networks and power line systems.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) eingehen.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabebedingungen lesen Sie bitte unsere offiziellen Rückerstattungs- & Rückgaberecht .

TECHNICAL SPECIFICATIONS

Color pattern
Beige Grauweiß
Country of origin
Vereinigte Staaten
Power source
Gleichstromversorgung

Kürzlich angesehene Produkte

Technisches Wissen

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Die boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...