1 von 1

Honeywell 900A16-0101 HC900 Analog Input Hi Level Module

Honeywell 900A16-0101 HC900 Analog Input Hi Level Module

Nur noch 3 Artikel auf Lager verfügbar
  • Hersteller: Honeywell

  • Produkt-Nr.: 900A16-0101

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Analog Input Modules

  • Zahlung: T/T, Western Union

  • Gewicht: 2000g

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Processing high-level analog signals within industrial automation networks requires reliable, high-density interfaces, which is precisely why the 900A16-0101 was engineered. This high-level analog input module provides 16 isolated channels designed for seamless integration with Honeywell HC900 process controllers. It efficiently monitors and converts analog voltage and current field signals into highly accurate digital data for system processing.

The module features a dedicated analog-to-digital converter, ensuring consistent and rapid update cycles across all channels. With robust point-to-point galvanic isolation and advanced noise rejection characteristics, the 900A16-0101 maintains signal integrity and protects sensitive control system logic from field-side electrical disturbances. This level of reliability makes it a critical component for continuous process control applications where signal precision is vital.

Features

  • 16 isolated high-level input channels to prevent ground loops and signal interference.
  • Supports multiple high-level input signal types including voltage (V) and current (mA).
  • Equipped with a high-resolution 15-bit analog-to-digital converter.
  • Rapid channel update times of 100ms for real-time monitoring.
  • Robust solid-state galvanic isolation rated at 400 VDC point-to-point and 1000 VDC to logic.
  • Superior noise rejection capabilities in both series and common modes.
  • High-impedance inputs minimizing loading effects on field transmitters.

Applications

  • Oil and gas refinery process monitoring.
  • Chemical processing and batch control.
  • Power generation and distribution systems.
  • Water and wastewater treatment facilities.
  • Industrial boiler and combustion control systems.

Technical Specifications

Manufacturer Honeywell
Part Number/Model 900A16-0101
Series HC900 Control System
Module Type Analog Input High Level Module
Number of Channels 16 (Isolated)
Input Types Voltage (V), Current (mA)
Input Impedance >1 megohm for voltage inputs, 250 ohms for current inputs
Galvanic Isolation 400 VDC point-to-point (solid-state switching); 1000 VDC to system logic
A/D Resolution ±15 Bits
Update Rate 100ms
Noise Rejection Series Mode: >31dB, Common Mode: >90dB at 120VAC
Over-range Limit ±10% for linear voltage ranges
Temperature Coefficient ±0.01% of full scale per Celsius maximum
Long-term Stability 0.1% per year
Shipping Weight 2.0 kg

Installation Guidelines

  • Mounting: Mount secure in the designated I/O slot of an HC900 controller rack or remote I/O chassis. Ensure rack power is switched off during insertion or removal.
  • Wiring & Shielding: Use twisted, shielded pair cables for all analog signal runs. Ground the shields at only one end (typically at the controller side) to prevent ground loops.
  • Conduit Layout: Separate low-voltage analog signal cables from high-voltage AC power distribution and motor control lines.
  • Thermal Management: Maintain adequate clearance around the controller rack to ensure convective cooling airflow is not obstructed.
Loading product navigation…

What types of input signals can the Honeywell 900A16-0101 module accept?

The module accepts high-level analog inputs including voltage (V) and current (mA) signals.

How many isolated channels are available on this module?

The 900A16-0101 features 16 isolated high-level analog input channels.

What is the point-to-point isolation rating of the 900A16-0101?

It provides 400 VDC point-to-point solid-state galvanic isolation and 1000 VDC isolation to system logic.

What is the update rate for the analog inputs?

The analog-to-digital converter updates all channels on the module every 100ms.

What is the input impedance of the 900A16-0101?

The input impedance is greater than 1 megohm for voltage inputs and 250 ohms for current (mA) inputs.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...