1 von 1

BECKHOFF KS3444 Bus Terminal 4-Channel Analog Input Module

BECKHOFF KS3444 Bus Terminal 4-Channel Analog Input Module

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: KS3444

  • Herkunftsland:Deutschland

  • Produkttyp: Bus Terminals

  • Zahlung: T/T, Western Union

  • Gewicht: 55g

  • Abmessungen: 12 mm x 100 mm x 68 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Industrial processing systems utilize the BECKHOFF KS3444 analog input bus terminal to interface standard 0 to 20 mA signals directly from the field level to the higher-level automation controller. This four-channel module features single-ended inputs and provides a highly space-efficient design with a pluggable wiring level, enabling fast, tool-free installation and maintenance. By operating directly through the standard K-bus, the unit transmits digitized process values back to the coupler or controller with a 12-bit resolution. Integrated electrical isolation of 500 V between the K-bus and the signal channels guarantees high noise immunity and signal integrity in demanding electrical environments.

Features

  • Four single-ended analog inputs handling standard 0 to 20 mA current loops.
  • Pluggable connection level (KS-series design) allowing pre-wiring and rapid terminal replacement.
  • Compact 12 mm housing width to optimize control cabinet and DIN rail space.
  • K-bus powered with a typical current consumption of 85 mA.
  • Reliable performance across a broad operating temperature range of 0 to +55 degC.
  • Sturdy design complying with EN 60068-2-6 and EN 60068-2-27 for vibration and shock resistance.

Applications

  • Chemical and petrochemical processing plants.
  • Water and wastewater treatment facilities.
  • Machinery manufacturing and factory automation.
  • HVAC and building automation controls.

Technical Specifications

CategoryTechnical ParameterValue
Manufacturer BECKHOFF KS3444
Product Type Bus Terminal (Pluggable wiring level) 4
Signal Current 0 to 20 mA Single-ended
Internal Resistance < 85 Ohm 12 bit
Conversion Time approx. 2 ms < ±0.3 % (relative to full scale value)
Surge Voltage Resistance 30 V DC 500 V (K-bus/signal voltage)
Current Consumption K-Bus typ. 85 mA Input: 4 x 16 bit data (4 x 8 bit control/status optional)
Housing Material Polycarbonate IP20 / variable
Operating Temperature 0 to +55 degC -25 to +85 degC
Relative Humidity 95 %, non-condensing Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4 35 mm DIN rail (EN 60715) with lock
Connection Cross-section Solid/Stranded: 0.08 to 1.5 mm²; Fine-wire: 0.14 to 1.5 mm² AWG 28 to 16 (Solid/Stranded); AWG 26 to 16 (Fine-wire)
Stripping Length 9 to 10 mm 12 mm x 100 mm x 68 mm
Weight 0.055 kg II 3 G Ex nA IIC T4 Gc

Connections and Interfaces

Connection Point Signal Assignment
Terminal 1 Input 1 (+)
Terminal 2 Input 2 (+)
Terminal 3 Input 3 (+)
Terminal 4 Input 4 (+)
Terminal 5 Input 1 (0 V)
Terminal 6 Input 2 (0 V)
Terminal 7 Input 3 (0 V)
Terminal 8 Input 4 (0 V)

Installation Guidelines

  • Mount the terminal on a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking mechanism is securely engaged.
  • To wire the pluggable KS terminal, use a flat-bladed screwdriver to actuate the integrated tension clamp mechanism.
  • Ensure the system power supply is deactivated before plugging or unplugging the terminal wiring block to prevent damage to the K-bus connections.
  • Observe regional grounding and shielding guidelines for analog signal cables to minimize electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX (II 3 G Ex nA IIC T4 Gc)
  • DNVGL
Loading product navigation…

What is the primary difference between the Beckhoff KL3444 and the KS3444?

The KS3444 features a pluggable wiring level, allowing the terminal block connector to be detached from the main housing without disconnecting individual field wires. The KL3444 has a fixed wiring level.

Does the KS3444 require an external power supply for K-bus communication?

No, the KS3444 is powered directly via the K-bus backplane from the bus coupler or controller, drawing a typical current of 85 mA.

Is the Beckhoff KS3444 suitable for hazardous locations?

Yes, the KS3444 is ATEX certified with Ex marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas when installed in an appropriate enclosure.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...