1 von 1

Beckhoff IL2300-C310 Fieldbus Box PLC Box

Beckhoff IL2300-C310 Fieldbus Box PLC Box

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: IL2300-C310

  • Herkunftsland:Deutschland

  • Produkttyp: PLC Box Modules

  • Zahlung: T/T, Western Union

  • Gewicht: 500g

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Decentralized signal routing in demanding automated environments is managed directly at the machine level by the Beckhoff IL2300-C310, a rugged PROFIBUS DP fieldbus PLC Box. Engineered to bypass the need for protective control cabinets, this module features a highly resilient IP67 housing and handles communications using standard physical media profiles. Crucial system setups and configuration modifications are achieved easily using the KS2000 software utility or directly via control-level parameters. It supports DP-V1 extensions for enhanced diagnostics, making it an efficient choice for complex topology architectures requiring distributed industrial intelligence.

Features

  • Automatic Baud Rate Detection: Detects and locks onto incoming bus transfer rates automatically up to 12 Mbaud.
  • DP-V1 Extension Support: Allows acyclic data transfer for advanced configuration, parameterization, and diagnostic feedback.
  • Robust Environmental Hardening: Rated for IP65, IP66, and IP67 industrial environments, protecting against dust ingress and high-pressure water jets.
  • Compact Standardized Footprint: Designed for direct machine frame mounting, minimizing cable runs and panel space.
  • Standardized Connector Layout: Utilizes standard M12 and M8 circular industrial connectors to simplify replacement and installation cycles.

Applications

  • Automated manufacturing and robotic assembly lines requiring distributed node architectures.
  • Packaging machineries, high-vibration systems, and materials handling conveyors.
  • Wet areas and washdown environments such as food processing facilities or chemical dosing systems.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Identifier IL2300-C310
Bus Interface 1 x M12 socket, 5-pin, B-coded
Data Transfer Rates Automatic detection up to 12 Mbaud
Configuration Options Via KS2000 configuration software or PLC controller
Control Voltage 24 V DC (-15% / +20%)
Load Voltage According to I/O type specification
Internal Current Draw (Box) 85 mA + current consumption of sensors (max. 0.5 A)
Power Feed Connection 1 x M8 male connector, 4-pin
Power Downstream Link 1 x M8 female socket, 4-pin
Electrical Isolation Control voltage/fieldbus: none; Control/Inputs or Outputs: By I/O type
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Ingress Protection Rating IP65/66/67 (conforms to EN 60529)
Shock and Vibration Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Standards Conforms to EN 61000-6-2 / EN 61000-6-4
Certifications CE, UL
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector Type Pin Count / Coding Standard Purpose
Bus Interface (In/Out) 5-pin, B-coded M12 socket Primary PROFIBUS DP network connection segment
Power Feed Input 4-pin, M8 male plug Incoming 24 V DC control voltage and logic feed
Power Link Output 4-pin, M8 female socket Downstream daisy-chain distribution of 24 V DC system power

Empirical Engineering Insights

Alternative Models & Compatibility

When integrating the IL2300-C310 into older system architectures, ensure that your master GSD database matches the hardware revision of the box. Although it serves as a direct drop-in functional unit for legacy decentralized PROFIBUS modules, check software support within TwinCAT 2.x or 3.x configuration profiles to guarantee appropriate addressing offsets for complex I/O topologies.

Application Pitfalls & Engineering Notes

Keep in mind that while the module carries robust sealing specs (IP67), local heat accumulation inside dense non-ventilated mounting locations can shorten the operational lifespan of the unit. Ensure adjacent heat-producing equipment is sufficiently spaced. Avoid exceeding the maximum sensor pass-through current of 0.5 A; attempting to power multiple heavy-duty sensors off a single branch daisy-chained feed will trigger overcurrent conditions.

Commissioning & Wiring Tips

Always use high-quality, pre-assembled M12 PROFIBUS cables to prevent impedance mismatch at high Mbaud rates. If the communication interface behaves erratically, check for proper termination. Active termination should be used at both physical ends of the PROFIBUS network segment. Torque M8 and M12 connectors properly to keep moisture out of unused pins.

Installation Guidelines

CRITICAL WARNING: Disconnect all electrical feeds before carrying out any mounting or termination procedures. Ensure control lines and load power sources are locked out to prevent accidental power-up. Wait for stored electrostatic charges in downstream line capacitors to dissipate fully before handling wiring harnesses.
1
Mount the IL2300-C310 physically to a flat, rigid substrate using standard M4 screws. Avoid applying excessive structural tension to the plastic casing.
2
Connect the 5-pin, B-coded M12 PROFIBUS input line to the designated interface, ensuring the pins align smoothly before tightening the knurled collar.
3
Attach the M8 24 V DC power feed cable. Screw downstream power linkages securely into place, and cover any empty ports with protective dust caps.
Loading product navigation…

What is the maximum pass-through sensor current supported by the IL2300-C310?

The internal control electronics draw 85 mA, and the maximum pass-through current available for connected sensors is strictly limited to 0.5 A.

How does the module handle communication speed configuration?

It features integrated automatic baud rate detection, which matches and locks onto the controller's PROFIBUS DP clock rate up to 12 Mbaud.

What software is used to configure the IL2300-C310?

Configuration, parameter changes, and diagnostic profiles can be completed using the Beckhoff KS2000 utility or directly from the master PLC controller.

Does this model have integrated active PROFIBUS line termination?

No, it does not feature built-in active termination. External termination resistors or modules must be used at the end of physical PROFIBUS runs.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...