1 von 1

BECKHOFF KS4434 Bus Terminal

BECKHOFF KS4434 Bus Terminal

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: KS4434

  • Herkunftsland:Deutschland

  • Produkttyp: Analog Output Modules

  • Zahlung: T/T, Western Union

  • Gewicht: 75g

  • Abmessungen: 12 mm x 100 mm x 68 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Engineered for precise analog automation control, the BECKHOFF KS4434 analog output terminal delivers four channels of high-resolution control signals. Operating within a standard range of -10 to +10 V, this bus terminal features single-ended circuitry designed to drive analog actuators, control valves, and speed-controlled motor drives with precision.

A defining feature of the KS series is its pluggable wiring level, enabling fast, tool-free module replacement without disrupting existing system wiring. Integrating seamlessly into the Beckhoff K-bus system, the module transmits electrically isolated signals back to the automation controller, maintaining process stability and protecting sensitive upstream components from electrical noise.

Features

  • Four single-ended analog output channels.
  • Standard bipolar voltage signal range of -10 to +10 V.
  • 12-bit analog resolution for fine control loop adjustments.
  • Pluggable connection level for swift, minimized-downtime maintenance.
  • Short-circuit proof outputs with active load protection above 5 kOhm.
  • Robust electrical isolation rated up to 500 V between K-bus and signal circuits.
  • Direct DIN rail installation with reliable double-slot side-by-side locking.

Applications

  • Industrial machinery and process control systems.
  • Variable frequency drive speed setting regulation.
  • Proportional valve control in hydraulic and pneumatic systems.
  • HVAC ventilation, damper, and actuator positioning.
  • OEM manufacturing lines and assembly automation.

Technical Specifications

System & Electrical Parameters
Manufacturer BECKHOFF
Part Number / Model KS4434
Number of Outputs 4
Signal Voltage Range -10 to +10 V
Output Load > 5 kOhm (short-circuit proof)
Output Error < +/-0.1 % (relative to full-scale value)
Resolution 12 bit
Conversion Time ~ 4 ms
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus Typ. 20 mA
Process Image Bit Width Output: 4 x 16-bit data (optional 4 x 8-bit control/status)
Current Load Power Contacts Max. 10 A
Mechanical & Environmental Data
Connection Technology Spring actuation (tension clamp)
Solid Wire Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Fine-Strand Wire Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.075 kg
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with lock
Operating Temperature 0 to 55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20

Installation Guidelines

  • Mounting: Mount the bus terminal horizontally or vertically on a standard 35 mm DIN rail. Secure the terminal using the integrated lock mechanism.
  • Wiring: Use a flat-blade screwdriver to open the spring clamp terminal. Insert the stripped wire (9 to 10 mm stripping length) and release the clamp.
  • Shielding & Grounding: Ensure the analog signal cables are properly shielded to prevent electromagnetic interference from surrounding power circuits. Connect the shield to the ground plane closest to the entry point.
  • Pluggable Level: When servicing, slide the pluggable terminal connector out of the housing to disconnect wiring safely without terminal-by-terminal rewiring.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • DNV GL
Loading product navigation…

What is the key advantage of the BECKHOFF KS series over the standard KL series?

The KS series, including the KS4434, features a pluggable wiring level. This allows the terminal housing to be pulled out and replaced without disconnecting the field wiring, reducing maintenance time.

What signal range does the BECKHOFF KS4434 analog output terminal use?

The KS4434 outputs a bipolar voltage signal ranging from -10 V to +10 V.

Does the KS4434 require manual address configuration?

No, the KS4434 does not require manual address or hardware configuration settings; it is automatically mapped into the system's process image.

Is the analog output protected against short circuits?

Yes, the analog outputs are short-circuit proof with an active load protection recommended above 5 kOhm.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe als Ersatz für Flüssigkeiten: Praktisches Tutorial

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...