Nur noch 8 Artikel auf Lager verfügbar
  • Hersteller: General Electric

  • Produkt-Nr.: IS230SNRLH2A

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Discrete Output Module

  • Strichcode: 8537101190

  • Zahlung: T/T, Western Union

  • Gewicht: 1200g

  • Abmessungen: 160 mm x 180 mm x 110 mm (W x H x D)

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

The IS230SNRLH2A operates as a discrete output module within the Mark VIe control platform series. This assembly is built from an IS200SRLY terminal board coupled with a PDOA I/O pack to deliver remote switching capability. The component provides 12 form C relay output circuits deployed across 48 pluggable-type physical terminals. To customize functional capabilities, the module can interface with auxiliary option boards including the IS200WROB, IS200WROF, and IS200WROG boards via integrated mating connectors. For example, integrating the IS200WROF alternative introduces an individual serial fuse protective link onto every single relay common trace alongside discrete fuse voltage feedback loops, accommodating either AC or DC external wetting voltages across the switching circuitry.

Features

  • Provides 12 form C relay output contact loops routed across a 48-terminal wiring field.
  • Combines an internal IS200SRLY board assembly and a PDOA processing pack into one component.
  • Includes dedicated board connectors to interface with IS200WROB, IS200WROF, or IS200WROG option expansion units.
  • Supports broad flexibility by routing either AC or DC incoming wetting voltage vectors through selective option board attachments.

Applications

  • Mark VIe Gas and Steam Turbine Controls: Directing industrial field relay excitation and automated valve execution paths.
  • Simplex Redundant Digital Output Blocks: Providing clean contact sequencing hooks for general power distribution loops.
  • Isolated Interlocking Circuits: Interfacing process control instrumentation logs to auxiliary remote machinery cabinets.

Technical Specifications

Parameter Value
Manufacturer GE Energy
Part Number IS230SNRLH2A
Product Type Discrete Output Module
Series Mark VIe
I/O Pack Redundancy Simplex Redundant
I/O Packs Impacted PDOA Pack
Terminal Board Component IS200SRLY
A-Rated Revision Functional Rev
Input Signal Style Discrete
Relay Circuit Configuration 12 Form C Relays
Total Terminals 48 Terminals
Terminal Design Type Pluggable Type
Base Product Mounting DIN Rail
Estimated Weight 1.20 KG
Estimated Dimensions (W x H x D) 160 mm x 180 mm x 110 mm

 

Connections/Interfaces

Connector Type Function
48 Pluggable Terminals Provides direct wiring termination points for the 12 form C relay output channels
Option Board Connectors Structural interface links for connecting IS200WROB, IS200WROF, or IS200WROG boards

 

Installation Guidelines

  • Disconnect all control power feeds prior to snapping the base mounting housing onto the tracking carrier.
  • Align the module firmly onto the standard DIN rail track until the locking tabs latch completely into place.
  • Use pluggable terminal blocks to land field wires before inserting them into the terminal board frame.
  • Ensure option boards are properly aligned with the on-board connectors to establish solid electrical paths for the wetting lines.
Loading product navigation…

What primary boards compose the internal assembly of the device?

The device is composed of an internal IS200SRLY terminal board assembly mated to a PDOA processing I/O pack.

What type of electrical protection does the WROF option board provide when connected?

The WROF option board installs a single fuse in series with each individual relay common connection trace and provides additional fuse voltage feedback data.

What type of wiring contacts are accessible on the field terminal block?

The device provides a total of 12 form C relay output circuits accessed via 48 integrated pluggable terminal connection points.

Can the module accept alternative electrical potentials for its wetting circuits?

Yes, when configured with the compatible option boards, the incoming wetting potential can be supplied as either an AC or DC voltage source.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Color pattern
Schwarz
Country of origin
Vereinigte Staaten
Power source
Gleichstromversorgung

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...