Acquisition of analog sensor signals within automated industrial networks is performed efficiently using the BECKHOFF KS3142 analog input terminal. This high-precision Bus Terminal provides dual-channel connection capabilities for field sensors operating with standard 0 to 20 mA signal currents. Utilizing a robust differential input design and a 16-bit analog-to-digital converter, the module delivers highly accurate measurement data directly to the K-bus process image. The distinctive feature of the KS-series housing is its pluggable wiring level, which enables fast assembly and easy replacement of the terminal block without disconnecting the established field-side wire connections.

Features

  • Two-channel analog input module processing 0 to 20 mA field signals.
  • High-resolution 16-bit analog-to-digital conversion with increased measuring accuracy.
  • Configurable conversion time and integral 50 Hz filter to eliminate signal noise.
  • Pluggable connection level allows quick terminal swapping during maintenance operations.
  • Differential inputs with 500 V galvanic isolation between the K-bus and field signals.
  • Integrated surge voltage resistance up to 35 V DC for enhanced field protection.

Applications

  • Machine building and precision assembly equipment
  • Industrial process instrumentation loops
  • Water and wastewater treatment facility monitoring
  • Power generation and thermodynamic plant controls

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model KS3142
Number of Inputs 2
Power Supply Via the K-bus
Signal Current 0 to 20 mA
Technology Differential input
Internal Resistance typ. 100 Ohm shunt
Common-mode Voltage (UCM) max. +/-10 V
Resolution 16 bit
Conversion Time 140 ms (configurable)
Filter 50 Hz (configurable)
Measuring Error < +/-0.05% (relative to full scale value)
Surge Voltage Resistance 35 V DC
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus typ. 85 mA
Bit Width in Process Image Input: 2 x 16-bit data (2 x 8-bit control/status optional)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Wiring Type Spring actuation by screwdriver (pluggable connector)
Connection Cross-section Solid/stranded: 0.08 to 1.5 mm², Fine-wire: 0.14 to 1.5 mm²
Connection Cross-section AWG Solid/stranded: AWG 28 to 16, Fine-wire: AWG 26 to 16
Stripping Length 9 to 10 mm
Current Load Power Contacts Imax: 10 A
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Weight 0.07 kg

Installation Guidelines

  • Mounting: Snap directly onto a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking latch engages securely.
  • Wiring: Insert a small screwdriver into the clamp spring release slot to open the connection point, insert the stripped conductor (9 to 10 mm stripping length), and release the spring clamp.
  • Pluggable Block: Ensure the power supply is completely switched off before engaging or disengaging the pluggable terminal wiring block.
  • Shielding: Connect analog signal shields to the nearest functional ground bar to prevent environmental electromagnetic interference from affecting signal integrity.

Compliance and Certifications

  • CE
  • UL
  • ATEX
  • Ex Marking: II 3 G Ex nA IIC T4 Gc
Loading product navigation…

What is the key advantage of the KS3142 pluggable wiring design?

The pluggable terminal block on the KS3142 allows the core unit to be unplugged and replaced during maintenance without having to disconnect or tag the individual signal lines.

Can the conversion times and filters of the KS3142 be adjusted?

Yes, both the conversion time (default 140 ms) and the internal 50 Hz filter parameters can be configured through the bus coupler software settings.

Does the KS3142 have standard ATEX ratings for hazardous locations?

Yes, the module is certified under ATEX with the Ex marking: II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...